Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic Dissection

被引:74
|
作者
Sze, Daniel Y. [1 ]
van den Bosch, Maurice A. A. J. [1 ]
Dake, Michael D. [1 ,2 ]
Miller, D. Craig [2 ]
Hofmann, Lawrence V. [1 ]
Varghese, Robin [2 ]
Malaisrie, S. Chris [2 ]
van der Starre, Pieter J. A. [3 ]
Rosenberg, Jarrett [4 ]
Mitchell, R. Scott [2 ]
机构
[1] Stanford Univ, Med Ctr, Div Intervent Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[3] Stanford Univ, Med Ctr, Dept Anesthesia, Stanford, CA 94305 USA
[4] Stanford Univ, Med Ctr, Dept Biostat, Stanford, CA 94305 USA
关键词
aorta; dissection; surgery; complications; LEFT SUBCLAVIAN ARTERY; ENDOVASCULAR REPAIR; B DISSECTION; PLACEMENT; ANEURYSMS; EXPERIENCE; MANAGEMENT; COVERAGE; STILL;
D O I
10.1161/CIRCINTERVENTIONS.108.819722
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Endoleaks after stent-graft repair of aortic dissections are poorly understood but seem substantially different from those seen after aneurysm repair. We studied anatomic and clinical factors associated with endoleaks in patients who underwent stent-graft repair of complicated type B aortic dissections. Methods and Results-From 2000 to 2007, 37 patients underwent stent-graft repair of acute (<= 14 days; n=23), subacute (15 to 90 days; n=10) or chronic (>90 days; n=4) complicated type B aortic dissections using the Gore Thoracic Excluder (n=17) or TAG stent-grafts (n=20) under an investigator-sponsored protocol. Endoleaks were classified as imperfect proximal seal, flow through fenestrations or branches, or complex (both). Variables studied included coverage of the left subclavian artery, aortic curvature, completeness of proximal apposition, dissection chronicity, and device used. Endoleaks were found during follow-up (mean, 22 months) in 59% of patients, and they were associated with coverage of the left subclavian artery (complex, P<0.001), small radius of curvature (type 1 and complex, P<0.05), and greatest length of unapposed proximal stent graft (complex, P<0.0001). During follow-up, 10 endoleaks resolved spontaneously, 6 required reintervention for false lumen dilatation, and 2 were stable without clinical consequences. Conclusions-Endoleaks are common after stent-graft repair of aortic dissection and may lead to false lumen enlargement necessitating reintervention. Anatomic complexities such as acute aortic curvature and covered side branches were associated with endoleaks, illustrating the need for dissection-specific device development. (Circ Cardiovasc Intervent. 2009; 2: 105-112.)
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [1] Stent-graft detachment from aortic wall after stent-graft repair of acute aortic dissection
    Kato, N
    Shimono, T
    Hirano, T
    Ishida, M
    Takeda, K
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 38 (05) : 1130 - 1131
  • [2] THORACIC AORTIC STENT-GRAFT INFECTION COMPLICATED BY AORTIC ABSCESS
    Conte, Gabriella
    Shariff, Mohammed
    Khan, Taimoor
    Ajam, Firas
    Mikhail, John
    [J]. CHEST, 2019, 156 (04) : 1521A - 1521A
  • [3] Type A dissection following endovascular thoracic aortic stent-graft repair
    Neuhauser, B
    Czermak, BV
    Fish, J
    Perkmann, R
    Jaschke, W
    Chemelli, A
    Fraedrich, G
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 74 - 81
  • [4] Factors favoring stent-graft collapse after thoracic endovascular aortic repair
    Canaud, Ludovic
    Alric, Pierre
    Desgranges, Pascal
    Marzelle, Jean
    Marty-Ane, Charles
    Becquemin, Jean-Pierre
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05): : 1153 - 1157
  • [5] Type III endoleak from a thoracic aortic stent-graft
    Lange, C
    Odegård, A
    Lundbom, J
    Hatlinghus, S
    Myhre, HO
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (04) : 535 - 538
  • [6] Stent-Graft Repair of Thoracic Aortic Aneurysms
    Rousseau, H.
    Bolduc, J. P.
    Dambrin, C.
    Marcheix, B.
    Canevet, G.
    Otal, P.
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 8 (01) : 61 - 72
  • [7] Endoluminal stent-graft stabilization for thoracic aortic dissection
    Nathanson, DR
    Rodriguez-Lopez, JA
    Ramaiah, VG
    Williams, J
    Olsen, DM
    Wheatley, GH
    Diethrich, EB
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (03) : 354 - 359
  • [8] Thoracic endovascular stent-graft therapy in aortic dissection
    Akin, Ibrahim
    Kische, Stephan
    Rehders, Tim C.
    Ince, Hueseyin
    Nienaber, Christoph A.
    [J]. CURRENT OPINION IN CARDIOLOGY, 2010, 25 (06) : 552 - 559
  • [9] Descending thoracic aortic diseases: Stent-graft repair
    Fattori, R
    Napoli, G
    Lovato, L
    Grazia, C
    Piva, T
    Rocchi, G
    Angeli, E
    Di Bartolomeo, R
    Gavelli, G
    [J]. RADIOLOGY, 2003, 229 (01) : 176 - 183
  • [10] Endovascular stent-graft repair of thoracic aortic aneurysms
    Mitchell, RS
    Dake, MD
    Semba, CP
    Fogarty, TJ
    Zarins, CK
    Liddell, RP
    Miller, DC
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05): : 1054 - 1060