Rapid, accurate and non-invasive detection of cerebrospinal fluid leakage using combined determination of β-trace protein in secretion and serum

被引:56
|
作者
Risch, L
Lisec, I
Markus, JD
Podvinecb, M
Landolt, H
Huber, AR [1 ]
机构
[1] Kantonsspital, Dept Lab Med, CH-5001 Aarau, Switzerland
[2] Acad Teaching Hosp, VIVIT, Clin Decis Making Res Unit, Feldkirch, Austria
[3] Kantonsspital, Dept Otorhinolaryngol, CH-5001 Aarau, Switzerland
[4] Kantonsspital, Dept Neurosurg, CH-5001 Aarau, Switzerland
关键词
beta-trace; cerebrospinal fluid leak; glomerular filtration rate; prostaglandin D synthase; reference values; sensitivity and specificity;
D O I
10.1016/j.cccn.2004.09.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: p-Trace protein (Btp) has been proposed as a valuable marker of cerebrospinal fluid (CSF) leakage overcoming the drawbacks of beta-2-transferrin (B-2Tr) determination. However, there is still controversy about the appropriate cut-offs to be used (range 0.35-6 mg/L). The aim of the study was to evaluate cut-offs of Btp determination for detection CSF leakage. Further, we assessed whether the Btp secretion to serum ratio (Btp-sec/ser-ratio) would add diagnostic value. Methods: Prospective study in patients with suspected CSF leakage. Quantitative determination of Btp in secretion and serum (Dade-Behring) and qualitative measurement of B-2-Tr in secretion and serum. Results were assessed in view of clinical data. Cut-offs and diagnostic characteristics were determined by ROC analysis. Results: A total of 176 samples, were assessed originating from 105 patients. In 43 samples CSF leakage could be confirmed. Sensitivity of B-2-Tr was 84% specificity amounted to 100%. The area under the curve (AUC) for Btp-measurement in secretion was 0.98. At a cut-off of 0.68 mg/L, sensitivity was 100% and specificity 91%. At a cut-off of 1.11 mg/L, the specificity was 100% with a sensitivity of 93%. The Btp-sec/ser-ratio has an AUC of 0.99. Combining a 0.68 mg/L cut-off in secretion with a Btp-sec/ser-ratio cut-off of 4.9 reveals a sensitivity of 99% and a specificity of 100%. Conclusions: Btp is a rapid and accurate marker for the presence of CSF leakage. Combining measurement of Btp in secretion together with determination of the Btp-sec/ser-ratio enhances the diagnostic characteristics of the Btp assay. Determination of Btp in both serum and secretion is thus recommended. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [1] β-TRACE PROTEIN AS A MARKER FOR DETECTION CEREBROSPINAL FLUID LEAKAGE
    Stosic, G.
    Obradovic, I.
    Vujotic, L. J.
    Bogosavljevic, V.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S628 - S628
  • [2] Cerebrospinal fluid leakage and headache after lumbar puncture: a prospective non-invasive imaging study
    Wang, Yen-Feng
    Fuh, Jong-Ling
    Lirng, Jiing-Feng
    Chen, Shih-Pin
    Hseu, Shu-Shya
    Wu, Jaw-Ching
    Wang, Shuu-Jiun
    BRAIN, 2015, 138 : 1492 - 1498
  • [3] Circulating microRNAs combined with PSA for accurate and non-invasive prostate cancer detection
    Mello-Grand, Maurizia
    Gregnanin, Ilaria
    Sacchetto, Lidia
    Ostano, Paola
    Zitella, Andrea
    Bottoni, Giulia
    Oderda, Marco
    Marra, Giancarlo
    Munegato, Stefania
    Pardini, Barbara
    Naccarati, Alessio
    Gasparini, Mauro
    Gontero, Paolo
    Chiorino, Giovanna
    CARCINOGENESIS, 2019, 40 (02) : 246 - 253
  • [4] Rapid and non-invasive detection of cystic echinococcosis in sheep based on serum fluorescence spectrum combined with machine learning algorithms
    Xu, Shengke
    Dawuti, Wubulitalifu
    Maimaitiaili, Maierhaba
    Dou, Jingrui
    Aizezi, Malike
    Aimulajiang, Kalibixiati
    Lu, Xiaoyi
    Lu, Guodong
    JOURNAL OF BIOPHOTONICS, 2024, 17 (04)
  • [5] DETECTION OF COLORECTAL POLYP USING NON-INVASIVE SERUM MIRNA BIOMARKERS
    Sin, Ryan Wai-Yan
    Foo, Dominic Chi-Chung
    Law, Wai-Lun
    Ng, Lui
    GUT, 2022, 71 : A66 - A66
  • [6] Cerebrospinal fluid leakage:: Agarose gel electrophoresis detection of β2-transferrin and nephelometric quantification of β-trace protein
    Sanders, EL
    Clark, RJ
    Katzmann, JA
    CLINICAL CHEMISTRY, 2004, 50 (12) : 2401 - 2403
  • [7] Serum Exosomal Protein Profiling for the Non-invasive Detection of Cardiac Allograft Rejection
    Kennel, Peter J.
    Maldonado, Dawn
    Givens, Raymond
    Brunjes, Danielle
    Castillero, Estibaliz
    Chen, Emily
    George, Isaac
    Mancini, Donna
    Schulze, P. Christian
    CIRCULATION, 2015, 132
  • [8] Serum exosomal protein profiling for the non-invasive detection of cardiac allograft rejection
    Kennel, Peter J.
    Saha, Amit
    Maldonado, Dawn A.
    Givens, Raymond
    Brunjes, Danielle L.
    Castillero, Estibaliz
    Zhang, Xiaokan
    Ji, Ruiping
    Yahi, Alexandre
    George, Isaac
    Mancini, Donna M.
    Koller, Antonius
    Fine, Barry
    Zorn, Emmanuel
    Colombo, Paolo C.
    Tatonetti, Nicholas
    Chen, Emily I.
    Schulze, P. Christian
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (03): : 409 - 417
  • [9] Determination of residual moisture in lyophilized protein pharmaceuticals using a rapid and non-invasive method: Near infrared spectroscopy
    Lin, TP
    Hsu, CC
    PDA JOURNAL OF PHARMACEUTICAL SCIENCE AND TECHNOLOGY, 2002, 56 (04) : 196 - 205
  • [10] Rapid and non-invasive detection of plants senescence using a delayed fluorescence technique
    Zhang, Lingrui
    Xing, Da
    Wang, Junsheng
    Li, Lingling
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2007, 6 (06) : 635 - 641