Effect of the humidification device on the work of breathing during noninvasive ventilation

被引:82
|
作者
Lellouche, FO
Maggiore, SM
Deye, N
Taillé, S
Pigeot, J
Harf, A
Brochard, L
机构
[1] Univ Paris 12, Hop Henri Mondor, AP HP, Med Intens Care Unit, F-94010 Creteil, France
[2] INSERM, U492, F-94010 Creteil, France
关键词
heat and moisture exchanger; heated humidifier; noninvasive ventilation; work of breathing;
D O I
10.1007/s00134-002-1518-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Heat and moisture exchangers (HME) increase circuitry deadspace compared to heated humidifiers (HH). This study compared the effect of HH and HME during noninvasive ventilation (NIV) on arterial blood gases and patient's effort assessed by respiratory muscles pressure-time product and by work of breathing (WOB). Design and setting: Randomized cross-over study in a medical intensive care unit. Patients: Nine patients receiving NIV for moderate to severe acute hypercapnic respiratory failure. Measurements: HME was randomly compared to HH during periods of 20 min. Each device was studied without (ZEEP) and with a PEEP of 5 cmH(2)O. At the end of each period arterial blood gases, ventilatory parameters, oesophageal and gastric pressures were recorded and indexes of patient's effort calculated. Results: Minute ventilation was significantly higher with HME than with HH (ZEEP: 15.8 +/- 3.7 vs. 12.8 +/- 3.6 l/min) despite a similar PaCO2 (60 +/- 16 vs. 57 +/- 16 mmHg). HME was associated with a greater increase in WOB (ZEEP: 15.5 +/- 7.7 vs. 8.4 +/- 4.5 J/min and PEEP: 11.3 +/- 5.7 vs. 7.3 +/- 3.8 J/min) and indexes of patient effort. NIV with HME failed to decrease WOB compared to baseline. Addition of PEEP reduced the level of effort, but similar differences between HME and HH were observed. Conclusions: In patients receiving NIV for moderate to severe acute hypercapnic respiratory failure, the use of HME lessens the efficacy of NIV in reducing effort compared to HH.
引用
收藏
页码:1582 / 1589
页数:8
相关论文
共 50 条
  • [1] Effect of the humidification device on the work of breathing during noninvasive ventilation
    François Lellouche
    Salvatore M. Maggiore
    Nicolas Deye
    Solenne Taillé
    Jérôme Pigeot
    Alain Harf
    Laurent Brochard
    Intensive Care Medicine, 2002, 28 : 1582 - 1589
  • [2] Influence of the humidification device on the work of breathing (WOB) during non-invasive ventilation (NIV)
    Lellouche, F
    Maggiore, SM
    Deye, N
    Taille, S
    Pigeot, J
    Fischler, M
    Harf, A
    Brochard, L
    INTENSIVE CARE MEDICINE, 2001, 27 : S245 - S245
  • [3] Humidification and noninvasive ventilation
    Solomita, Mario
    Smaldone, Gerald C.
    RESPIRATORY CARE, 2007, 52 (01) : 24 - 25
  • [4] Is Humidification Always Necessary During Noninvasive Ventilation in the Hospital?
    Chiumello, Davide
    RESPIRATORY CARE, 2010, 55 (07) : 950 - 950
  • [5] Humidification During Invasive and Noninvasive Mechanical Ventilation: 2012
    Restrepo, Ruben D.
    Walsh, Brian K.
    RESPIRATORY CARE, 2012, 57 (05) : 782 - 788
  • [6] Influence of Humidification on Comfort During Noninvasive Ventilation With a Helmet
    Ueta, Kazuyoshi
    Tomita, Toshiji
    Uchiyama, Akinori
    Ohta, Noriyuki
    Iguchi, Naoya
    Goto, Yukiko
    Fujin, Yuji
    RESPIRATORY CARE, 2013, 58 (05) : 798 - 804
  • [7] Is Humidification Always Necessary During Noninvasive Ventilation in the Hospital?
    Branson, Richard D.
    Gentile, Michael A.
    RESPIRATORY CARE, 2010, 55 (02) : 209 - 216
  • [8] Noninvasive ventilation and humidification of the airways
    Girault, C
    REVUE DES MALADIES RESPIRATOIRES, 2004, 21 (05) : S176 - S177
  • [9] DEVICE FOR HUMIDIFICATION AND CONTROLLED OXYGENATION DURING SPONTANEOUS BREATHING
    TALSMA, P
    OPTROODT, N
    HAVILL, JH
    ANAESTHESIA AND INTENSIVE CARE, 1978, 6 (02) : 160 - 161
  • [10] Influence of noninvasive ventilation on the work of breathing in obesity.
    Pankow, W
    Hijjeh, N
    Schuttler, F
    Penzel, T
    Peter, JH
    vonWichert, P
    MEDIZINISCHE KLINIK, 1997, 92 (01) : 54 - 60