The inter- and intra-rater reliability of Modified Tardieu Scale in assessing spasticity of knee extensors in patients with multiple sclerosis

被引:2
|
作者
Azarnia, Somayeh [1 ]
Abdollahi, Iraj [2 ]
Minoo, Maryam [1 ]
Naghdi, Soofia [3 ]
Salavati, Mahyar [2 ]
机构
[1] Guilan Univ Med Sci, Sch Med, Rasht, Iran
[2] Univ Welf & Rehabil, Sch Rehabil, Dept Phys Therapy, Physiotherapy, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Rehabil, Dept Physiotherapy, Tehran, Iran
关键词
Spasticity; Multiple sclerosis; Modified tardieu scale; Inter-rater reliability; Intra-rater reliability; MODIFIED ASHWORTH SCALE; ADULT PATIENTS; CHILDREN; LIMB;
D O I
10.1016/j.jbmt.2020.09.004
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Introduction: Spasticity is one of the most common and disabling symptoms in Multiple sclerosis (MS). The is a clinical tool for assessing spasticity. This study aimed to investigate the inter- and intra-rater reliability of the modified Tardieu scale for assessing knee extensors spasticity in MS patients. Methods: Twenty-six patients with MS (12 females and 14 males) with a mean age of 40 +/- 11.39 years participated in this study. The extensor muscles of both knees were evaluated using the MTS in two sessions. At first session, two examiners randomly assessed the knee extensor spasticity to study the inter-rater reliability and 3-4 days later the first examiner assessed the patients again, to determine intra-rater reliability. Intra-class Correlation Coefficient (ICC) analysis, two-way random effect model was used to determine the reliability of various components of the modified Tardieu scale. Results: The inter-rater reliability for quality of muscle reaction of knee extensor muscles was very good (ICC = 0.89) and for the difference between the angle of muscle response (R1) and full range(R2) of movement (R2-R1), as spasticity intensity criterion, was good (ICC = 0.73). ICC values for R2-R1 and muscle response quality assessments by one rater were 0.73 and 0.82, respectively. Conclusion: The findings of the current study showed that the MTS has good to very good inter- and intra-rater reliability for assessing knee extensors spasticity in MS patients. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [1] Intra-rater reliability of the Modified Tardieu Scale in patients with multiple sclerosis
    Naghdi, Soofia
    Ansari, Noureddin Nakhostin
    Ghorbani-rad, Sedighe
    Senobari, Maryam
    Sahraian, Mohammad Ali
    [J]. NEUROLOGICAL SCIENCES, 2017, 38 (01) : 93 - 99
  • [2] Intra-rater reliability of the Modified Tardieu Scale in patients with multiple sclerosis
    Soofia Naghdi
    Noureddin Nakhostin Ansari
    Sedighe Ghorbani-rad
    Maryam Senobari
    Mohammad Ali Sahraian
    [J]. Neurological Sciences, 2017, 38 : 93 - 99
  • [3] Clinical assessment of ankle plantarflexor spasticity in adult patients after stroke: Inter-and intra-rater reliability of the Modified Tardieu Scale
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Rastgoo, Maryam
    Amini, Malek
    Forogh, Bijan
    [J]. BRAIN INJURY, 2013, 27 (05) : 605 - 612
  • [4] Inter- and intra-rater reliability of the modified modified ashworth scale in the assessment of muscle spasticity in cerebral palsy: A preliminary study
    Ansari, Noureddin Nakhostin
    Rahimi, Maryam
    Naghdi, Soofia
    Barzegar-Ganji, Zahra
    Hasson, Scott
    Moghimi, Ehsan
    [J]. JOURNAL OF PEDIATRIC REHABILITATION MEDICINE, 2022, 15 (01) : 151 - 158
  • [5] Inter- and Intra-rater Reliability of the Head Control Scale: Brief Report
    Dumas, Helene M.
    Rosen, Elaine L.
    Viray, Damara
    Sutherland, Colleen
    Seifert, Morgan
    Ni, Pengsheng
    [J]. DEVELOPMENTAL NEUROREHABILITATION, 2022, 25 (01) : 68 - 71
  • [6] INTER- AND INTRA-RATER VARIABILITY OF TESTING VELOCITY WHEN ASSESSING LOWER LIMB SPASTICITY
    Banky, Megan
    Clark, Ross A.
    Pua, Yong-Hao
    Mentiplay, Benjamin F.
    Olver, John H.
    Williams, Gavin
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2019, 51 (01) : 54 - 60
  • [7] Inter- and intra-rater reliability of the Modified Ashworth Scale: a systematic review and meta-analysis
    Meseguer-Henarejos, Ana-Belen
    Sanchez-Meca, Julio
    Lopez-Pina, Jose-Antonio
    Carles-Hernandez, Ricardo
    [J]. EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2018, 54 (04) : 576 - 590
  • [8] INTER- AND INTRA-RATER RELIABILITY IN THE DIAGNOSIS AND STAGING OF ENDOMETRIOSIS
    Schliep, K.
    Stanford, J.
    Chen, Z.
    Zhang, B.
    Dorais, J.
    Johnstone, E.
    Hammoud, A.
    Varner, M.
    Louis, G. Buck
    Peterson, M.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2012, 175 : S137 - S137
  • [9] Finger circumference measurements: inter- and intra-rater reliability
    Lewis, Erika S.
    [J]. HAND THERAPY, 2010, 15 (03) : 69 - 72
  • [10] Intra-rater reliability of the modified Tardieu scale to quantify spasticity in elbow flexors and ankle plantar flexors in adult stroke subjects
    Singh, Priyanka
    Joshua, Abraham M.
    Ganeshan, Sailakshmi
    Suresh, Sucharitha
    [J]. ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2011, 14 (01) : 23 - 26