Reproducibility of ambulatory blood pressure monitoring in hemodialysis patients

被引:77
|
作者
Peixoto, AJ
Santos, SFF
Mendes, RB
Crowley, ST
Maldonado, R
Orias, M
Mansoor, GA
White, WB
机构
[1] W Haven VA Med Ctr, Renal Sect 111F, W Haven, CT 06510 USA
[2] Yale Univ, Sch Med, Gen Internal Med Sect, W Haven, CT 06516 USA
[3] Yale Univ, Sch Med, Nephrol Sect, W Haven, CT 06516 USA
[4] Univ Connecticut, Sch Med, Div Hypertens & Clin Pharmacol, Farmington, CT USA
[5] State Univ Rio de Janeiro, Div Nephrol, Rio De Janeiro, Brazil
[6] Hosp Privado Ctr Med Cordoba, Nephrol Sect, Cordoba, Argentina
[7] Catholic Univ Cordoba, Cordoba, Argentina
关键词
ambulatory blood pressure (BP); blood pressure (BP) monitoring; reproducibility; hypertension; hemodialysis (HD);
D O I
10.1053/ajkd.2000.19100
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Ambulatory blood pressure monitoring (ABPM) has been increasingly used in hemodialysis (HD) practice and research; however, no study has evaluated the reproducibility of ABPM in this population. To address this question, we performed 48-hour interdialytic ABPM on 21 HD patients (mean age, 53 +/- 16 years; 7 women) on two different occasions 68 +/- 34 days (range, 30 to 154 days) apart. To qualify for the protocol, patients had to be at the same dry weight and on the same vasoactive drug regimen at both monitoring periods. BP was analyzed according to three different methods: isolated pre-HD and post-HD values, average pre-HD and post-HD values for the five HD sessions surrounding each monitoring period, and 48-hour interdialytic ABPM, Reproducibility was determined by analysis of the SD of the differences (SDD) between the two monitoring periods and the coefficient of variation of each method of BP determination. Our results show better reproducibility of ABPM (SDD, 10.6/6.6 mm Hg; coefficient of variation, 7.5%/8.1%) compared with isolated pre-HD BP (SDD, 24.4/11.3 mm Hg; coefficient of variation, 16.7%/14.1%) or post-HD BP (SDD, 16.8/14.5 mm Hg; coefficient of variation, 11.7%/17.8%), and averaged pre HD BP (SDD, 14.7/7.2 mm Hg; coefficient of variation, 10.1%/9.1%) or post-HD BP (SDD, 12.4/8.7 mm Hg; coefficient of variation, 8.9%/11.1%). The reproducibility of the decrease in BP during sleep was poor, with up to 43% of the subjects changing dipping category within or between interdialytic periods. We conclude that ABPM is the most accurate method to study BP in HD patients over time. However, variability is significant, and there is poor reproducibility of the nocturnal decline in BP. (C) 2000 by the National Kidney Foundation, Inc.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 50 条
  • [1] Ambulatory blood pressure monitoring in hemodialysis patients
    Elisaf, M
    Pappas, H
    Kalaitzidis, R
    Katopodis, K
    Theodorou, J
    Siamopoulos, KC
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1996, 10 : S43 - S47
  • [2] AMBULATORY BLOOD-PRESSURE MONITORING - REPRODUCIBILITY IN 25 PATIENTS
    VAISSE, B
    BERNARD, F
    DRIVET, J
    SERRADIMIGNI, A
    POGGI, L
    [J]. JOURNAL OF HYPERTENSION, 1986, 4 (05) : 654 - 654
  • [3] The reproducibility of ambulatory blood pressure monitoring data
    Gorbunov, VM
    Deev, AD
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S165 - S165
  • [4] AMBULATORY BLOOD-PRESSURE MONITORING IN HEMODIALYSIS-PATIENTS
    KATZ, LA
    GREENBLATT, HA
    DIXON, JD
    RUBLER, S
    [J]. KIDNEY INTERNATIONAL, 1981, 19 (01) : 151 - 151
  • [5] Ambulatory Blood Pressure Monitoring in Hemodialysis Patients with Intradialytic Hypertension
    Shafiee, Maryam
    Jahromi, Shahrokh Ezzatzadegan
    Jalali, Ghanbar Ali Raiss
    [J]. IRANIAN JOURNAL OF KIDNEY DISEASES, 2020, 14 (02) : 126 - 132
  • [6] AMBULATORY BLOOD-PRESSURE MONITORING - REPRODUCIBILITY OVER 25 PATIENTS
    VAISSE, B
    BERNARD, F
    PERRINDRIVET, J
    SERRADIMIGNI, A
    POGGI, L
    [J]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1986, 79 (06): : 907 - 912
  • [7] Reproducibility of ambulatory blood pressure monitoring in patients with coronary heart disease
    Roas, S.
    Sudano, I.
    Enseleit, F.
    Kaiser, P.
    Hirt, A.
    Luscher, T. F.
    Ruschitzka, F.
    Noll, G.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 904 - 904
  • [8] REPRODUCIBILITY OF BLOOD PRESSURE PHENOTYPES BY MEANS OF AMBULATORY BLOOD PRESSURE MONITORING
    Lykka, A.
    Manousopoulos, K.
    Michas, F.
    Koroboki, E.
    Dimitriou, A.
    Zakopoulos, N.
    Manios, E.
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E265 - E265
  • [9] Ambulatory blood pressure monitoring in hemodialysis patients: A critique and literature review
    Covic, A
    Haydar, AA
    Goldsmith, D
    [J]. SEMINARS IN DIALYSIS, 2004, 17 (04) : 255 - 259
  • [10] Reproducibility of ambulatory blood pressure monitoring in daily practice
    van der Steen, MS
    Lenders, JWM
    Graafsma, SJ
    den Arend, J
    Thien, T
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (05) : 303 - 308