DEMAT: A multi-institutional dosimetry audit of rotational and static intensity-modulated radiotherapy

被引:12
|
作者
Lafond, Caroline [1 ]
Chiavassa, Sophie [2 ]
Bertaut, Cindy [1 ]
Boussion, Nicolas [3 ]
Chapel, Nathalie [4 ]
Chapron, Lucie [5 ]
Coste, Frederic [6 ]
Crespin, Sylvain [7 ]
Dy, Gilles [8 ]
Faye, Papa Abdoulaye [2 ]
Leleu, Cyril [9 ]
Bouvier, Jeanne [1 ]
Madec, Ludovic [10 ]
Mesgouez, Jerome [11 ]
Palisson, Jeremy [12 ]
Vela, Anthony [13 ]
Delpon, Gregory [2 ]
机构
[1] Ctr Eugene Marquis, F-35042 Rennes, France
[2] Ctr Rene Gauducheau, Inst Cancerol Ouest, F-44805 Nantes, France
[3] CHRU, F-29609 Brest, France
[4] Clin Pasteur, F-29200 Brest, France
[5] Clin Armoricaine, F-22000 St Brieuc, France
[6] Pole Mutualiste, F-44600 St Nazaire, France
[7] CHD Oudairies, F-85925 La Roche Sur Yon, France
[8] Clin St Vincent, F-35760 St Gregoire, France
[9] CHI, F-29000 Quimper, France
[10] Ctr Baie, F-50300 Avranches, France
[11] Ctr Paul Papin, Inst Cancerol Ouest, F-49100 Angers, France
[12] Ctr Mallet Proux, F-53000 Laval, France
[13] Ctr Francois Baclesse, F-14000 Caen, France
来源
关键词
IMRT; VMAT; Audit; TREATMENT PLANNING SYSTEMS; FILM DOSIMETRY; ARC THERAPY; DOSE DISTRIBUTIONS; VERIFICATION; CANCER;
D O I
10.1016/j.ejmp.2016.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Static beam intensity-modulated-radiation-therapy (IMRT) and/or Volumetric-Modulated-Arc-Therapy (VMAT) are now available in many regional radiotherapy departments. The aim of this multi-institutional audit was to design a new methodology based on radiochromic films to perform an independent quality control. Methods: A set of data were sent to all participating centres for two clinical localizations: prostate and Head and Neck (H&N) cancers. The agreement between calculations and measurements was verified in the Octavius phantom (PTW) by point measurements using ionization chambers and by 2D measurements using EBT3 radiochromic films. Due to uncertainties in the whole procedure, criteria were set to 5% and 3% in local dose and 3 mm in distance excluding doses lower than 10% of the maximum doses. No normalization point or area was used for the quantitative analysis. Results: 13 radiotherapy centres participated in this audit involving 28 plans (12 IMRT, 16 VMAT). For point measurements, mean errors were -0.18 +/- 1.54% and 0.00 +/- 1.58% for prostate and H&N cases respectively. For 2D measurements with 5%/3 mm criteria, gamma map analysis showed a pixel pass rate higher than 95% for prostate and H&N. Mean gamma index was lower than 0.4 for prostate and 0.5 for H&N. Both techniques yielded similar results. Conclusion: This study showed the feasibility of an independent quality control by peers for conventional IMRT and VMAT. Results from all participating centres were found to be in good agreement. This regional study demonstrated the feasibility of our new methodology based on radiochromic films without dose normalization on a specific point. (C) 2016 Associazione Italiana di Fisica Medica Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 50 条
  • [1] A multi-institutional dosimetry audit of rotational intensity-modulated radiotherapy
    Clark, Catharine H.
    Hussein, Mohammad
    Tsang, Yatman
    Thomas, Russell
    Wilkinson, Dean
    Bass, Graham
    Snaith, Julia
    Gouldstone, Clare
    Bolton, Steve
    Nutbrown, Rebecca
    Venables, Karen
    Nisbet, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 272 - 278
  • [2] Dosimetry study of two rotational intensity-modulated radiotherapy in esophageal cancer
    Bai, W.
    Qiao, X.
    Fan, X.
    Zhang, R.
    Qiu, R.
    Li, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S848 - S849
  • [3] Similarities between static and rotational intensity-modulated plans
    Wu, Q. Jackie
    Yin, Fang-Fang
    McMahon, Ryan
    Zhu, Xiaofeng
    Das, Shiva K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01): : 33 - 43
  • [4] Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification
    Sanchez-Doblado, Francisco
    Hartmann, Gunther H.
    Pena, Javier
    Capote, Roberto
    Paiusco, Marta
    Rhein, Bernhard
    Leal, Antonio
    Lagares, Juan Ignacio
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 301 - 310
  • [5] VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT
    Wu, Q. Jackie
    Yoo, Sua
    Kirkpatrick, John P.
    Thongphiew, Danthai
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1596 - 1604
  • [6] Multi-institutional feasibility study of intensity-modulated radiotherapy with chemotherapy for locally advanced non-small cell lung cancer
    Hideyuki Harada
    Shota Omori
    Keita Mori
    Masahiro Konno
    Haruyasu Murakami
    Toshiyuki Imagumbai
    Haruyuki Fukuda
    Kiyoshi Nakamatsu
    Tomoki Kimura
    Hiroaki Tanabe
    Hideki Fujita
    Hitoshi Tatebe
    Kazunori Fujitaka
    Yasumasa Nishimura
    International Journal of Clinical Oncology, 2022, 27 : 1025 - 1033
  • [7] Multi-institutional feasibility study of intensity-modulated radiotherapy with chemotherapy for locally advanced non-small cell lung cancer
    Harada, Hideyuki
    Omori, Shota
    Mori, Keita
    Konno, Masahiro
    Murakami, Haruyasu
    Imagumbai, Toshiyuki
    Fukuda, Haruyuki
    Nakamatsu, Kiyoshi
    Kimura, Tomoki
    Tanabe, Hiroaki
    Fujita, Hideki
    Tatebe, Hitoshi
    Fujitaka, Kazunori
    Nishimura, Yasumasa
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2022, 27 (06) : 1025 - 1033
  • [8] Intensity-modulated radiotherapy
    Leibel, SA
    Fuks, Z
    Zelefsky, MJ
    Wolden, SL
    Rosenzweig, KE
    Alektiar, KM
    Hunt, MA
    Yorke, ED
    Hong, LX
    Amols, HI
    Burman, CM
    Jackson, A
    Mageras, GS
    LoSasso, T
    Happersett, L
    Spirou, SV
    Chui, CS
    Ling, CC
    CANCER JOURNAL, 2002, 8 (02): : 164 - 176
  • [9] The role of complexity metrics in a multi-institutional dosimetry audit of VMAT
    Mcgarry, Conor K.
    Agnew, Christina E.
    Hussein, Mohammad
    Tsang, Yatman
    Mcwilliam, Alan
    Hounsell, Alan R.
    Clark, Catharine H.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1057):
  • [10] The role of complexity metrics in a multi-institutional dosimetry audit of VMAT
    Mc Garry, C. K.
    Agnew, C. E.
    Hussein, M.
    Tsang, Y.
    Hounsell, A. R.
    Clark, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S530 - S530