Preoperative renal volumes as a predictor of graft function in living donor transplantation

被引:73
|
作者
Saxena, AB
Busque, S
Arjane, P
Myers, BD
Tan, JC
机构
[1] Stanford Univ, Adult Kidney & Pancreas Transplant Program, Med Ctr, Dept Surg, Palo Alto, CA 95025 USA
[2] Stanford Univ, Div Nephrol, Med Ctr, Palo Alto, CA 95025 USA
[3] Univ Montreal, Dept Urol, Montreal, PQ H3C 3J7, Canada
关键词
renal function; living donor; magnetic resonance imaging (MRI); renal volume; graft function;
D O I
10.1053/j.ajkd.2004.07.012
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Nephron underdosing and donor kidney-recipient body size mismatch can lead to poor allograft function. The purpose of this study is to examine the relationship between donor kidney volume and posttransplantation graft function by using magnetic resonance imaging (MRI) to obtain renal volumes. Previous investigators used donor body surface area as a surrogate for kidney size or measured renal volume by using ultrasonography; both these techniques are inaccurate measures of renal volume. Intraoperative weights are more accurate, but provide information only after the transplantation is underway. More recently, MRI has been used preoperatively to screen living donors; these novel MRI techniques also provide information regarding renal size. Methods: We performed a retrospective analysis of 54 patients who underwent living donor transplantation at our institution from 2000 to 2002. All living donors underwent preoperative renovascular imaging using MRI, and renal volumes were obtained for each donor. A transplant kidney volume-recipient body weight (Vol/Wt) ratio was determined for each donor-recipient pair, and patients were divided into tertiles corresponding to 3 groups: high (>2.7), medium (2 to 2.7), and low (<2) "nephron dose" ratios. Results: Glomerular filtration rate (GFR) correlated with Vol/Wt ratio at 6 and 12 months (r = 0.46; P = 0.0005 and r = 0.41; P = 0.003). At 6 months, mean GFRs in the low, medium, and high groups were 52.4 +/- 2.8 (SEM), 64.5 +/- 6.2, and 82.0 +/- 4.4 mL/min, respectively (P < 0.0005). At 12 months, GFRs in the low, medium, and high groups were 51.6 +/- 3.6, 63.3 +/- 3.8, and 83.9 +/- 5.4 mL/min, respectively (P < 0.0001). Conclusion: Transplantation of donor-recipient pairs with a Vol/Wt ratio less than 2 cm(3)/kg was associated with significantly worse graft function. Donor kidney volumes measured by means of preoperative MRI can be used to calculate Vol/Wt ratios before transplantation and identify patients at risk for a low GFR posttransplantation.
引用
收藏
页码:877 / 885
页数:9
相关论文
共 50 条
  • [1] Donor renal cortical volumes and 6-month graft function in living donor transplantation.
    Yan, J
    Busque, S
    Myers, BD
    Tan, JC
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 : 262 - 262
  • [2] Pre-operative MRI kidney volumes as a predictor of graft function in living donor kidney transplantation.
    Bhatt, A
    Arjane, P
    Busque, S
    Tan, JC
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 11A - 11A
  • [3] Donor Kidney Morphomics Impact on Graft Function in Living Donor Renal Transplantation
    Barnhart, Kara
    Roberts, Jonathan
    Tishberg, Lindsay
    Dahbour, Layth
    Terjimanian, Michael
    Waits, Seth
    Englesbe, Michael
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 : 68 - 68
  • [4] Renal Measurements on CT Angiograms: Correlation with Graft Function at Living Donor Renal Transplantation
    Yano, Motoyo
    Lin, Michael F.
    Hoffman, Kelsey A.
    Vijayan, Anitha
    Pilgram, Thomas K.
    Narra, Vamsi R.
    [J]. RADIOLOGY, 2012, 265 (01) : 151 - 157
  • [5] The Impact of Living Donor Nephrectomy With Multiple Renal Arteries on Graft Function and Complications in Renal Transplantation
    Kasap, Yusuf
    Karaaslan, Mustafa
    Senel, Samet
    Tastemur, Sedat
    Olcucuoglu, Erkan
    [J]. TRANSPLANTATION PROCEEDINGS, 2021, 53 (06) : 1887 - 1891
  • [6] Fragility Index, a Novel Predictor of Renal Function after Living Donor Liver Transplantation
    Kuramitsu, K.
    Fukumoto, T.
    Fukushima, K.
    Iwasaki, T.
    Tominaga, M.
    Ku, Y.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 438 - 438
  • [7] Evaluating graft function in pediatric recipients for living donor renal transplantation: Is laparoscopic donor nephrectomy safe?
    Mishra, Shashikant
    Ganpule, Arvind
    Muthu, V.
    Sabnis, Ravindra B.
    Desai, Mahesh R.
    [J]. INDIAN JOURNAL OF UROLOGY, 2009, 25 (02) : 195 - 198
  • [8] Delayed graft function in living donor kidney transplantation
    Khan, Taqi
    Kamal, Suhaib
    Koshaji, Basem
    Akhtar, Faheem
    [J]. ANNALS OF TRANSPLANTATION, 2013, 18 : 434 - 435
  • [9] THE EFFECT OF MANNITOL IN LIVING DONOR RENAL GRAFT FUNCTION
    Soliman, Amin
    Khashab, Sahier
    Seif, Nazmy
    Elbaz, Basma
    Elkholy, Manar
    [J]. TRANSPLANT INTERNATIONAL, 2017, 30 : 293 - 294
  • [10] Reliable Estimation of Preoperative Graft Volume in Living Donor Liver Transplantation
    Latif, Amer
    Dilshad, M. Akif
    Naz, Sumbul
    Jabbar, Sadia
    Naseer, Faisal
    Amir, Usama
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (11): : 3030 - 3033