Non-invasive measurement of arterial longitudinal movement

被引:0
|
作者
Persson, M [1 ]
Ahlgren, AR [1 ]
Eriksson, A [1 ]
Jansson, T [1 ]
Persson, HW [1 ]
Lindström, K [1 ]
机构
[1] Lund Univ, Dept Elect Measurements, S-22100 Lund, Sweden
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In arterial vessel wall characterisation the longitudinal movements of vessels have gained little or no attention. It has been presumed that the arterial vessels move very little in the longitudinal direction. With modem high resolution ultrasound it can, however, be seen that arterial vessels move not only in the circumferential, but also in longitudinal direction. This paper describes a non-invasive, ultrasound based method which estimates the longitudinal and the circumferential movement, respectively. The method is demonstrated in a limited in vivo study of the common carotid artery. Results show that, apart from the well known circumferential movement, there is a distinct longitudinal movement.
引用
收藏
页码:1783 / 1786
页数:4
相关论文
共 50 条
  • [1] Non-invasive measurements of longitudinal strain of the arterial wall
    Cinthio, Magnus
    Jansson, Tomas
    Persson, Hans W.
    Lindstrom, Kjell
    Ahlgren, Asa Ryden
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 570 - 572
  • [2] Non-Invasive Measurement of Arterial pH During Cardiopulmonary Bypass
    Al-Ghali, Basma A.
    Alzubeidy, Hussein H.
    Al-Dahan, Ziad T.
    [J]. INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2022, 18 (10) : 190 - 198
  • [3] TOWARDS ACCURATE NON-INVASIVE MEASUREMENT OF ARTERIAL-PRESSURE
    FINNIE, KJC
    ARMSTRONG, PW
    [J]. CLINICAL RESEARCH, 1980, 28 (02): : A168 - A168
  • [4] A Flexible Inductive Sensor for Non-Invasive Arterial Pulse Measurement
    Kumar, Nimal Jagadeesh
    Johnson, Alexander
    Cobden, Robert
    Valsamakis, George
    Gristock, J. Gene
    Pouryazdan, Arash
    Roggen, Daniel
    Munzenrieder, Niko
    [J]. 2023 IEEE SENSORS, 2023,
  • [5] Non-invasive measurement of arterial pressure-dependent compliance
    Liu, Changchun
    Xin, Sun
    Liu, Chengyu
    Gu, Jason J.
    Yu, Mengsun
    [J]. 2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 590 - 593
  • [6] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [7] Arterial compliance measurement using a non-invasive laser Doppler measurement system
    Hast, J
    Myllylä, R
    Sorvoja, H
    Nissilä, S
    [J]. OPTICAL TECHNIQUES AND INSTRUMENTATION FOR THE MEASUREMENT OF BLOOD COMPOSITION, STRUCTURE AND DYNAMICS, 2000, 4163 : 24 - 32
  • [8] CURRENT DEVELOPMENTS IN NON-INVASIVE MEASUREMENT OF ARTERIAL BLOOD-PRESSURE
    YAMAKOSHI, K
    ROLFE, P
    MURPHY, C
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02): : 130 - 137
  • [9] Non-invasive measurement of arterial pulse waves of a GMI pressure transducer
    Louzada, D. Ramos
    Monteiro, E. Costa
    Gusmao, L. A. P.
    Barbosa, C. Hall
    [J]. IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 436 - +
  • [10] A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement
    Rebesco, Matthew R.
    Pinkston, M. Cornelia
    Smyrnios, Nicholas A.
    Weisberg, Stacy N.