Parameter Optimization of Motion Artifact Canceling PPG-Based Heart Rate Sensor by Means of Cross Validation

被引:0
|
作者
Hara, Shinsuke [1 ]
Shimazaki, Takunori [1 ]
Okuhata, Hiroyuki [2 ]
Nakamura, Hajime [3 ]
Kawabata, Takashi [4 ]
Cai, Kai [1 ]
Takubo, Tomohito [1 ]
机构
[1] Osaka City Univ, Grad Sch Engn, Osaka, Japan
[2] Synth Corp, New York, NY USA
[3] Aihara Second Hosp, Sagamihara, Kanagawa, Japan
[4] Kansai Univ, Grad Sch Hlth & Well Being, Suita, Osaka, Japan
关键词
photoplethysmography; heart rate; motion artifact; outlier; leave-one-out cross valication;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photoplethysmography (PPG) is one of the simple and non-invasive heart rate (HR) sensing methods, but when applying it to a person during exercise, the output is contaminated with motion artifact (MA). Furthermore, when the pressure to stabilize the sensor on the skin surface is lower, extremely large values referred to as "outliers" are often observed in the sensed heart rate. To cancel the MA and reject the outliers, we have proposed an MA canceling PPG-based HR sensor, and have confirmed its effectivity for persons during vigorous exercises. However, the HR sensor contains several parameters to be adjusted to obtain better performance, although the number of experiments using subjects is limited due to its complexity. In this paper, we discuss a parameter optimization method for the MA canceling PPG-based HR sensor by means of cross validation. We apply the leave-one-out cross validation (LOOCV) to experimental data changing the values of the parameters, and then determine the ones which can minimize the root mean square error (RMSE). Finally, we show that the proposed HR sensor can achieve the RMSE of less than 7.1 beats per minute (bpm) for exercises of walking, running and jumping.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [1] Breathing Motion Artifact Cancellation in PPG-Based Heart Rate Sensing
    Shimazaki, Takunori
    Hara, Shinsuke
    [J]. 2015 9TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2015, : 200 - 203
  • [2] Motion Artifact Cancellation and Outlier Rejection for Clip-type PPG-Based Heart Rate Sensor
    Shimazaki, Takunori
    Hara, Shinsuke
    Okuhata, Hiroyuki
    Nakamura, Hajime
    Kawabata, Takashi
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 2026 - 2029
  • [3] Cancellation of Motion Artifact Induced by Exercise for PPG-Based Heart Rate Sensing
    Shimazaki, Takunori
    Hara, Shinsuke
    Okuhata, Hiroyuki
    Nakamura, Hajime
    Kawabata, Takashi
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3216 - 3219
  • [4] Motion Artifact Canceling PPG Heart Rate Sensor Based on an Adaptive Filter Algorithm with Variable Tap Length
    Kajita, Mizuki
    Hara, Shinsuke
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4410 - 4413
  • [5] Effect of Position and Fastening Belt Pressure on the Accuracy of PPG-Based Heart Rate Sensor
    Shimazaki, Takunori
    Kuwahara, Yuzu
    Kimoto, Masaya
    Hara, Shinsuke
    Yomo, Hiroyuki
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4323 - 4326
  • [6] Robust PPG-based Ambulatory Heart Rate Tracking Algorithm
    Huang, Nicholas
    Selvaraj, Nandakumar
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5929 - 5934
  • [7] PPG-Based Heart Rate Estimation Using Unsupervised Domain Adaptation
    Kim, Jihyun
    Lee, Minjung
    Cho, Hansam
    Kim, Seoung Bum
    [J]. ADVANCES AND TRENDS IN ARTIFICIAL INTELLIGENCE: THEORY AND APPLICATIONS, IEA-AIE 2024, 2024, 14748 : 291 - 296
  • [8] A Robust PPG-based Heart Rate Monitor for Fitness and eHealth Applications
    Shokrekhodaei, Maryamsadat
    Quinones, Stella
    Martinek, Radek
    Nazeran, Homer
    [J]. 2018 IEEE 20TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2018,
  • [9] ROBUST REAL-TIME PPG-BASED HEART RATE MONITORING
    Nowak, Ewelina
    Krainski, Mateusz
    Rubinski, Maciej
    Pazderska, Marta
    Raczynski, Stanislaw A.
    [J]. 2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2561 - 2565
  • [10] NAS-PPG: PPG-Based Heart Rate Estimation Using Neural Architecture Search
    Song, Seok Bin
    Nam, Jung Woo
    Kim, Jin Heon
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (13) : 14941 - 14949