ULTRASOUND-GUIDED CENTRAL VENOUS ACCESS USING GOOGLE GLASS

被引:39
|
作者
Wu, Teresa S. [1 ,2 ]
Dameff, Christian J. [1 ,2 ]
Tully, Jeffrey L. [1 ,3 ]
机构
[1] Univ Arizona, Coll Med Phoenix, Phoenix, AZ 85014 USA
[2] Maricopa Cty Gen Hosp, Dept Emergency Med, Phoenix, AZ USA
[3] Phoenix Childrens Hosp, Phoenix, AZ USA
来源
JOURNAL OF EMERGENCY MEDICINE | 2014年 / 47卷 / 06期
关键词
Google Glass; simulation; medical education; wearable technology; ultrasound;
D O I
10.1016/j.jemermed.2014.07.045
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Objective: Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Methods: Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. Results: All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p <= 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p <= 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). Conclusions: In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. (C) 2014 Elsevier Inc.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [1] Ultrasound-guided central venous access - Discussion
    Battistella, FD
    Liu, K
    Richardson, JD
    Fry
    [J]. ARCHIVES OF SURGERY, 1999, 134 (07) : 741 - 741
  • [2] Future directions for ultrasound-guided central venous access
    O'Leary, Ronan
    Bodenham, Andrew
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (05) : 327 - 328
  • [3] Ultrasound-guided central venous access in infants and children
    Machata, Anette-Marie
    Marhofer, Peter
    Breschan, Christian
    [J]. TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2013, 3 (04) : 188 - 192
  • [4] Ultrasound-guided central venous access in patients with uncorrected coagulopathy
    Reusz Geza
    Langer Csilla
    Hevessy Tibor
    Csomos Akos
    [J]. ORVOSI HETILAP, 2015, 156 (27) : 1085 - 1090
  • [5] Ultrasound-guided central venous access: what’s new?
    Gregory A. Schmidt
    Julien Maizel
    Michel Slama
    [J]. Intensive Care Medicine, 2015, 41 : 705 - 707
  • [6] Asepsis in Ultrasound-Guided Central Venous Access: A New Technique
    Subhan, I
    Jain, A.
    Joshi, M.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2009, 54 (03) : S100 - S100
  • [7] Ultrasound-guided central venous access: a homemade phantom for simulation
    Kendall, John L.
    Faragher, Jeffrey P.
    [J]. CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2007, 9 (05) : 371 - 373
  • [8] Ultrasound-guided central venous access: what's new?
    Schmidt, Gregory A.
    Maizel, Julien
    Slama, Michel
    [J]. INTENSIVE CARE MEDICINE, 2015, 41 (04) : 705 - 707
  • [9] An Educational Intervention to Improve Ultrasound Competency in Ultrasound-Guided Central Venous Access
    Werner, Heidi C.
    Vieira, Rebecca L.
    Rempell, Rachel G.
    Levy, Jason A.
    [J]. PEDIATRIC EMERGENCY CARE, 2016, 32 (01) : 1 - 5
  • [10] Ultrasound-guided peripheral venous access
    Fuzier, Regis
    Rouge, Pierre
    Pierre, Sebastien
    [J]. PRESSE MEDICALE, 2016, 45 (02): : 177 - 182