Ultrasensitive aptamer biosensor for arsenic (III) detection based on label-free triple-helix molecular switch and fluorescence sensing platform

被引:40
|
作者
Pan, Jiafeng [1 ]
Li, Qiong [1 ,2 ]
Zhou, Danhua [1 ,3 ]
Chen, Junhua [1 ]
机构
[1] Guangdong Inst Ecoenvironm Sci & Technol, Guangdong Key Lab Integrated Agroenvironm Pollut, Guangzhou 510650, Guangdong, Peoples R China
[2] Hunan Agr Univ, Coll Biosci & Biotechnol, Changsha 410128, Hunan, Peoples R China
[3] South China Agr Univ, Coll Nat Resources & Environm, Guangzhou 510642, Guangdong, Peoples R China
关键词
Label-free; Exonuclease III-assisted signal amplification; Triple-helix molecular switch; 2-amino-5,6,7-trimethy1-1,8-naphthyridine; Aptamer biosensor; SIGNAL AMPLIFICATION; DNA DETECTION; QUANTUM DOTS; EXONUCLEASE; WATER; NANOPARTICLE; AGGREGATION; RECOGNITION; AS(III); ASSAY;
D O I
10.1016/j.talanta.2018.07.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arsenic ion is a well-known harmful heavy element widely existing in the environment. Arsenic pollution occurring frequently has become increasing a serious worldwide threat to human health and the environment. The development of sensitive and reliable methods to detect As3+ in water is of great importance to biochemical research and monitoring applications. Herein, a label-free fluorescence sensing platform was elaborately designed for As3+ monitoring using exonuclease III (Exo III)-assisted cascade target recycling amplification strategy. The triple-helix molecular switch was employed as the sensing element and 2-amino-5,6,7-trimethyl-1,8-naphthyridine was used as the signal indicator. The resulting biosensor is simple, ultrasensitive, and exhibits a limit of detection of 5 ng/L with high selectivity. Meanwhile, the proposed sensor is successfully applied to determination of As3+ in practical sample analysis (tap water, lake water and pond water). The results shown herein have important implications in the development of new fluorescent sensors for the fast, easy, and selective detection and quantification of As in water samples. More importantly, the proposed platform can be extended to detect other heavy metal ions with newly designed triple-helix molecular switch, as well as pesticide residue, antibiotic residues, and biomarkers by using aptamer sequences.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [1] Label-free triple-helix aptamer as sensing platform for "signal-on" fluorescent detection of thrombin
    Xu, Nan
    Wang, Quanbo
    Lei, Jianping
    Liu, Lin
    Ju, Huangxian
    TALANTA, 2015, 132 : 387 - 391
  • [2] Design of Aptamer-Based Sensing Platform Using Triple-Helix Molecular Switch
    Zheng, Jing
    Li, Jishan
    Jiang, Ying
    Jin, Jianyu
    Wang, Kemin
    Yang, Ronghua
    Tan, Weihong
    ANALYTICAL CHEMISTRY, 2011, 83 (17) : 6586 - 6592
  • [3] A signal on aptamer-based electrochemical sensing platform using a triple-helix molecular switch
    Du, Yudan
    Mao, Yinfei
    He, Xiaoxiao
    Wang, Kemin
    Yan, Genping
    Liu, Jinquan
    Wang, Yonghong
    ANALYTICAL METHODS, 2014, 6 (16) : 6294 - 6300
  • [4] A Novel Fluorescent Aptasensor for Arsenic(III) Detection Based on a Triple-Helix Molecular Switch
    Yuan, Min
    Yang, Ye
    Chau, Nguyen Thi Quynh
    Zhang, Qinqin
    Wu, Xiuxiu
    Chen, Jiaye
    Wu, Zhiwei
    Zhong, Heng
    Li, Yuanyuan
    Xu, Fei
    MOLECULES, 2023, 28 (05):
  • [5] Triple-Helix Molecular Switch Electrochemical Ratiometric Biosensor for Ultrasensitive Detection of Nucleic Acids
    Xiong, Erhu
    Li, Zhenzhen
    Zhang, Xiaohua
    Zhou, Jiawan
    Yan, Xiaoxia
    Liu, Yunqing
    Chen, Jinhua
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 8830 - 8835
  • [6] Label-free fluorescent strategy for sensitive detection of tetracycline based on triple-helix molecular switch and G-quadruplex
    Chen, Tian-Xiao
    Ning, Feng
    Liu, Hai-Sheng
    Wu, Ke-Feng
    Li, Wei
    Ma, Chang-Bei
    CHINESE CHEMICAL LETTERS, 2017, 28 (07) : 1380 - 1384
  • [7] Label-free fluorescent strategy for sensitive detection of tetracycline based on triple-helix molecular switch and G-quadruplex
    Tian-Xiao Chen
    Feng Ning
    Hai-Sheng Liu
    Ke-Feng Wu
    Wei Li
    Chang-Bei Ma
    Chinese Chemical Letters, 2017, 28 (07) : 1380 - 1384
  • [8] G-quadruplex-bridged triple-helix aptamer probe strategy: A label-free chemiluminescence biosensor for ochratoxin A
    Wang, Yonghong
    Fang, Zeyang
    Ning, Ge
    Mao, Shaoming
    Wu, Yaohui
    Wu, Shun
    Liu, Gao-Qiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 298
  • [9] Aptamer contained triple-helix molecular switch for rapid fluorescent sensing of acetamiprid
    Liu, Xin
    Li, Ying
    Liang, Jing
    Zhu, Wenyue
    Xu, Jingyue
    Su, Ruifang
    Yuan, Lei
    Sun, Chunyan
    TALANTA, 2016, 160 : 99 - 105
  • [10] A novel colorimetric triple-helix molecular switch aptasensor for ultrasensitive detection of tetracycline
    Ramezani, Mohammad
    Danesh, Noor Mohammad
    Lavaee, Parirokh
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 181 - 187