Energy-saving Analysis of Reversible Ventilation System

被引:0
|
作者
Yong, Ren [1 ,2 ]
Zhen-ying, Mu [3 ]
Hong-tao, Zheng [1 ]
Shi, Chen [2 ]
Li-jun, Peng [2 ]
机构
[1] Harbin Engn Univ, Coll Power & Energy Engn, 145 Nantong St, Harbin, Peoples R China
[2] CCS Mans, Beijing, Peoples R China
[3] Beijing Gas Grp Co LTD, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
IAQ; reversible ventilation; effective fresh air ratio; energy-saving analysis;
D O I
10.4028/www.scientific.net/AMM.525.625
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new IAQ improved ventilation system-reversible ventilation system was designed. This system's working principle was introduced. For analyzing the superiority of reversible ventilation system, the conceptions of effective fresh air ratio and minimum effective fresh air ratio were described. The formula of effective fresh air ratio was deduced. The formula can be used to analyze the different air outputs of reversible ventilation system and conventional general ventilation system, in rooms with the same degree of fresh air. It can be taken as the guide for design and actual applications of reversible ventilation system.
引用
收藏
页码:625 / +
页数:2
相关论文
共 50 条
  • [1] Energy-saving mine ventilation
    B. P. Kazakov
    A. V. Shalimov
    A. S. Kiryakov
    [J]. Journal of Mining Science, 2013, 49 : 475 - 481
  • [2] Energy-saving mine ventilation
    Kazakov, B. P.
    Shalimov, A. V.
    Kiryakov, A. S.
    [J]. JOURNAL OF MINING SCIENCE, 2013, 49 (03) : 475 - 481
  • [3] ANALYSIS OF ENERGY-SAVING POTENTIAL OF VENTILATION IN TRANSITIONAL SEASONS
    Wang, Lihui
    Huang, Chen
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 803 - 810
  • [4] System for hazard monitoring and energy-saving control of ventilation process
    Mironowicz, W
    Wasilewski, S
    [J]. ICS-MRI '97: PROCEEDINGS OF THE 27TH INTERNATIONAL CONFERENCE OF SAFETY IN MINES RESEARCH INSTITUTES - SELECT PAPERS, 1997, : 157 - 169
  • [5] Analysis of the Energy-Saving Building Evaluation System
    Li, Xiao-Juan
    [J]. Journal of Taiwan Agricultural Engineering, 2022, 68 (02): : 74 - 80
  • [6] Research on Energy-saving of Adjustable Ventilation Platform Doors System in subway
    Zhang, Yue
    Li, Xiaofeng
    Wang, Bin
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 2058 - 2061
  • [7] Energy-saving Performance Analysis of Distributional Building Energy System
    Cao Yanfeng
    Li Hongqiang
    Dong Wenjing
    Tang Zhihua
    Zhang Guoqiang
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [8] Energy-saving ventilation system for sheep premises to ensure food security and safety
    Issakhanov, Muratbek
    Alibek, Nessipbek
    Dyusenbayev, Turemurat
    Taldybayeva, Aigul
    [J]. FOOD SCIENCE AND TECHNOLOGY, 2022, 42
  • [9] Energy-saving potential of a novel ventilation system with decentralised fans in an office building
    Gunner, Amalie
    Hultmark, Goran
    Vorre, Anders
    Afshari, Alireza
    Bergsoe, Niels Christian
    [J]. ENERGY AND BUILDINGS, 2014, 84 : 360 - 366
  • [10] Energy-saving automated system for microclimate in agricultural premises with utilization of ventilation air
    Tikhomirov, Dmitry
    Vasilyev, Alexey N.
    Budnikov, Dmitry
    Vasilyev, Alexey A.
    [J]. WIRELESS NETWORKS, 2020, 26 (07) : 4921 - 4928