Electrochemical and SEM characterization of gold-coated stents in vitro

被引:5
|
作者
Shih, Chun-Che [1 ]
Shih, Chun-Ming
Chou, Kuang-Yi
Lin, Shing-Jong
Su, Yea-Yang
机构
[1] Natl Yang Ming Univ, Inst Clin Med, Sch Med, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[3] Taipei Vet Gen Hosp, Div Cardiovasc Surg, Taipei 112, Taiwan
[4] Taipei Vet Gen Hosp, Div Cardiol, Taipei 112, Taiwan
[5] Natl Taipei Coll Nursing, Ctr Gen Educ, Taipei 112, Taiwan
[6] Taipei Med Univ, Sch Med, Taipei 110, Taiwan
关键词
D O I
10.1149/1.2724237
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The inert properties of gold make it a useful material for implants. Gold was applied as a coating on 316L stainless steel stents to improve the radiopacity and to provide better thrombogenic resistance and a lower degree of restenosis after deployment. Reports of clinical trials using gold-coated stents showed controversial results. A detailed examination of gold-coated stents was designed to understand the influence of surface conditions on the electrochemical properties in vitro. Corrosion resistance of gold-coated stents was investigated by cyclic polarization, and potentiostatic control. Surface morphologies of gold-coated stents in as-received condition, postinflated condition, and after cyclic polarization were characterized by scanning electron spectroscopy (SES). X-ray mapping identified elemental distribution. Results found severe defects in the gold-coating in the as-received condition, cracks and wrinkles on inflated gold-coated stents, and severe corrosion after cyclic polarization. Leaching of metallic ions in Ringer's solution was possible. (c) 2007 The Electrochemical Society.
引用
收藏
页码:C326 / C330
页数:5
相关论文
共 50 条
  • [1] Gold-coated stents study reports
    不详
    GOLD BULLETIN, 2006, 39 (03): : 132 - 132
  • [2] Restenosis in gold-coated renal artery stents
    Nolan, BW
    Schermerhorn, ML
    Powell, RJ
    Rowell, E
    Fillinger, MF
    Rzucidlo, EM
    Wyers, MC
    Whittaker, D
    Zwolak, RM
    Walsh, DB
    Cronenwett, JL
    JOURNAL OF VASCULAR SURGERY, 2005, 42 (01) : 40 - 46
  • [3] Gold-coated versus uncoated stents: An intravascular ultrasound volumetric analysis showing an increase in intimal hyperplasia in gold-coated stents
    Abizaid, AS
    Abizaid, A
    Mattos, I
    Mintz, GS
    Stalco, R
    Costa, M
    Seixas, AC
    de Paula, JE
    Chaves, A
    Centemero, M
    Tanajura, LF
    Mahran, R
    Sousa, A
    Sousa, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 60A - 60A
  • [4] Biocompatibility comparison of stainless steel, gold-coated, and heat-treated gold-coated endovascular stents
    Morss, AS
    Seifert, P
    Groothius, A
    Bornstein, D
    Rogers, C
    Edelman, ER
    ADVANCED BIOMATERIALS-CHARACTERIZATION, TISSUE ENGINEERING AND COMPLEXITY, 2002, 711 : 5 - 10
  • [5] Gold-coated NIR stents in porcine coronary arteries
    Edelman, ER
    Seifert, P
    Groothuis, A
    Morss, A
    Bornstein, D
    Rogers, C
    CIRCULATION, 2001, 103 (03) : 429 - 434
  • [6] Increased risk of restenosis after placement of gold-coated stents
    Gehman, S
    CIRCULATION, 2001, 104 (05) : E23 - E23
  • [7] Increased risk of restenosis after placement of gold-coated stents -: Results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease
    Kastrati, A
    Schömig, A
    Dirschinger, J
    Mehilli, J
    von Welser, N
    Pache, J
    Schühlen, H
    Schilling, T
    Schmitt, C
    Neumann, FJ
    CIRCULATION, 2000, 101 (21) : 2478 - 2483
  • [8] Fabrication and characterization of gold-coated iron nanoparticles
    Cho, SJ
    Kauzlarich, SM
    Liu, K
    Long, GJ
    Grandjean, F
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U45 - U45
  • [9] SEM/EDS evaluation of porcelain adherence to gold-coated cast titanium
    Lee, KM
    Cai, Z
    Griggs, JA
    Guiatas, L
    Lee, DJ
    Okabe, T
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 68B (02) : 165 - 173
  • [10] Comparison of gold-coated NIR stents with uncoated NIR stents in patients with coronary artery disease
    Park, SJ
    Lee, CW
    Hong, MK
    Kim, JJ
    Park, SW
    Tahk, SJ
    Jang, YS
    Seung, KB
    Yang, JY
    Jeong, MH
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (07): : 872 - +