Investigation of the in-vitro loading on an artificial spinal disk prosthesis

被引:1
|
作者
Kyriacou, P. A. [1 ]
Pancholi, M. P. [1 ]
Yeh, J. [1 ]
机构
[1] City Univ London, Sch Engn & Math Sci, London, England
来源
关键词
LUMBAR SPINE; COMPRESSION;
D O I
10.1088/1742-6596/178/1/012023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spinal diseases imposes considerable burden to both patients and society. In recent years, much surgical efforts have been made in advancing the treatment of neck and back pain. Of particular prominence is the increasing clinical acceptance and use of intervertebral artificial disk prosthesis for the treatment of discogenic back pain. Despite this increased use of such disks, their in-vivo monitoring remains rudimentary. In an effort to develop an intelligent artificial spinal disk where the in-vivo loading of the spine can by studied for the first time an experimental set up has been created in order to initially study the in-vitro loading on an artificial disc prosthesis. Eight strain gauges and two piezoresistive sensors were used and placed suitably in the artificial disk prosthesis. The results from the in-vitro loading showed linear relationship between loading and the outputs from the sensors with good repeatability and less hysteresis.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Wear assessments of a new cervical spinal disk prosthesis: Influence of loading and kinematic patterns during in vitro wear simulation
    Wu, Wenjie
    Lyu, Jingtong
    Liu, Hao
    Rong, Xin
    Wang, Beiyu
    Hong, Ying
    Gong, Quan
    Li, Tao
    Liu, Limin
    Song, Yueming
    Cai, Yong
    Xu, Wenli
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (09) : 619 - 628
  • [2] Development and in vitro evaluation of an artificial spinal disc loading cell
    Kyriacou, P. A.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4887 - 4890
  • [3] AN IN-VITRO INVESTIGATION OF THE RELATIONSHIP BETWEEN SPINAL NEEDLE DESIGN AND FAILED SPINAL ANESTHETICS
    SAYEED, YG
    SOSIS, MB
    BRAVERMAN, B
    IVANKOVICH, AD
    ANESTHESIOLOGY, 1993, 79 (3A) : A480 - A480
  • [4] In-vitro simulation of intraoral loading parameters
    Rosentritt, M
    Leibrock, A
    Lang, R
    Scharnagl, P
    Behr, M
    Handel, G
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1111 - 1111
  • [5] CROWN RETENTION AND CYCLIC LOADING (IN-VITRO)
    GUNDLER, A
    LOCKOWANDT, P
    ERHARDSON, S
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1993, 101 (04): : 252 - 256
  • [6] Artificial spinal disk superior to fusion for treating degenerative disk disease
    Zeller, John L.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (22): : 2665 - +
  • [7] Torque Stability of Plastic Brackets Following Multiple Loading and Artificial Material Aging - an In-Vitro Comparison
    Moeller, Matthias
    Klocke, Arndt
    Sadat-Khonsari, Reza
    Schlegel, Volker
    Kahl-Nieke, Baerbel
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2009, 70 (05): : 385 - 395
  • [8] In-vitro and in-vivo ceramic debris with ceramic prosthesis
    Toni, A.
    Traina, F.
    De Fine, M.
    Tassinari, E.
    Biondi, F.
    Galvani, A.
    Pilla, F.
    Stea, S.
    Bioceramics and Alternative Bearings in Joint Arthroplasty, 2007, : 45 - 47
  • [9] Experimental in-vitro method to measure the migration of cementless prosthesis
    Zivkovic, Ivan
    Amirouche, Farid
    Gonzalez, Mark H.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 681 - 682
  • [10] In Vitro Investigation of Friction under Edge Loading Conditions for Ceramic-on-Ceramic Total Hip Prosthesis
    Sariali, Elhadi
    Stewart, Todd
    Jin, Zhongming
    Fisher, John
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (08) : 979 - 985