Adaptive comfort temperature model of air-conditioned building in Hong Kong

被引:142
|
作者
Mui, KWH [1 ]
Chan, WTD [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hung Hom HKSAR, Kowloon, Hong Kong, Peoples R China
关键词
adaptive comfort temperature; thermal comfort; indoor air temperature setpoint;
D O I
10.1016/S0360-1323(03)00020-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor thermal climate is an important issue affecting the health and productivity of users in buildings. In designing of air-conditioning systems, it is believed that the conventional fixed temperature setpoint concept is not appropriates, the indoor comfort temperature depends on the outdoor air temperature and the business culture, such as the nature of activities, dress of occupants, etc. Researchers have been interested in investigating adaptive temperature control for a realistic in situ temperature control for comfort. Unfortunately, these studies put great emphasis on the energy saving opportunity, rather than providing an integrated solution. In this paper, we report the findings of a large-scale survey that was performed to develop new notions about adaptive comfort temperature (ACT) in buildings in humid sub-tropical Hong Kong, and determine the adaptive interface relationship of indoor comfort temperature with outdoor air temperature in order to preset the indoor air temperature as a function of outdoor air temperature. This ACT algorithm is intended to optimise the energy used for cooling that air, but achieve the acceptance of thermal comfort, as determined by physical measurements and subjective surveys. With the integration of the ACT model, the total percentage of energy saving is about 7%. (C) 2003 Published by Elsevier Science Ltd.
引用
收藏
页码:837 / 852
页数:16
相关论文
共 50 条
  • [1] Comfort Zone of Air Speeds and Temperatures for Air-conditioned Environment in the Subtropical Hong Kong
    Fong, K. F.
    Chow, T. T.
    Li, C.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2010, 19 (03) : 375 - 381
  • [2] Building energy performance of air-conditioned office buildings in Hong Kong
    Chan, RYC
    Lam, JC
    Li, DHW
    Tsang, EKW
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 985 - 992
  • [3] Adaptive thermal comfort model for air-conditioned hospitals in Malaysia
    Yau, Y. H.
    Chew, B. T.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (02): : 117 - 138
  • [4] Formaldehyde exposure risk in air-conditioned offices of Hong Kong
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    Chan, W. Y.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2009, 30 (04): : 279 - 286
  • [5] Thermal sensation of Hong Kong people with increased air speed, temperature and humidity in air-conditioned environment
    Chow, T. T.
    Fong, K. F.
    Givoni, B.
    Lin, Zhang
    Chan, A. L. S.
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2177 - 2183
  • [6] Ventilation of air-conditioned residential buildings: A case study in Hong Kong
    Z.T.Ai
    C.M.Mak
    D.J.Cui
    P.Xue
    侯恩哲
    [J]. 建筑节能(中英文), 2016, 44 (09) : 5 - 5
  • [7] Ventilation of air-conditioned residential buildings: A case study in Hong Kong
    Ai, Z. T.
    Mak, C. M.
    Cui, D. J.
    Xue, P.
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 116 - 127
  • [8] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Pui-Shan Hui
    Kwok-Wai Mui
    Ling-Tim Wong
    [J]. Environmental Monitoring and Assessment, 2008, 144 : 315 - 322
  • [9] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Hui, Pui-Shan
    Mui, Kwok-Wai
    Wong, Ling-Tim
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 144 (1-3) : 315 - 322
  • [10] An approach to assessing the probability of unsatisfactory radon in air-conditioned offices of Hong Kong
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2008, 99 (02) : 248 - 259