Calibration of neutron linear position sensitive detector

被引:1
|
作者
Mergia, K [1 ]
Salevris, A [1 ]
Messoloras, S [1 ]
机构
[1] NCSR Demokritos, Inst Nucl Technol & Radiat Protect, Aghia Paraskevi 15310, Greece
来源
关键词
PACS: 07.05.Hd; 29.40.Gx;
D O I
10.1007/s003390201928
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method to transform the detector channels to scattering angles based on both measurements and a theoretical development which corrects for electronic imperfections is presented. The overlay of the same Bragg peak measured from different detectors and/or different angles even at the tails of the peak is better than a few minutes of arc - much better than the overall resolution of the instrument.
引用
收藏
页码:S145 / S147
页数:3
相关论文
共 50 条
  • [1] Calibration of neutron linear position sensitive detector
    K. Mergia
    A. Salevris
    S. Messoloras
    [J]. Applied Physics A, 2002, 74 : s145 - s147
  • [2] LINEAR MULTIANODE POSITION-SENSITIVE NEUTRON DETECTOR
    PATRA, AK
    CHINCHANIKAR, SR
    JOSHI, JN
    DANDE, YD
    UDYAVAR, RS
    DESAI, SS
    KOTHARE, RS
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1993, 31 (06) : 418 - 420
  • [3] DEVELOPMENT OF A LINEAR POSITION-SENSITIVE NEUTRON DETECTOR
    SCHELTEN, J
    KURZ, R
    NADAY, I
    SCHAFER, W
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2): : 319 - 330
  • [4] A NEUTRON DIFFRACTOMETER WITH A LINEAR POSITION-SENSITIVE DETECTOR
    PARANJPE, SK
    DANDE, YD
    [J]. PRAMANA, 1989, 32 (06) : 793 - 800
  • [5] A POSITION SENSITIVE NEUTRON DETECTOR
    BERKOWITZ, EH
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1969, 73 (02): : 225 - +
  • [6] EVALUATION OF A LINEAR POSITION-SENSITIVE NEUTRON DETECTOR FOR POWDER SPECTROSCOPY
    CHANG, IP
    NUNES, AC
    [J]. AIP CONFERENCE PROCEEDINGS, 1982, (89) : 199 - 201
  • [7] NEUTRON POWDER DIFFRACTOMETER EMPLOYING A LINEAR POSITION-SENSITIVE DETECTOR
    NUNES, AC
    CHANG, IP
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (02): : 96 - 96
  • [8] Position-sensitive neutron detector
    Kuznetsov, AV
    Vakhtin, DN
    Radivojevich, Z
    Alkhazov, ID
    Lyapin, VG
    Trzaska, WH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 372 - 377
  • [9] A NEW LINEAR POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRON POWDER DIFFRACTOMETRY
    SCHAFER, W
    JANSEN, E
    ELF, F
    WILL, G
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (JUN) : 159 - 166
  • [10] A LARGE POSITION-SENSITIVE NEUTRON DETECTOR
    NETTER, P
    LASSEN, L
    SCHRECK, R
    GEMMEKE, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 165 - 174