Markedly Different Tissue Types on Optical Coherence Tomography Imaging in a Patient With Multiple Lesion Drug-Eluting Stent In-Stent Restenosis

被引:3
|
作者
Rheude, Tobias A. [1 ]
Xhepa, Erion [1 ]
Byrne, Robert A. [1 ]
机构
[1] Tech Univ Munich, Klin Herz & Kreislauferkrankungen, Deutsch Herzzentrum Munchen, Munich, Germany
关键词
drug coated/eluting balloon; optical coherence tomography; restenosis; NEOATHEROSCLEROSIS;
D O I
10.1002/ccd.26694
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The treatment of in-stent restenosis after drug-eluting stent (DES) implantation remains a major clinical challenge. Optical coherence tomography (OCT) imaging at the time of presentation can provide important information on mechanical factors contributing to stent failure as well as on tissue characteristics of the in-stent neointimal tissue. We report a case of markedly different tissue types-characterized by heterogeneous and homogeneous signal intensity-observed in a patient with multiple lesion DES in-stent restenosis. Although both lesions were initially successfully treated with drug-coated balloon angioplasty, the patient presented with recurrent in-stent restenosis in the lesion with homogeneous tissue characteristics. Future studies should evaluate whether OCT tissue characterization can guide optimal treatment strategy in patients with DES restenosis. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:E181 / E184
页数:4
相关论文
共 50 条
  • [1] Difference of In-Stent Restenosis Pattern of Drug-Eluting Stent in Early and Late Phase Restenosis: Optical Coherence Tomography Analysis
    Domei, Takenori
    Kuramitsu, Shoichi
    Hyodo, Makoto
    Soga, Yoshimitsu
    Arita, Takeshi
    Shirai, Shinichi
    Ando, Kenji
    Kondo, Katsuhiro
    Sakai, Koyu
    Yokoi, Hiroyoshi
    Iwabuchi, Masashi
    Nobuyoshi, Masakiyo
    CIRCULATION, 2011, 124 (21)
  • [2] Optical coherence tomography patterns of in-stent restenosis: comparison between drug-eluting stent and bare-metal stent
    Watanabe, Y.
    Asano, R.
    Takamisawa, I.
    Seki, A.
    Tobaru, T.
    Takayama, M.
    Umemura, J.
    Sumiyoshi, T.
    EUROPEAN HEART JOURNAL, 2010, 31 : 300 - 300
  • [3] In-Stent Restenosis in the Drug-Eluting Stent Era
    Dangas, George D.
    Claessen, Bimmer E.
    Caixeta, Adriano
    Sanidas, Elias A.
    Mintz, Gary S.
    Mehran, Roxana
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (23) : 1897 - 1907
  • [4] In Vivo Optical Coherence Tomography of Very Late Drug-Eluting Stent Thrombosis Compared With Late In-Stent Restenosis
    Miyazaki, Shinichiro
    Hiasa, Yoshikazu
    Takahashi, Takefumi
    Yano, Yudai
    Minami, Tomoko
    Murakami, Naotsugu
    Mizobe, Michiko
    Tobetto, Yohei
    Nakagawa, Takafumi
    Chen, Po-Min
    Ogura, Riyo
    Miyajima, Hitoshi
    Yuba, Kenichiro
    Hosokawa, Shinobu
    Kishi, Koichi
    Ohtani, Ryuji
    CIRCULATION JOURNAL, 2012, 76 (02) : 390 - 398
  • [5] Effect of different drug-eluting stent design on in-stent restenosis and stent thrombosis
    Angeras, Oskar
    Albertsson, Per
    Dworeck, Christian
    Haraldsson, Inger
    Ioanes, Dan
    Libungan, Berglind
    Matejka, Goran
    Omerovic, Elmir
    Petursson, Petur
    Ramunddal, Truls
    Ridderstrale, Wilhelm
    Robertsson, Lotta
    Stewart, Jason
    Wahlin, Magnus
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B146 - B146
  • [6] Difference of Tissue Characteristics of Restenosis Lesion Between Drug-Eluting Stent and Bare-Metal Stent: Optical Coherence Tomography Analysis
    Habara, Maoto
    Terashima, Mitsuyasu
    Nasu, Kenay
    Ko, Yoshihiro
    Ito, Tsuyoshi
    Ebisawa, Soichiro
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Ehara, Mariko
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Yasushi
    Kato, Osamu
    Suzuki, Takahiko
    CIRCULATION, 2010, 122 (21)
  • [7] Optical coherence tomography characterization of in-stent restenosis: comparison between generations of drug eluting stent
    Dall'ara, G.
    Kilickesmez, K. O.
    Rama-Merchan, J. C.
    Ghione, M.
    Mattesini, A.
    Konstantinidis, N.
    Pighi, M.
    Estevez-Loureiro, R.
    Secco, G. G.
    Di Mario, C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 27 - 27
  • [8] The morphological findings of early and late in-stent restenosis after drug-eluting stent implantation: optical coherence tomography analysis
    Yamaguchi, H.
    Takaoka, J.
    Miyamura, A.
    Atsuchi, N.
    Shirasawa, H.
    Arikawa, R.
    Atsuchi, Y.
    EUROPEAN HEART JOURNAL, 2011, 32 : 747 - 747
  • [9] Comparison of drug-eluting balloon with repeat drug-eluting stent for recurrent drug-eluting stent in-stent restenosis
    Wang, Guozhong
    Zhao, Quanming
    Chen, Qing
    Zhang, Xiaoxia
    Tian, Lei
    Zhang, Xiaojiang
    CORONARY ARTERY DISEASE, 2019, 30 (07) : 473 - 480
  • [10] The morphological findings of early and late in-stent restenosis after drug-eluting stent implantation: optical coherence tomography analysis
    Yamaguchi, H.
    Takaoka, J.
    Miyamura, A.
    Atsuchi, N.
    Shirasawa, H.
    Arikawa, R.
    Atsuchi, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 : 747 - 747