Custom-fit kinematic alignment in total knee arthroplasty using PSI. The story of ShapeMatch technology

被引:0
|
作者
Calliess, T. [1 ]
Ettinger, M. [1 ]
Stukenborg-Colsmann, C. [1 ]
Windhagen, H. [1 ]
机构
[1] Med Hsch Hannover Annastift, Dept Endoprothet & Rekonstrukt Gelenkchirurg, Orthopad Klin, Anna von Borries Str 3, D-30449 Hannover, Germany
来源
ORTHOPADE | 2016年 / 45卷 / 04期
关键词
Primary total knee arthroplasty; Kinematic alignment; Review; Patient specific intruments; Stryker ShapeMatch (R); INSTRUMENTATION; TRIAL;
D O I
10.1007/s00132-016-3240-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The story of ShapeMatchA (R) custom-fit cutting guides for primary total knee arthroplasty (TKA) is special compared to other available techniques. First, it was the first such patient-specific instrument (PSI) on the market. Second, the underlying philosophy of kinematic alignment is unique compared to other competitors. Finally, it is the only PSI technique that has been withdrawn from the market. Objectives and methods. The objective of this paper is to summarize the history of the ShapeMatchA (R) technology and to review the current literature regarding clinical evidence for kinematically aligned TKA. Results and conclusions. In the recent literature, faster rehabilitation, better knee function and higher patient satisfaction are described for kinematically aligned TKA compared to conventional alignment. However, there is also evidence for inaccuracies by using the PSI technology as a possible cause of treatment failures. Due to those problems, this technology was recalled from the market. As an alternative method to achieve kinematic alignment in TKA, manual as well as computer-assisted techniques are currently under development and are discussed here.
引用
收藏
页码:314 / +
页数:7
相关论文
共 50 条
  • [1] Patientenindividuelle kinematische Prothesenausrichtung per SchnittblocktechnikDie Chronik der ShapeMatch-TechnologieCustom-fit kinematic alignment in total knee arthroplasty using PSIThe story of ShapeMatch technology
    T. Calliess
    M. Ettinger
    C. Stukenborg-Colsmann
    H. Windhagen
    Der Orthopäde, 2016, 45 (4): : 314 - 321
  • [2] Bilateral Custom-fit Total Knee Arthroplasty in a Patient With Poliomyelitis
    Tardy, Nicolas
    Chambat, Pierre
    Murphy, Colin G.
    Fayard, Jean-Marie
    ORTHOPEDICS, 2014, 37 (09) : e839 - e843
  • [3] Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    Klatt, Brian A.
    Goyal, Nitin
    Austin, Matthew S.
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 26 - 29
  • [4] Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees
    Bali, Kamal
    Walker, Peter
    Bruce, Warwick
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1149 - 1154
  • [5] Custom-fit total knee arthroplasty: Our initial experience with 30 knees
    Bonicoli E.
    Andreani L.
    Parchi P.
    Piolanti N.
    Lisanti M.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1249 - 1254
  • [6] MRI enables custom-fit total knee replacement
    不详
    ADVANCED MATERIALS & PROCESSES, 2008, 166 (01): : 73 - 73
  • [7] Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    Howell, Stephen M.
    Kuznik, Kyle
    Hull, Maury L.
    Siston, Robert A.
    ORTHOPEDICS, 2008, 31 (09) : 857 - 863
  • [8] Kinematic alignment in total knee arthroplasty
    Nisar, Sohail
    Palan, Jeya
    Riviere, Charles
    Emerton, Mark
    Pandit, Hemant
    EFORT OPEN REVIEWS, 2020, 5 (07) : 380 - 390
  • [9] Kinematic alignment in total knee arthroplasty
    Weber, Patrick
    Gollwitzer, Hans
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2021, 33 (06): : 525 - 537
  • [10] Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes
    M. Pietsch
    O. Djahani
    Ch. Zweiger
    F. Plattner
    R. Radl
    Ch. Tschauner
    S. Hofmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2234 - 2240