Model for oxygen transfer in rotating biological contactor

被引:42
|
作者
Kubsad, V [1 ]
Chaudhari, S [1 ]
Gupta, SK [1 ]
机构
[1] Indian Inst Technol, Ctr Environm Sci & Engn, Bombay 400076, Maharashtra, India
关键词
oxygen transfer; RBC; volume renewal number; physical factors; scale-up;
D O I
10.1016/j.watres.2004.08.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Rotating biological contactor is being widely used for wastewater treatment but there is an apparent lack of knowledge about the rate at which oxygen transfer occurs, in physical and biological system. In this study the transfer of oxygen from air to water by a rotating disc air-liquid contactor in physical system is investigated. The oxygen transfer model suggested by Kim and Molof, Water Sci. Technol. 14 (1982) 569, was modified and the developed model is termed as modified Kim and Molof model. The model was calibrated by using available data in literature and validated by experiments conducted in this study. The effect of significant physical parameters was integrated into a single term and is termed as volume renewal number. The modified Kim and Molof model was compared with the other available models. The coefficient of determination (R-2) for the modified Kim and Molof model obtained is 0.95 which is much hi-her than in the other available models. Thereby the model is expected to estimate oxygen transfer more accurately. Further, a simplified linear model between K(L)a and the volume renewal number is proposed. Both modified Kim and Molof and linear model estimate the overall oxygen transfer coefficient (K(L)a) accurately. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4297 / 4304
页数:8
相关论文
共 50 条
  • [1] Dimensional analysis for modeling oxygen transfer in rotating biological contactor
    Chavan, Anal
    Mukherji, Suparna
    BIORESOURCE TECHNOLOGY, 2008, 99 (09) : 3721 - 3728
  • [2] Oxygen transfer characteristics and operational performance of rotating drum biological contactor
    Li, Ning
    Miao, Zhijia
    Li, Zaixing
    Wang, Zhongdong
    Qin, Xue
    Huang, Juan
    Huagong Xuebao/CIESC Journal, 2015, 66 (07): : 2678 - 2685
  • [3] DETERMINATION OF OXYGEN-TRANSFER RATE TO A ROTATING BIOLOGICAL CONTACTOR BY MICROELECTRODE MEASUREMENT
    NISHIDOME, K
    KUSUDA, T
    WATANABE, Y
    YAMAUCHI, M
    MIHARA, M
    WATER SCIENCE AND TECHNOLOGY, 1994, 29 (10-11) : 471 - 477
  • [4] MASS-TRANSFER IN A ROTATING BIOLOGICAL CONTACTOR
    SHIEH, WK
    WATER RESEARCH, 1982, 16 (06) : 1071 - 1074
  • [5] Oxygen mass transfer and post-denitrification in a modified rotating drum biological contactor
    Li, Ning
    Zeng, Wei
    Yang, Yanan
    Wang, Baogui
    Li, Zaixing
    Peng, Yongzhen
    BIOCHEMICAL ENGINEERING JOURNAL, 2019, 144 : 48 - 56
  • [6] HYDRODYNAMICS AND MASS-TRANSFER IN A ROTATING BIOLOGICAL CONTACTOR
    VAIDYA, RN
    PANGARKAR, VG
    CHEMICAL ENGINEERING COMMUNICATIONS, 1985, 39 (1-6) : 337 - 354
  • [7] A Residual Analysis for the Removal of Biological Oxygen Demand through Rotating Biological Contactor
    Daudpoto, Muhmammad Rafique
    Talpur, Mir Ghulam Haider
    Shah, Feroz
    Khooharo, Aijaz
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2021, 40 (02) : 459 - 464
  • [8] Mathematical modeling and simulation of oxygen mass transfer in rotating biological contactor (RBC) for bacterial cellulose production
    Hosseinzadeh, Abolhassan
    Chegeni, Asma
    Babaeipour, Valiollah
    BIOCHEMICAL ENGINEERING JOURNAL, 2023, 200
  • [9] A ROTATING BIOLOGICAL EXTENDED CONTACTOR
    KRZEMIENIEWSKI, M
    BIOLOGICAL WASTES, 1989, 29 (04): : 271 - 277
  • [10] NEW ROTATING BIOLOGICAL CONTACTOR
    不详
    EFFLUENT & WATER TREATMENT JOURNAL, 1978, 18 (10): : 537 - 537