Determination of distribution constants between a liquid polymeric coating and water by a solid phase microextraction technique with a flow-through standard water system

被引:49
|
作者
Shurmer, B [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac991395b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes an optimized experimental system for determining water/polymer coating distribution constants and discusses the mechanism of extraction of high molecular weight compounds by poly(dimethylsiloxane) (PDMS). The proposed flow-through standard water generator eliminates errors associated with both losses of analytes to the system surfaces and limited sample volume. In addition, the errors caused by partial precipitation or poor dissolution of highly hydrophobic analytes during spiking of water when producing calibration standards are also eliminated. The target analytes are a range of polycyclic aromatic hydrocarbons (PAHs). The results demonstrate that absorption partitioning is the predominant mechanism of extraction of analytes into PDMS-coated fibers for all PAHs investigated regardless of molecular weight. There is a strong correlation between determined PDMS/water distribution constants (K-fw) and literature K-ow values for all PAHs.
引用
收藏
页码:3660 / 3664
页数:5
相关论文
共 50 条
  • [1] DETERMINATION OF COBALT IN WATER USING A FLOW-THROUGH SENSOR SYSTEM
    TRUTNEVA, LM
    SHVOEVA, OP
    SAVVIN, SB
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (05) : 426 - 429
  • [2] Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings
    Lopez-Darias, Jessica
    Pino, Veronica
    Anderson, Jared L.
    Graham, Christa M.
    Afonso, Ana M.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1236 - 1243
  • [3] Indirect electrochemical determination of sulfates in mineral water by a flow-through system
    Cacho, Frantisek
    Masac, Jakub
    Zakhar, Ronald
    Beinrohr, Ernest
    TALANTA, 2020, 207
  • [4] A new procedure for solid-phase microextraction using a flow-through system with air segmentation
    Souza, ÉS
    Carasek, E
    ANALYST, 2002, 127 (05) : 603 - 607
  • [5] Determination of Polycyclic Aromatic Hydrocarbons in Water by Solid-Phase Microextraction and Liquid Chromatography
    Hong-Wen Chen
    Analytical Sciences, 2004, 20 : 1383 - 1388
  • [6] Determination of polycyclic aromatic hydrocarbons in water by solid-phase microextraction and liquid chromatography
    Chen, HW
    ANALYTICAL SCIENCES, 2004, 20 (10) : 1383 - 1388
  • [7] Ordered Mesoporous Carbon as Solid-phase Microextraction Coating for Determination of Some Chlorobenzenes in Water
    Jiang Ming-Yue
    Li Jian-Sheng
    Jiang Hui
    Qi Jun-Wen
    Liu Chao
    Wang Lian-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 1 - 7
  • [8] Determination of plastic monomers in water by solid-phase microextraction coupled with liquid chromatography
    Batlle, R
    Sánchez, C
    Nerín, C
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (02) : 431 - 436
  • [9] An etched stainless steel wire/ionic liquid-solid phase microextraction technique for the determination of alkylphenols in river water
    Cui, Meiyu
    Qiu, Jinxue
    Li, Zhenghua
    He, Miao
    Jin, Mingshi
    Kim, Jiman
    Quinto, Maurizio
    Li, Donghao
    TALANTA, 2015, 132 : 564 - 571
  • [10] Determination of ascorbic acid by use of a flow-through solid phase UV spectrophotometric system
    A. Molina-Díaz
    A. Ruiz-Medina
    M. L. Fernández-de Córdova
    Fresenius' Journal of Analytical Chemistry, 1999, 363 : 92 - 97