IOT based portable heart rate and SpO2 pulse oximeter

被引:16
|
作者
Ganesh, Kakumanu Vamsi Sree Sai [1 ]
Jeyanth, S. P. Shibu [2 ]
Bevi, A. Ruhan [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Commun Engn, Chennai, India
[2] SRM Inst Sci & Technol, Dept Mech Engn, Chennai, India
来源
HARDWAREX | 2022年 / 11卷
关键词
IOT Based pulse oximeter; WeMos D1 mini-ESP8266; MAX; 30; 100; COVID-19; SpO2;
D O I
10.1016/j.ohx.2022.e00309
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ever since the COVID-19 pandemic, the necessity of new,innovative medical devices to analyse and monitor the situation has become profound. With this in mind, we have developed an IOT based portable and cost-efficient heart rate and SpO2/level sensor device with efficient performance. The proposed system is equipped with an onboard OLED with simple internet connectivity, which publishes data on the OLED and to a HTML webpage. The salient features include its portability, user compatibility and is unique in its way of transmitting collected data online, making it achieve better results than the current available solutions in various ways. The system has on board a MAX30100 sensor(Pulse Oximeter sensor) and along with the IOT based microcontroller(WeMos D1 mini) enables the facility to monitor the real time health data of patients in real-time through a HTML page. (c) 2022 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The use of pulse oximeter functional testers in evaluating Spo2 accuracy
    Mannheimer, PD
    Batchelder, PB
    Larsen, M
    Gehring, H
    Konecny, E
    ANESTHESIA AND ANALGESIA, 2004, 99 (06): : 1871 - 1871
  • [2] A Study of LoRa Performance in Monitoring of Patient's SPO2 and Heart Rate based IoT
    Adi, Puput Dani Prasetyo
    Kitagawa, Akio
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2020, 11 (02) : 238 - 251
  • [3] A Comparison of Finger Pulse Oximeter and SET-Based Neonatal Pulse Oximeter in Neonates in Terms of SpO2 Values and Response Time
    Anilkumar M. Khamkar
    P. D. Pote
    Georgeena Elsa Jose
    Indian Journal of Pediatrics, 2022, 89 : 1120 - 1122
  • [4] A Comparison of Finger Pulse Oximeter and SET-Based Neonatal Pulse Oximeter in Neonates in Terms of SpO2 Values and Response Time
    Khamkar, Anilkumar M.
    Pote, P. D.
    Jose, Georgeena Elsa
    INDIAN JOURNAL OF PEDIATRICS, 2022, 89 (11): : 1120 - 1122
  • [5] A Patch-Type Wireless Forehead Pulse Oximeter for SpO2 Measurement
    Azhari, A.
    Yoshimoto, S.
    Nezu, T.
    Iida, H.
    Ota, H.
    Noda, Y.
    Araki, T.
    Uemura, T.
    Sekitani, T.
    Morii, K.
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [6] IoT Health Monitoring Device of Oxygen Saturation (SpO2) and Heart Rate Level
    Tham, O. Y.
    Markom, M. A.
    Abu Bakar, A. H.
    Tan, E. S. Mohd Muslim
    Markom, A. M.
    2020 1ST INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, ADVANCED MECHANICAL AND ELECTRICAL ENGINEERING (ICITAMEE 2020), 2020, : 128 - 133
  • [7] Special Study of Earlobe Pulse Oximeter Using MAX30100 for Detecting SpO2 and Heart Beat
    Esmaeiliazad, Tina
    MEDICINA BALEAR, 2021, 36 (04): : 43 - 47
  • [8] Impact of SpO2 Targets and Pulse Oximeter Brand on Oxygen Flow Requirements and Oxygenation
    Lellouche, Francois
    Bouchard, Pierre-Alexandre
    Branson, Richard D.
    RESPIRATORY CARE, 2024, 69 (01) : 110 - 113
  • [9] The influence of hydrogen ion concentration and haemoglobin concentration on the accuracy of the pulse oximeter (Spo2)
    Perkins, GD
    Giles, S
    McAuley, DF
    Routeledge, H
    Gao, F
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (02) : 360P - 361P
  • [10] Wearable Device for Acquisition of SpO2 and Heart Rate
    Aleixo, Andre F. P.
    Lima, Euller G.
    Leite, Erico C.
    Inocencio, Ana V. M.
    Lins, Lucas T.
    Rodrigues, Marco A. B.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL 1, 2019, 70 (01): : 577 - 582