Experimental Investigation of a Flat-Plate Closed-Loop Pulsating Heat Pipe

被引:16
|
作者
Wits, Wessel W. [1 ,2 ,3 ]
Groeneveld, Gerben [3 ]
van Gerner, Henk Jan [2 ]
机构
[1] Thales Netherlands, POB 42, NL-7550 GD Hengelo, Netherlands
[2] Netherlands Aerosp Ctr NLR, POB 153, NL-8300 AD Emmeloord, Netherlands
[3] Univ Twente, Fac Engn Technol, POB 217, NL-7500 AE Enschede, Netherlands
来源
关键词
THERMAL PERFORMANCE;
D O I
10.1115/1.4042367
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal performance and operating modi of a flat-plate closed-loop pulsating heat pipe (PHP) are experimentally observed. The PHP is manufactured through computer numerical controlled milling and vacuum brazing of stainless steel 316 L. Next to a plain closed-loop PHP, also one that promotes fluid circulation through passive Tesla-type valves was developed. Each channel has a 2 x 2 mm(2) square cross section, and in total, 12 parallel channels fit within the 50 x 200 mm(2) effective area. During the experimental investigation, the power input was increased from 20 W to 100 W, while cooling was performed using a thermo-electric cooler (TEC) and thermostat bath. Three working fluids were assessed: water, methanol, and ammonia. The PHP was charged with a 40% filling ratio. Thermal resistances were obtained for different inclination angles. It was observed that the PHP operates well in vertical evaporator-down orientation but not horizontally. Moreover, experiments show that the minimum operating orientation is between 15 and 30 deg. Two operating modi are observed, namely, the thermosyphon modus, without excessive fluctuations, and the pulsating modus, in which both the temperature and pressure responses oscillate frequently and violently. Overall thermal resistances were determined as low as 0.15 K/W (ammonia) up to 0.28 and 0.48 K/W (water and methanol, respectively) at a power input of 100 W in the vertical evaporator-down orientation. Infrared thermography was used to visualize the working fluid behavior within the PHPs. Infrared observations correlated well with temperature and pressure measurements. The experimental results demonstrated that the developed flat-plate PHP design, suitable for high-volume production, is a promising candidate for electronics cooling applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Experimental investigation of flat plate closed loop pulsating heat pipe
    Srikrishna, P.
    Siddharth, N.
    Reddy, S. U. M.
    Narasimham, G. S. V. L.
    [J]. HEAT AND MASS TRANSFER, 2019, 55 (09) : 2637 - 2649
  • [2] Experimental investigation of flat plate closed loop pulsating heat pipe
    P. Srikrishna
    N. Siddharth
    S. U. M. Reddy
    G. S. V. L. Narasimham
    [J]. Heat and Mass Transfer, 2019, 55 : 2637 - 2649
  • [3] Experimental investigation of the thermal management of flat-plate closed-loop pulsating heat pipes with interconnecting channels
    Ebrahimi, M.
    Shafii, M. B.
    Bijarchi, M. A.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 838 - 847
  • [4] A Simple Model Used to Predict the Thermal Performance of Flat-Plate Closed-Loop Pulsating Heat Pipe
    Wu, Qingping
    Wang, Ruxiang
    Liu, Xiaopeng
    Li, Yajun
    Xu, Rongji
    Li, Yanzhong
    [J]. ENERGY ENGINEERING AND ENVIRONMENTAL ENGINEERING, PTS 1AND 2, 2013, 316-317 : 7 - +
  • [5] Experimental investigation of the effect of using closed-loop pulsating heat pipe on the performance of a flat plate solar collector
    Kargarsharifabad, H.
    Mamouri, S. Jahangiri
    Shafii, M. B.
    Rahni, M. Taeibi
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (01)
  • [6] An Experimental Study towards the Practical Application of Closed-Loop Flat-Plate Pulsating Heat Pipes
    Groeneveld, Gerben
    van Gerner, Henk-jan
    Wits, Wessel W.
    [J]. 2017 23RD INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC), 2017,
  • [7] Thermofluid dynamic study of flat-plate closed-loop pulsating heat pipes
    Khandekar, S
    Schneider, M
    Schäfer, P
    Kulenovic, R
    Groll, M
    [J]. MICROSCALE THERMOPHYSICAL ENGINEERING, 2002, 6 (04): : 303 - 317
  • [8] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    [J]. APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [9] Experimental Investigation of Thermal Resistance of a Ferrofluidic Closed-Loop Pulsating Heat Pipe
    Mohammadi, Maziar
    Mohammadi, Mohammad
    Ghahremani, Amir R.
    Shafii, Mohammad B.
    Mohammadi, Niloofar
    [J]. HEAT TRANSFER ENGINEERING, 2014, 35 (01) : 25 - 33
  • [10] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    [J]. APPLIED THERMAL ENGINEERING, 2019, 160