Brain source localization using reduced EEG sensors

被引:14
|
作者
Jatoi, Munsif Ali [1 ]
Kamel, Nidal [2 ]
机构
[1] Benazir Bhutto Shaheed Univ Technol & Skill Dev, Dept Elect Engn Technol, Khairpur, Sindh, Pakistan
[2] Univ Teknol PETRONAS, Dept Elect & Elect Engn, Ctr Intelligent Signal & Imaging Res, Seri Iskandar, Perak, Malaysia
关键词
Electroencephalography; Source localization; Electrode reduction; Multiple sparse priors; Free energy; Localization error; SOURCE RECONSTRUCTION; FREE-ENERGY; SLORETA;
D O I
10.1007/s11760-018-1298-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Brain source activation is caused due to certain mental or physical task, and such activation is localized by using various optimization techniques. This localization has vital application for diagnoses of various brain disorders such as epilepsy, schizophrenia, Alzheimer, depression, Parkinson and stress. Various neuroimaging techniques (such as EEG, fMRI, MEG) are used to record brain activity for inference and estimation of active source locations. EEG employs set of sensors which are placed on scalp to measure electric potentials. These sensors have significant role in overall system complexity, computational time and system cost. Hence, sensor reduction for EEG source localization has been a topic of interest for researchers to develop a system with improved localization precision, less system complexity and reduced cost. This research work discusses and implements the brain source localization for real-time and synthetically generated EEG dataset with reduced number of sensors. For this, various optimization algorithms are used which include Bayesian framework-based multiple sparse priors (MSP), classical low-resolution brain electromagnetic tomography (LORETA), beamformer and minimum norm estimation (MNE). The results obtained are then compared in terms of negative variational free energy, localization error and computational time measured in seconds. It is observed that multiple sparse priors (MSP) with increased number of patches performed best even with reduced number of sensors, i.e., 7 instead of 74. The results are shown valid for synthetic EEG data at low SNR level, i.e., 5dB and real-time EEG data, respectively.
引用
收藏
页码:1447 / 1454
页数:8
相关论文
共 50 条
  • [1] Brain source localization using reduced EEG sensors
    Munsif Ali Jatoi
    Nidal Kamel
    Signal, Image and Video Processing, 2018, 12 : 1447 - 1454
  • [2] EEG-based brain source localization using visual stimuli
    Jatoi, Munsif Ali
    Kamel, Nidal
    Malik, Aamir Saeed
    Faye, Ibrahima
    Bornot, Jose M.
    Begum, Tahamina
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2016, 26 (01) : 55 - 64
  • [3] EEG source localization for two dipoles in the brain using a combined method
    Li, ZM
    Zhang, Y
    Zhang, QY
    Akutagawa, M
    Nagashino, H
    Shichijo, F
    Kinouchi, Y
    INTELLIGENT DATA ENGINEERING AND AUTOMATED LEARNING IDEAL 2005, PROCEEDINGS, 2005, 3578 : 171 - 178
  • [4] Accuracy of EEG dipole source localization using implanted sources in the human brain
    Krings, T
    Chiappa, KH
    Cuffin, BN
    Cochius, JI
    Connolly, S
    Cosgrove, GR
    CLINICAL NEUROPHYSIOLOGY, 1999, 110 (01) : 106 - 114
  • [5] Brain Source Localization Techniques: Evaluation Study Using Simulated EEG Data
    Hyder, Rasha
    Kamel, Nidal
    Tang, Tong Boon
    Bornot, Jose
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 942 - 947
  • [6] EEG Signals based Brain Source Localization Approaches
    Gaho, Anwar Ali
    Musavi, Sayed Hyder Abbas
    Jatoi, Munsif Ali
    Shafiq, Muhammad
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2018, 9 (09) : 253 - 261
  • [7] Comparison of Machine Learning Techniques Based Brain Source Localization Using EEG Signals
    Jatoi, Munsif Ali
    Dharejo, Fayaz Ali
    Teevino, Sadam Hussain
    CURRENT MEDICAL IMAGING, 2021, 17 (01) : 64 - 72
  • [8] Bayesian Framework based Brain Source Localization Using High SNR EEG Data
    Jatoi, Munsif Ali
    Kamel, Nidal
    Gaho, Anwar Ali
    Dharejo, Fayaz Ali
    2018 5TH IEEE INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGIES AND APPLIED SCIENCES (IEEE ICETAS), 2018,
  • [9] Effects of using different head models of brain tumor on accuracy of EEG source localization
    Hahm, JH
    Lee, IB
    Lee, BR
    Park, KS
    Kim, MS
    Kwon, JS
    NEUROIMAGE, 2001, 13 (06) : S139 - S139
  • [10] Brain Mapping of Cortical Epileptogenic Zones and Their EEG Source Localization
    Gaho, Anwar Ali
    Jatoi, Munsif Ali
    Musavi, Sayed Hyder Abbas
    Shafiq, Muhammad
    2019 2ND INTERNATIONAL CONFERENCE ON COMPUTING, MATHEMATICS AND ENGINEERING TECHNOLOGIES (ICOMET), 2019,