Post-fire behavior of unconfined and steel tube confined rubberized concrete under axial compression

被引:36
|
作者
Bengar, Habib Akbarzadeh [1 ]
Shahmansouri, Amir Ali [1 ]
机构
[1] Univ Mazandaran, Dept Civil Engn, Babolsar, Iran
关键词
Steel-tube confined concrete; Axial compressive behavior; Tire rubber aggregate; Elevated temperatures; STUB COLUMNS; FIRE RESISTANCE; ELEVATED-TEMPERATURES; MECHANICAL-PROPERTIES; STRENGTH; PERFORMANCE; AGGREGATE; FIBER; UHPC; POLYPROPYLENE;
D O I
10.1016/j.istruc.2021.03.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Employing steel as a confining material for concrete has gradually been gaining popularity over the last decades. The literature demonstrates strength improvement, concrete stiffness, damage reduction, and delayed failure of steel-confined concrete after exposure to fire. Concrete columns confined by steel tubes, referred to as the steel tube-confined concrete (STCC) columns, have enhanced performance in terms of axial loading. Moreover, the presence of tire rubber aggregate in concrete mix has been shown to improve the plasticity and energy absorption, particularly in seismic areas. Even so, this method may decrease concrete strength in case of exposure to fire. In the present work, the compressive behavior of rubberized concretes confined by steel tubes was investigated where the replacement percentages of fine aggregates with rubber were 0, 7.5, and 15%. Thirty specimens were tested mechanically after thermal loading at 200, 400, 600, and 800 degrees C. The post-fire physicomechanical properties involving the failure modes, compressive stress-strain relationships, compressive strengths, elastic moduli, stiffness, and peak strain were experimentally investigated, together with visual observations. The experimental results demonstrate that an increase in the exposed temperature up to 400 degrees C does not have a significant effect on the compressive strength of rubberized STCC, whilst an increased temperature to 800 degrees C results in a significant decrease in the compression of the specimens. It is also indicated increasing the exposure temperature and crumb rubber replacement ratio leads to lead to an increase in the strain at peak stress of steel tube confined rubberized concrete.
引用
收藏
页码:731 / 745
页数:15
相关论文
共 50 条
  • [1] Cyclic Behavior of Actively Confined Rubberized Concrete Under Axial Compression
    Gholampour, A.
    Pour, A. Fallah
    Hassanli, R.
    Ozbakkaloglu, T.
    PROCEEDINGS OF THE 25TH AUSTRALASIAN CONFERENCE ON MECHANICS OF STRUCTURES AND MATERIALS (ACMSM25), 2020, 37 : 287 - 293
  • [2] Behavior of Actively Confined Rubberized Concrete under Cyclic Axial Compression
    Gholampour, Aliakbar
    Pour, Ali Fallah
    Hassanli, Reza
    Ozbakkaloglu, Togay
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (11)
  • [3] Post-fire residual behavior of square steel tube confined steel-reinforced concrete slender columns under axial compression: Tests, numerical simulation, and calculation methods
    Peng, Kang
    Yang, Hua
    Liu, Faqi
    Wang, Fengqin
    ENGINEERING STRUCTURES, 2025, 333
  • [4] Post-Fire Exposure Behavior of Circular Concrete-filled Steel Tube Column under Axial Loading
    Tiwary, Aditya Kumar
    Gupta, Ashok Kumar
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (01) : 52 - 65
  • [5] Post-Fire Exposure Behavior of Circular Concrete-filled Steel Tube Column under Axial Loading
    Aditya Kumar Tiwary
    Ashok Kumar Gupta
    International Journal of Steel Structures, 2021, 21 : 52 - 65
  • [6] Behavior and Strength Predictions for CFRP Confined Rubberized Concrete under Axial Compression
    Tufail, Rana Faisal
    Feng, Xiong
    Farooq, Danish
    Abdelmelek, Nabil
    Lubloy, Eva
    Maqsoom, Ahsen
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (01): : 164 - 178
  • [7] Fire and post-fire performance of circular steel tube confined reinforced concrete columns
    Liu, F.
    Yang, H.
    Zhang, S.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 787 - 793
  • [8] Axial compressive behavior of square steel tube confined rubberized concrete stub columns
    Yang Zhaoyuan
    Qiao Qiyun
    Cao Wanlin
    Gao Xiaopeng
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [9] Behavior of unconfined and CFRP confined rubberized concrete
    Tufail, Rana Faisal
    Feng, Xiong
    Zahid, Muhammad
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2020, 15 (01) : 65 - 83
  • [10] Study on axial compressive behavior of circular steel tube confined rubberized concrete stub columns
    Zhaoyuan, Yang
    Qiyun, Qiao
    Wanlin, Cao
    Jiafeng, Li
    STRUCTURES, 2022, 41 : 887 - 907