Development, validation, and implementation of a multiplex immunoassay for the simultaneous determination of five cytokines in human serum

被引:105
|
作者
Ray, CA [1 ]
Bowsher, RR
Smith, WC
Devanarayan, V
Willey, MB
Brandt, JT
Dean, RA
机构
[1] Eli Lilly & Co, Lilly Corp Ctr, Lilly Res Labs, Expt Med Lab, Indianapolis, IN 46285 USA
[2] Eli Lilly & Co, Lilly Res Labs, Greenfield, IN 46140 USA
关键词
multiplex; LabMAP; microsphere; fluorescence; immunoassay; cytokines; analytical validation;
D O I
10.1016/j.jpba.2004.05.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of biomarkers can provide important information about the safety and efficacy of candidate drugs. Unfortunately. limited sample volume and excess costs often limit analysis of multiple biomarkers. We developed, optimized, validated, and implemented a multiplex immunoassay for simultaneous measurement of multiple circulating cytokines: IL-1beta, TNFalpha, IL-6. IL-8. and IL-10. Multiplex immuoassays were performed using the Luminex LabMAP instrument. Capture antibodies for each cytokine were. covalently bound to distinct microsphere subsets distinguished by differing dye ratios. The concentration of each individual cytokine determined by measuring orange fluorescence produced by a complex of a biotinylated cytokine-specific antibody and streptavidin-phycoerythrin. The lower limit of quantification for all assays was 20 pg/mL with the exception of IL-8 which was 100 pg/mL. The inter-assay precision was less than 25%CV for all analytes at all control levels both pre-study and in-study. The percent recovery ranged from 83 to 108% pre-study and 90 to 125% in-study. In a linearity assessment, a 15,000 pg/mL multi-analyte control could be diluted 1:50 and maintain expected accuracy. We measured the cytokine concentrations in more than 2000 serum samples from patients with sepsis. Multiplex results for IL-6 were compared to a conventional commercially available ELISA kit. The degree of agreement between the two methods as measured by the concordance Correlation coefficient was 84.5%. Multiplex results were 2.36-fold higher than ELISA values on the average. After adjusting for this mean difference, the 95% empirical limits of agreement for the ratio of individual sample values were 0.33, 2.65. This multiplex immunoassay provided simultaneous measurement of circulating cytokines using 30% less patient specimen compared to traditional approaches and at a significantly decreased cost. Efficient use of this platform requires process improvements to hilly maximize the positive impact of multiplex assays in clinical drug development. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 50 条
  • [1] Development and validation of a multiplex immunoassay for the simultaneous determination of serum antibodies to Bordetella pertussis, diphtheria and tetanus
    van Gageldonk, Pieter G. M.
    van Schaijk, Frank G.
    van der Klis, Fiona R.
    Berbers, Guy A. M.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 335 (1-2) : 79 - 89
  • [2] Simultaneous determination of biomarkers in human sera by multiplex immunoassay
    Karlikova, M.
    Topolcan, O.
    TUMOR BIOLOGY, 2006, 27 : 95 - 95
  • [3] Development and validation of a multiplex fluorescent microsphere immunoassay assay for detection of porcine cytokines
    Hall, S. A.
    Ison, S. H.
    Owles, C.
    Coe, J.
    Sandercock, D. A.
    Zanella, A. J.
    METHODSX, 2019, 6 : 1218 - 1227
  • [4] Quantitative determination of human serum gelsolin:: Development and validation of an automated turbidimetric immunoassay
    Christensen, PH
    Gronkjær, K
    CLINICA CHIMICA ACTA, 2005, 355 : S221 - S221
  • [5] Development and validation of a one-step immunoassay for determination of cadmium in human serum
    Darwish, IA
    Blake, DA
    ANALYTICAL CHEMISTRY, 2002, 74 (01) : 52 - 58
  • [6] A multiplex microarray lateral flow immunoassay device for simultaneous determination of five mycotoxins in rice
    Saowalak Adunphatcharaphon
    Oluwatobi Kolawole
    Thanasat Sooksimuang
    Waraporn Panchan
    Wannee Wasuthep
    Anuwut Petdum
    Grit Pichayawaytin
    Rungroj Jintamethasawat
    Narusorn Doljirapisit
    Armote Somboonkaew
    Prae Noppakuadrittidej
    Sudtida Kaew-amdee
    Manlika Makornwattana
    Julie Meneely
    Christopher T. Elliott
    Awanwee Petchkongkaew
    Nitsara Karoonuthaisiri
    npj Science of Food, 8 (1)
  • [7] Development and validation of a novel multiplex immunoassay for the simultaneous quantification of food allergen proteins
    Hindley, James
    Filep, Stephanie
    Reid-Black, Kristina
    Lee, Jessica
    Murphy, Brian
    Block, Denise
    Oliver, Maria
    Kuklinska-Pijanka, Anna
    Bermingham, Max
    Chapman, Martin
    CLINICAL AND EXPERIMENTAL ALLERGY, 2019, 49 (12): : 1651 - 1651
  • [8] Development and validation of a novel multiplex immunoassay for the simultaneous quantification of food allergen proteins
    Oliver, M.
    Kuklinska-Pijanka, A.
    Bermingham, M.
    Chapman, M.
    Hindley, J.
    ALLERGY, 2017, 72 : 333 - 333
  • [9] Development and validation of a microfluidic multiplex immunoassay for the determination of levels and avidity of serum antibodies to tetanus, diphtheria and pertussis antigens
    Thomas, Debby
    Dillaerts, Doreen
    Cockx, Maaike
    Ampofo, Louanne
    She, Joseph
    Desombere, Isabelle
    Geukens, Nick
    Bossuyt, Xavier
    JOURNAL OF IMMUNOLOGICAL METHODS, 2022, 503
  • [10] Development of a quantitative multiplex immunoassay panel for the simultaneous detection of 32 cytokines/chemokines in mouse sample
    Chen, Yao
    Dong, Jiaxin
    Droll, Deborah
    Grisby, Michelle
    Mistry, Jehangir
    Ji, Shaoquan
    CLINICAL IMMUNOLOGY, 2008, 127 : S60 - S60