Monte Carlo-based multiphysics coupling analysis of X-ray pulsar telescope

被引:1
|
作者
Li, Liansheng [1 ]
Deng, Loulou [1 ]
Mei, Zhiwu [1 ]
Zuo, Fuchang [1 ]
Zhou, Hao [1 ]
机构
[1] Beijing Inst Control Engn, Beijing, Peoples R China
关键词
Monte Carlo; X-ray pulsar telescope; multi-physics coupling analysis; finite element method; focusing performance;
D O I
10.1117/12.2194878
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray pulsar telescope (XPT) is a complex optical payload, which involves optical, mechanical, electrical and thermal disciplines. The multiphysics coupling analysis (MCA) plays an important role in improving the in-orbit performance. However, the conventional MCA methods encounter two serious problems in dealing with the XTP. One is that both the energy and reflectivity information of X-ray can't be taken into consideration, which always misunderstands the essence of XPT. Another is that the coupling data can't be transferred automatically among different disciplines, leading to computational inefficiency and high design cost. Therefore, a new MCA method for XPT is proposed based on the Monte Carlo method and total reflective theory. The main idea, procedures and operational steps of the proposed method are addressed in detail. Firstly, it takes both the energy and reflectivity information of X-ray into consideration simultaneously. And formulate the thermal-structural coupling equation and multiphysics coupling analysis model based on the finite element method. Then, the thermal-structural coupling analysis under different working conditions has been implemented. Secondly, the mirror deformations are obtained using construction geometry function. Meanwhile, the polynomial function is adopted to fit the deformed mirror and meanwhile evaluate the fitting error. Thirdly, the focusing performance analysis of XPT can be evaluated by the RMS. Finally, a Wolter-I XPT is taken as an example to verify the proposed MCA method. The simulation results show that the thermal-structural coupling deformation is bigger than others, the vary law of deformation effect on the focusing performance has been obtained. The focusing performances of thermal-structural, thermal, structural deformations have degraded 30.01%, 14.35% and 7.85% respectively. The RMS of dispersion spot are 2.9143mm, 2.2038mm and 2.1311mm As a result, the validity of the proposed method is verified through comparing the simulation results and experiments, which can be employed in the reliability-based design of XPT.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A Simulation Method for X-ray Pulsar Signal Based on Monte Carlo
    Jin, Jing
    Liu, Yixiao
    Li, Xiaoyu
    Shen, Yi
    Huang, Liangwei
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 1937 - 1942
  • [2] Monte Carlo polarimetric simulations of a hard X-ray energy telescope
    da Silva, RMC
    Caroli, E
    Stephen, JB
    Siffert, P
    [J]. X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 : 70 - 78
  • [3] Monte Carlo simulations of the design of a hard X-ray telescope optimised for polarimetry
    da Silva, RMC
    Caroli, E
    Stephen, JB
    Siffert, P
    [J]. POLARIMETRY IN ASTRONOMY, 2003, 4843 : 543 - 553
  • [4] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [5] Monte Carlo-based sensitivity analysis of an electrochemical capacitor
    Kannan, Vishvak
    Somasundaram, Karthik
    Fisher, Adrian
    Birgersson, Erik
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (11) : 16947 - 16962
  • [6] Monte Carlo-based analysis of PET scatter components
    Adam, LE
    Bellemann, ME
    Brix, G
    Lorenz, WJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (12): : 2024 - 2029
  • [7] A Fast Monte Carlo-Based Dose Calculation Platform for Pre-Clinical Radiobiology Experiments Using An X-Ray Irradiator
    Liu, H.
    Zhong, Y.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E680 - E680
  • [8] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305
  • [9] Monte Carlo simulation for x-ray detector
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Niu, Lihong
    Peng, Wenda
    Long, Jinghua
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [10] A Monte Carlo simulation of x-ray mammography
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 842 - 843