Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation

被引:88
|
作者
Yoshida, K [1 ]
Horch, K [1 ]
机构
[1] UNIV UTAH,DEPT BIOENGN,SALT LAKE CITY,UT 84112
基金
美国国家卫生研究院;
关键词
D O I
10.1109/10.481986
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a closed-loop functional neuromuscular stimulation system that uses afferent neural activity from muscle spindle fibers as feedback for controlling position of the ankle joint, Ankle extension against a load was effected by neural stimulation through a dual channel intrafascicular electrode of a fascicle of the tibial nerve that innervated the gastrocnemius muscle, Ankle joint angle was estimated from recordings of tibialis anterior and lateral gastrocnemius spindle fiber activity made with dual channel intrafascicular electrodes. Experiments were conducted in neurally intact anesthetized cats and in unanesthetized decerebrate cats to demonstrate the feasibility of this system, The system was able to reach and maintain a fixed target ankle position in the presence of a varying external moment ranging in magnitude between 7.3 and 22 N-cm opposing the action of the ankle extensor, as well as track a sinusoidal target ankle position up to a frequency of 1 Hz in the presence of a constant magnitude 22- or 37-N-cm external moment.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 50 条
  • [1] A NATURAL FORCE SENSOR SUITABLE FOR CLOSED-LOOP CONTROL OF FUNCTIONAL NEUROMUSCULAR STIMULATION
    HOFFER, JA
    SINKJAER, T
    ARTIFICIAL ORGANS, 1987, 11 (05) : 426 - 426
  • [2] Ankle-Angle Estimation from Blind Source Separated Afferent Activity in the Sciatic Nerve for Closed-Loop Functional Neuromuscular Stimulation System
    Song, Kang-Il
    Chu, Jun-Uk
    Park, Sunghee E.
    Hwang, Dosik
    Youn, Inchan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) : 834 - 843
  • [3] Flexible Peripheral Nerve Interfacing Electrode for Joint Position Control in Closed-Loop Neuromuscular Stimulation
    Kim, Sia
    Song, Kang-Il
    MICROMACHINES, 2024, 15 (05)
  • [4] The impact of the stimulation frequency on closed-loop control with electrotactile feedback
    Paredes, Liliana P.
    Dosen, Strahinja
    Rattay, Frank
    Graimann, Bernhard
    Farina, Dario
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
  • [5] The impact of the stimulation frequency on closed-loop control with electrotactile feedback
    Liliana P Paredes
    Strahinja Dosen
    Frank Rattay
    Bernhard Graimann
    Dario Farina
    Journal of NeuroEngineering and Rehabilitation, 12
  • [6] A technique for sequential segmental neuromuscular stimulation with closed loop feedback control
    Zonnevijlle, EDH
    Abadia, GP
    Somia, NN
    Kon, M
    Barker, JH
    Koenig, S
    Ewert, DL
    Stremel, RW
    JOURNAL OF INVESTIGATIVE SURGERY, 2002, 15 (02) : 91 - 99
  • [7] Closed-loop neuromuscular electrical stimulation using feedforward-feedback control and textile electrodes to regulate grasp force in quadriplegia
    Ciancibello J.
    King K.
    Meghrazi M.A.
    Padmanaban S.
    Levy T.
    Ramdeo R.
    Straka M.
    Bouton C.
    Bioelectronic Medicine, 2019, 5 (01)
  • [8] CLOSED-LOOP MANIPULATOR CONTROL USING QUATERNION FEEDBACK
    YUAN, JSC
    IEEE JOURNAL OF ROBOTICS AND AUTOMATION, 1988, 4 (04): : 434 - 440
  • [9] Closed-loop position control system using LAVIEW
    Aaron, KR
    Foster, NL
    Hazel, DP
    Basher, AMH
    IEEE SOUTHEASTCON 2002: PROCEEDINGS, 2002, : 283 - 286
  • [10] Closed-loop functional optogenetic stimulation
    Shriya S. Srinivasan
    Benjamin E. Maimon
    Maurizio Diaz
    Hyungeun Song
    Hugh M. Herr
    Nature Communications, 9