Measurement of soluble transferrin receptor by immunoturbidimetry and immunonephelometry

被引:20
|
作者
Cotton, F [1 ]
Thiry, P [1 ]
Boeynaems, JM [1 ]
机构
[1] Free Univ Brussels, Hop Erasme, Dept Clin Chem, B-1070 Brussels, Belgium
关键词
soluble transferrin receptor (sTfR); immunonephelometry; immunoturbidimetry; method comparison;
D O I
10.1016/S0009-9120(00)00071-0
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: To evaluate and compare two new commercially available immunoturbidimetric and immunonephelometric assays for measuring soluble transferrin receptor (sTfR) in serum. To adapt the immunonephelometric assay to an automated chemistry analyzer. Design and methods: Total imprecisions and detection limits were calculated and compared. Fifty-six samples were used for methods comparison. The nephelometric assay was adapted to the Hitachi 911 analyzer. Results: Both methods displayed acceptable imprecisions and detection limits. Their correlation was good but a proportional bias was observed. The adaptation of the nephelometric assay to the Hitachi 911 was successful. Conclusions: These two new immunoassays are analytically acceptable and more practicable than previously developed methods. The differences observed between both methods underscores the need for standardization, The nephelometric assay was easily adaptable to an automated chemistry analyzer. Copyright (C) 2000 The Canadian Society of Clinical Chemists.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 50 条
  • [1] Albumin by immunonephelometry or immunoturbidimetry? That's the question
    Camara Hernandez, V.
    De Paula Ruiz, M.
    Torrado Carrion, R.
    Douhal, Y.
    Pascual Duran, T.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S469 - S469
  • [2] Evaluation of kits for measurement of the soluble transferrin receptor
    Åkesson, A
    Bjellerup, P
    Vahter, M
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1999, 59 (02): : 77 - 81
  • [3] Measurement of soluble transferrin receptor in serum of healthy adults
    Allen, J
    Backstrom, KR
    Cooper, JA
    Cooper, MC
    Detwiler, TC
    Essex, DW
    Fritz, RP
    Means, RT
    Meier, PB
    Pearlman, SR
    Roitman-Johnson, B
    Seligman, PA
    [J]. CLINICAL CHEMISTRY, 1998, 44 (01) : 35 - 39
  • [4] TRANSFERRIN REDUCES THE PRODUCTION OF SOLUBLE TRANSFERRIN RECEPTOR
    BAYNES, RD
    [J]. PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1995, 209 (03): : 286 - 294
  • [5] Soluble transferrin receptor-transferrin complex in serum: Measurement by latex agglutination nephelometric immunoassay
    Hikawa, A
    Nomata, Y
    Suzuki, T
    Ozasa, H
    Yamada, O
    [J]. CLINICA CHIMICA ACTA, 1996, 254 (02) : 159 - 172
  • [6] OVERESTIMATION OF IMMUNOGLOBULINS IN THE PRESENCE OF RHEUMATOID-FACTOR BY KINETIC IMMUNONEPHELOMETRY AND RAPID IMMUNOTURBIDIMETRY
    CHAMBERS, RE
    WHICHER, JT
    PERRY, DE
    MILFORDWARD, A
    WHITE, PAE
    FIFIELD, R
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 : 520 - 524
  • [7] Soluble transferrin receptor in complicated anemia
    Braga, Federica
    Infusino, Ilenia
    Dolci, Alberto
    Panteghini, Mauro
    [J]. CLINICA CHIMICA ACTA, 2014, 431 : 143 - 147
  • [8] Clinical use of soluble transferrin receptor
    Punnonen, K
    Suominen, P
    Kuusinen, A
    Kuiper-Kramer, E
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (04) : 377 - 377
  • [9] ORIGIN OF A SOLUBLE TRUNCATED TRANSFERRIN RECEPTOR
    AHN, JH
    JOHNSTONE, RM
    [J]. BLOOD, 1993, 81 (09) : 2442 - 2451
  • [10] Preanalytical phase of soluble receptor of transferrin
    Banfi, G.
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2007, 28 (01) : 88 - 89