Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor

被引:74
|
作者
Feldmann, Andri [1 ]
Schmitz, Roger [2 ]
Erlacher, Daniel [1 ]
机构
[1] Univ Bern, Inst Sport Sci, Bern, Switzerland
[2] Fortiori Design LLC, Hutchinson, KS USA
关键词
muscle oxygen saturation; oxygenation; oximetry; physiological calibration; FEMORAL BLOOD-GASES; NIRS; EXERCISE; REPRODUCIBILITY; DEOXYGENATION; VALIDATION; OXIMETRY; TISSUES; HEALTH;
D O I
10.1117/1.JBO.24.11.115001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Near-infrared spectroscopy (NIRS) to monitor muscle oxygen saturation (SmO2) is rapidly expanding into applied sports settings. However, the technology is limited due to its inability to convey quantifiable values. A test battery to assess reliability and validity of a 0% to 100% scale modeled by a commercially available NIRS device was established. This test battery applies a commonly used technique, the arterial occlusion method (AOM) to assess repeatability, reproducibility, and face validity. A total of 22 participants completed the test battery to scrutinize the 0% to 100% scale provided by the device. All participants underwent repeated AOM tests in passive and active conditions. The SmO2 minimum and SmO2 maximum values were obtained from the AOM and were used in the subsequent analysis. Repeatability and reproducibility were tested for equivalency and Bland-Altman plots were generated. Face validity was assessed by testing SmO2 values against an a priori defined threshold for mixed venous blood during AOM response. The device exhibits an appropriately functional 0% to 100% scale that is reliable in terms of repeatability and reproducibility. Under the conditions applied in the test battery design, the device is considered valid for application in sports. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Near-infrared spectroscopy-derived tissue oxygen saturation in battlefield injuries: A case series report
    Beilman G.J.
    Blondet J.J.
    [J]. World Journal of Emergency Surgery, 4 (1)
  • [2] The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults
    de Oliveira, Gustavo Vieira
    Volino-Souza, Monica
    Barros-Santos, Elisa
    Conte-Junior, Carlos Adam
    Alvares, Thiago Silveira
    [J]. SPORT SCIENCES FOR HEALTH, 2022, 18 (04) : 1221 - 1228
  • [3] Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise
    Austin, KG
    Daigle, KA
    Patterson, P
    Cowman, J
    Chelland, S
    Haymes, EM
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2005, 76 (04) : 440 - 449
  • [4] The influence of cardiovascular risk factors on near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery in older adults
    Gustavo Vieira de Oliveira
    Mônica Volino-Souza
    Elisa Barros-Santos
    Carlos Adam Conte-Junior
    Thiago Silveira Alvares
    [J]. Sport Sciences for Health, 2022, 18 : 1221 - 1228
  • [5] Physiologic Determinants of Near-Infrared Spectroscopy-Derived Cerebral and Tissue Oxygen Saturation Measurements in Critically Ill Patients
    Cody, Neil
    Bradbury, Ian
    McMullan, Ross R.
    Quinn, Gerard
    O'Neill, Aisling
    Ward, Kathryn
    McCann, Justine
    McAuley, Daniel F.
    Silversides, Jonathan A.
    [J]. CRITICAL CARE EXPLORATIONS, 2024, 6 (05)
  • [6] Near-infrared spectroscopy-derived muscle oxygen saturation during exercise recovery and flow-mediated dilation are impaired in HIV-infected patients
    Volino-Souza, Monica
    de Oliveira, Gustavo Vieira
    Barros-Santos, Elisa
    Pinheiro, Vivian
    Machado-Santos, Ana Paula
    Conte-Junior, Carlos A.
    Alvares, Thiago Silveira
    [J]. MICROVASCULAR RESEARCH, 2020, 130
  • [7] Effects of Different Hemoglobin Levels on Near-Infrared Spectroscopy-Derived Cerebral Oxygen Saturation in Elderly Patients Undergoing Noncardiac Surgery
    Delis, Achilles
    Bautz, Derek
    Ehrentraut, Heidi
    Doll, Karin
    Randau, Thomas M.
    Strauss, Andreas C.
    Habicht, Ivana
    Gueresir, Erdem
    Bogatsch, Holger
    Kranke, Peter
    Wittmann, Maria
    Meybohm, Patrick
    Velten, Markus
    [J]. TRANSFUSION MEDICINE AND HEMOTHERAPY, 2023, 50 (04) : 270 - 276
  • [8] Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise
    Tew, Garry A.
    Ruddock, Alan D.
    Saxton, John M.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 110 (05) : 1083 - 1089
  • [9] Near infrared spectroscopy-derived interstitial hydrogen ion concentration and tissue oxygen saturation during ambulation
    Stuart M. C. Lee
    Mark S. F. Clarke
    Daniel P. O’Connor
    Leah Stroud
    Gwenn E. C. Ellerby
    Babs R. Soller
    [J]. European Journal of Applied Physiology, 2011, 111 : 1705 - 1714
  • [10] Near infrared spectroscopy-derived interstitial hydrogen ion concentration and tissue oxygen saturation during ambulation
    Lee, Stuart M. C.
    Clarke, Mark S. F.
    O'Connor, Daniel P.
    Stroud, Leah
    Ellerby, Gwenn E. C.
    Soller, Babs R.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (08) : 1705 - 1714