High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry

被引:58
|
作者
Staerk, U [1 ]
Külpmann, WR [1 ]
机构
[1] Med Univ, D-30625 Hannover, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 745卷 / 02期
关键词
solid-phase microextraction; drugs;
D O I
10.1016/S0378-4347(00)00312-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove Lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 mu g/l), barbiturates (500 mu g/l), benzodiazepines (100 mu g/l), benzoylecgonine (150 mu g/l), methadone (100 mu g/l) and opiates (200 mu g/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:399 / 411
页数:13
相关论文
共 50 条
  • [1] Optimisation of a solid-phase microextraction procedure for the determination of triazines in water with gas chromatography-mass spectrometry detection
    Frías, S
    Rodríguez, MA
    Conde, JE
    Pérez-Trujillo, JP
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1007 (1-2) : 127 - 135
  • [2] Rapid screening procedure based on headspace solid-phase microextraction and gas chromatography-mass spectrometry for the detection of many recreational drugs in hair
    Gentili, S
    Cornetta, M
    Macchia, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02): : 289 - 296
  • [3] Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry
    Vílchez, JL
    Prieto, A
    Araujo, L
    Navalón, A
    JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) : 215 - 221
  • [4] Simultaneous detection of amphetamine-like drugs with headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Gentili, S
    Torresi, A
    Marsili, R
    Chiarotti, M
    Macchia, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (01): : 183 - 192
  • [5] Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry
    Navalón, A
    Prieto, A
    Araujo, L
    Vílchez, JL
    CHROMATOGRAPHIA, 2001, 54 (5-6) : 377 - 382
  • [6] Characterisation of whiskeys using solid-phase microextraction with gas chromatography-mass spectrometry
    Fitzgerald, G
    James, KJ
    MacNamara, K
    Stack, MA
    JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) : 351 - 359
  • [7] Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry
    A. Navalón
    A. Prieto
    L. Araujo
    J. L. Vílchez
    Chromatographia, 2001, 54 : 377 - 382
  • [8] Characterization of rum using solid-phase microextraction with gas chromatography-mass spectrometry
    Pino, Jorge A.
    FOOD CHEMISTRY, 2007, 104 (01) : 421 - 428
  • [9] Analysis of aroma components in kiwifruit by gas chromatography-mass spectrometry with solid-phase microextraction
    Zheng, XH
    Weng, XX
    Deng, CH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (06) : 834 - 834
  • [10] Application of solid-phase microextraction and gas chromatography-mass spectrometry for the determination of chlorophenols in leather
    de Souza Silveira, Cristine D.
    Martendal, Edmar
    Soldi, Valdir
    Carasek, Eduardo
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (04) : 602 - 607