Systematic review with meta-analysis: Volatile organic compound analysis to improve faecal immunochemical testing in the detection of colorectal cancer

被引:21
|
作者
Chandrapalan, Subashini [1 ]
Bosch, Sofie [1 ]
Cubiella, Joaquin [1 ]
Guardiola, Jordi [1 ]
Kimani, Peter [1 ]
Mulder, Chris [1 ]
Persaud, Krishna [1 ]
de Meij, Tim G. J. [1 ]
Altomare, Donato F. [1 ]
Brenner, Herman [1 ]
de Boer, Nanne K. H. [1 ]
Ricciardiello, Luigi [1 ]
Arasaradnam, Ramesh P. [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire, Coventry, W Midlands, England
关键词
DIAGNOSTIC-ACCURACY; PRIMARY-CARE; BOWEL-DISEASE; HEMOGLOBIN; CALPROTECTIN; CUTOFF;
D O I
10.1111/apt.16405
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Faecal immunochemical test (FIT) is emerging as a valid test to rule-out the presence of colorectal cancer (CRC). However, the accuracy of FIT is dependent on the cut-off applied. An additional low-cost test could improve further detection of CRC. Aims To evaluate the efficacy of combined FIT and volatile organic compounds (VOC) in the detection of CRC within symptomatic populations. Methods Systematic reviews on the diagnostic accuracy of FIT and VOC, for the detection of CRC, were updated. Meta-analyses were performed adopting a bivariate model for sensitivity and specificity. Clinical utility of combined FIT and VOC was estimated using Fagan's nomogram. Post-test probability of FIT negatives was used as a pre-test probability for VOC. Results The pooled sensitivity and specificity of FIT at 10 mu g/g faeces, for the detection of CRC, were 0.914 (95% confidence interval [CI] = 0.894-0.936) and 0.783 (CI = 0.850-0.696), respectively. For VOC, the sensitivity was 0.837 (CI = 0.781-0.881) and the specificity was 0.803 (CI = 0.870-0.712). The area under the curve for FIT and VOC were 0.926 and 0.885, respectively. In a population with 5% CRC prevalence, the estimated probability of having CRC following a negative FIT was 0.5% and following both negative FIT and VOC was 0.1%. Conclusions In a FIT-negative symptomatic population, VOC can be a good test to rule-out the presence of CRC. The estimated probability reduction by 0.4% when both tests being negative offers adequate safety netting in primary care for the exclusion of CRC. The number needed to colonoscope to identify one CRC is eight if either FIT or VOC positive. Cost-effectiveness and clinical accuracy of this approach will need further evaluation.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 50 条
  • [1] Editorial: volatile organic compound analysis to improve faecal immunochemical testing in the detection of colorectal cancer
    Hanna, George B.
    Cross, Amanda J.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2021, 54 (04) : 504 - 505
  • [2] Editorial: volatile organic compound analysis to improve faecal immunochemical testing in the detection of colorectal cancer-Authors' reply
    Chandrapalan, Subashini
    Bosch, Sofie
    Tyagi, Heena
    Daulton, Emma
    Cubiella, Joaquin
    Guardiola, Jordi
    Kimani, Peter
    Mulder, Chris
    Covington, James
    Persaud, Krishna
    de Meij, Tim G. J.
    Altomare, Donato F.
    Brenner, Herman
    de Boer, Nanne K. H.
    Ricciardiello, Luigi
    Arasaradnam, Ramesh P.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2021, 54 (04) : 506 - 507
  • [3] EXHALED VOLATILE ORGANIC COMPOUNDS IN THE DETECTION OF COLORECTAL CANCER: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Alsaadi, Daniah
    Clements, Nicolle
    Gabuniya, Natiya
    Francis, Nader
    Chand, Manish
    EXCLI JOURNAL, 2024, 23 : 795 - 810
  • [4] A Systematic Review and Meta-Analysis: Volatile Organic Compound Analysis in the Detection of Hepatobiliary and Pancreatic Cancers
    Pelling, Melina
    Chandrapalan, Subashini
    West, Emily
    Arasaradnam, Ramesh P.
    CANCERS, 2023, 15 (08)
  • [5] Exhaled volatile organic compounds in the detection of colorectal cancer: A systematic seview and meta-analysis
    Alsaadi, Daniah
    Clements, Nicolle
    Gabuniya, Natiya
    Chand, Manish
    Nader, Francis
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [6] Colorectal cancer screening with faecal testing, sigmoidoscopy or colonoscopy: a systematic review and network meta-analysis
    Jodal, Henriette C.
    Helsingen, Lise M.
    Anderson, Joseph C.
    Lytvyn, Lyubov
    Vandvik, Per Olav
    Emilsson, Louise
    BMJ OPEN, 2019, 9 (10):
  • [7] Urinary volatile organic compounds for colorectal cancer screening: A systematic review and meta-analysis
    van Liere, Elsa L. S. A.
    van Dijk, Laura J.
    Bosch, Sofie
    Vermeulen, Louis
    Heymans, Martijn W.
    Burchell, George L.
    de Meij, Tim G. J.
    Ramsoekh, Dewkoemar
    de Boer, Nanne K. H.
    EUROPEAN JOURNAL OF CANCER, 2023, 186 : 69 - 82
  • [8] Systematic review and meta-analysis : diagnostic accuracy of faecal immunochemical testing for haemoglobin (FIT) in detecting colorectal cancer for both symptomatic and screening population
    Stonestreet, J.
    Chandrapalan, S.
    Woolley, D.
    Uthman, O.
    Arasaradnam, R. P.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2019, 82 (02) : 291 - 299
  • [9] Accuracy of Fecal Immunochemical Tests for Colorectal Cancer Systematic Review and Meta-analysis
    Lee, Jeffrey K.
    Liles, Elizabeth G.
    Bent, Stephen
    Levin, Theodore R.
    Corley, Douglas A.
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 171 - +
  • [10] Effect of anticoagulants and NSAIDs on accuracy of faecal immunochemical tests (FITs) in colorectal cancer screening: a systematic review and meta-analysis
    Nieuwenburg, Stella A. V.
    Vuik, Fanny E. R.
    Kruip, Marieke J. H. A.
    Kuipers, Ernst J.
    Spaander, Manon C. W.
    GUT, 2019, 68 (05) : 866 - 872