Bismuth-coated carbon electrodes for anodic stripping voltammetry

被引:927
|
作者
Wang, J [1 ]
Lu, JM [1 ]
Hocevar, SB [1 ]
Farias, PAM [1 ]
Ogorevc, B [1 ]
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
关键词
D O I
10.1021/ac000108x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bismuth-coated carbon electrodes display an attractive stripping voltammetric performance which compares favorably with that of common mercury-film electrodes. These bismuth-film electrodes are prepared by adding 400 mu g/L (ppb) bismuth(III) directly to the sample solution and simultanously depositing the bismuth and target metals on the glassy-carbon or carbon-fiber substrate. Stripping voltammetric measurements of microgram per liter levels of cadmium, lead, thallium, and zinc in nondeaerated solutions yielded well-defined peaks, along with a low background, following short deposition periods. Detection limit of 1.1 and 0.3 ppb lead are obtained following 2- and l0-min deposition, respectively, Changes in the peak potentials (compared to those observed at mercury electrodes) offer new selectivity dimensions, Scanning electron microscopy sheds useful insights into the different morphologies of the bismuth deposits on the carbon substrates, The in situ bismuth-plated electrodes exhibit a wide accessible potential window (- 1.2 to -0.2 V) that permits quantitation of most metals measured at mercury electrodes (except of copper, antimony, and bismuth itself). Numerous key experimental variables have been characterized and optimized, High reproducibility was indicated from the relative standard deviations (2.4 and 4.4%) for 22 repetitive measurements of 80 mu g/L cadmium and lead, respectively, Such an attractive use of "mercury-free", environmentally friendly electrodes (with a performance equivalent to that of mercury ones) offers great promise to centralized and decentralized testing of trace metals.
引用
收藏
页码:3218 / 3222
页数:5
相关论文
共 50 条
  • [1] Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples
    Baldo, MA
    Daniele, S
    [J]. ANALYTICAL LETTERS, 2004, 37 (05) : 995 - 1011
  • [2] Bismuth-Coated Iridium Microwire Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry
    Kyrisoglou, Christos
    Economou, Anastasios
    Efstathiou, Constantinos E.
    [J]. ELECTROANALYSIS, 2012, 24 (09) : 1825 - 1832
  • [3] Recent advances in anodic stripping voltammetry with bismuth-modified carbon paste electrodes
    Svancara, I
    Baldrianová, L
    Tesarová, E
    Hocevar, SB
    Elsuccary, SAA
    Economou, A
    Sotiropoulos, S
    Ogorevc, B
    Vytras, K
    [J]. ELECTROANALYSIS, 2006, 18 (02) : 177 - 185
  • [4] Bismuth-Coated Reticulated Vitreous Carbon and Bismuth-Coated Glassy Carbon Electrodes for On-Line Coupling of ASV with ICP-MS
    Liu, Lin
    Do, Huy N. L.
    Wang, Jianxiu
    Zhou, Feimeng
    [J]. ELECTROANALYSIS, 2010, 22 (13) : 1476 - 1482
  • [5] Anodic stripping voltammetry of antimony at unmodified carbon electrodes
    Lu, Min
    Toghill, Kathryn E.
    Phillips, Michael A.
    Compton, Richard G.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (02) : 213 - 227
  • [6] Electrodes with extremely high hydrogen overvoltages as substrate electrodes for stripping analysis based on bismuth-coated electrodes
    Tian, Ye
    Hu, Lianzhe
    Han, Shuang
    Yuan, Yali
    Wang, Jianguo
    Xu, Guobao
    [J]. ANALYTICA CHIMICA ACTA, 2012, 738 : 41 - 44
  • [7] Zinc Detection in Serum by Anodic Stripping Voltammetry on Microfabricated Bismuth Electrodes
    Jothimuthu, Preetha
    Wilson, Robert A.
    Herren, Josi
    Pei, Xing
    Kang, Wenjing
    Daniels, Rodney
    Wong, Hector
    Beyette, Fred
    Heineman, William R.
    Papautsky, Ian
    [J]. ELECTROANALYSIS, 2013, 25 (02) : 401 - 407
  • [8] Porous Bismuth Film Electrodes for Signal Increase in Anodic Stripping Voltammetry
    Urbanova, Veronika
    Bartos, Martin
    Vytras, Karel
    Kuhn, Alexander
    [J]. ELECTROANALYSIS, 2010, 22 (13) : 1524 - 1530
  • [9] Bismuth-coated screen-printed electrodes for stripping voltammetric measurements of trace lead
    Wang, J
    Lu, JM
    Hocevar, SB
    Ogorevc, B
    [J]. ELECTROANALYSIS, 2001, 13 (01) : 13 - 16
  • [10] APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY
    HOYER, B
    FLORENCE, TM
    BATLEY, GE
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (13) : 1608 - 1614