Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air

被引:146
|
作者
Guo, Hai [1 ,2 ]
Morawska, Lidia [1 ]
He, Congrong [1 ]
Zhang, Yanli L. [2 ]
Ayoko, Godwin [1 ]
Cao, Min [1 ]
机构
[1] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[2] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Hong Kong, Hong Kong, Peoples R China
关键词
I/O ratios; Particle number concentration; PM2.5; Aitken mode particles; School; ACCUMULATION-MODE PARTICLES; ULTRAFINE PARTICLES; MASS CONCENTRATIONS; PARTICULATE MATTER; SIZE DISTRIBUTION; SUBMICROMETER PARTICLES; HOSPITAL ADMISSIONS; RESIDENTIAL HOUSES; CHILDREN; EXPOSURE;
D O I
10.1007/s11356-010-0306-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The impact of air pollution on school children's health is currently one of the key foci of international and national agencies. Of particular concern are ultrafine particles which are emitted in large quantities, contain large concentrations of toxins and are deposited deeply in the respiratory tract. In this study, an intensive sampling campaign of indoor and outdoor airborne particulate matter was carried out in a primary school in February 2006 to investigate indoor and outdoor particle number (PN) and mass concentrations (PM2.5), and particle size distribution, and to evaluate the influence of outdoor air pollution on the indoor air. For outdoor PN and PM2.5, early morning and late afternoon peaks were observed on weekdays, which are consistent with traffic rush hours, indicating the predominant effect of vehicular emissions. However, the temporal variations of outdoor PM2.5 and PN concentrations occasionally showed extremely high peaks, mainly due to human activities such as cigarette smoking and the operation of mower near the sampling site. The indoor PM2.5 level was mainly affected by the outdoor PM2.5 (r = 0.68, p < 0.01), whereas the indoor PN concentration had some association with outdoor PN values (r = 0.66, p < 0.01) even though the indoor PN concentration was occasionally influenced by indoor sources, such as cooking, cleaning and floor polishing activities. Correlation analysis indicated that the outdoor PM2.5 was inversely correlated with the indoor to outdoor PM2.5 ratio (I/O ratio; r = -0.49, p < 0.01), while the indoor PN had a weak correlation with the I/O ratio for PN (r = 0.34, p < 0.01). The results showed that occupancy did not cause any major changes to the modal structure of particle number and size distribution, even though the I/O ratio was different for different size classes. The I/O curves had a maximum value for particles with diameters of 100-400 nm under both occupied and unoccupied scenarios, whereas no significant difference in I/O ratio for PM2.5 was observed between occupied and unoccupied conditions. Inspection of the size-resolved I/O ratios in the preschool centre and the classroom suggested that the I/O ratio in the preschool centre was the highest for accumulation mode particles at 600 nm after school hours, whereas the average I/O ratios of both nucleation mode and accumulation mode particles in the classroom were much lower than those of Aitken mode particles. The findings obtained in this study are useful for epidemiological studies to estimate the total personal exposure of children, and to develop appropriate control strategies for minimising the adverse health effects on school children.
引用
收藏
页码:1268 / 1278
页数:11
相关论文
共 50 条
  • [1] Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air
    Hai Guo
    Lidia Morawska
    Congrong He
    Yanli L. Zhang
    Godwin Ayoko
    Min Cao
    [J]. Environmental Science and Pollution Research, 2010, 17 : 1268 - 1278
  • [2] Indoor and outdoor PM2.5 and PM10 concentrations in the air during a dust storm
    Kuo, Hsien-Wen
    Shen, Huna-Yi
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (03) : 610 - 614
  • [3] Outdoor PM2.5 air filtration: optimising indoor air quality and energy
    Belias, Evangelos
    Licina, Dusan
    [J]. BUILDINGS & CITIES, 2022, 3 (01): : 186 - 203
  • [4] Indoor/outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2
    Challoner, Avril
    Gill, Laurence
    [J]. BUILDING AND ENVIRONMENT, 2014, 80 : 159 - 173
  • [5] The Influence of Outdoor Particulate Matter PM2.5 on Indoor Air Quality: The Implementation of a New Assessment Method
    Bekierski, Dominik
    Kostyrko, Krystyna Barbara
    [J]. ENERGIES, 2021, 14 (19)
  • [6] The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom
    Branis, M
    Rezácová, P
    Domasová, M
    [J]. ENVIRONMENTAL RESEARCH, 2005, 99 (02) : 143 - 149
  • [7] Investigation of Indoor and Outdoor PM2.5 Pollution Situation in Beijing
    Wu, Yuqin
    Chen, Chao
    Du, Yuwei
    Chen, Ziguang
    Li, Yufan
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1223 - 1229
  • [8] On-bicycle exposure to particulate air pollution: Particle number, black carbon, PM2.5, and particle size
    Hankey, Steve
    Marshall, Julian D.
    [J]. ATMOSPHERIC ENVIRONMENT, 2015, 122 : 65 - 73
  • [9] Relations between indoor and outdoor PM2.5 and constituent concentrations
    Cong Liu
    Yinping Zhang
    [J]. Frontiers of Environmental Science & Engineering, 2019, 13
  • [10] Sources of indoor and outdoor PM2.5 concentrations in primary schools
    Amato, F.
    Rivas, I.
    Viana, M.
    Moreno, T.
    Bouso, L.
    Reche, C.
    Alvarez-Pedrerol, M.
    Alastuey, A.
    Sunyer, J.
    Querol, X.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 490 : 757 - 765