Development of an optimized thermodynamic model for VVER-1200 reactor-based nuclear power plants using genetic algorithm

被引:8
|
作者
Khan, Abid Hossain [1 ]
Hossain, Shakhawat [2 ]
Hasan, Mehedi [3 ]
Islam, Md Shafiqul [4 ]
Rahman, Md Mizanur [5 ]
Kim, Jin-Hyuk [6 ,7 ]
机构
[1] Bangladesh Univ Engn & Technol, Inst Nucl Power Engn, Dhaka 1000, Bangladesh
[2] Jashore Univ Sci & Technol, Dept Ind & Prod Engn, Jessore 7408, Bangladesh
[3] Bangladesh Atom Energy Commiss, Chem Div, Atom Energy Ctr, GPO Box 164, Dhaka 1000, Bangladesh
[4] Univ Dhaka, Dept Nucl Engn, Dhaka 1000, Bangladesh
[5] Atom Energy Res Estab, Inst Energy Sci, GPO Box 3787, Dhaka 1000, Bangladesh
[6] Korea Inst Ind Technol, Carbon Neutral Technol R&D Dept, Cheonan 31056, South Korea
[7] Univ Sci & Techmol, Convergence Mfg Syst Engn, Daejeon 34113, South Korea
关键词
Genetic algorithm; Nuclear power plant; Optimization; Thermodynamic model; VVER-1200; PUBLIC PERCEPTION; CLIMATE-CHANGE; EFFICIENCY; RISK;
D O I
10.1016/j.aej.2022.02.052
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, an optimized thermodynamic model for the secondary coolant loop of a VVER-1200 reactor-based nuclear power plant is developed. The values of some of the thermophysical parameters such as coolant flow rate, coolant inlet and outlet temperatures from the steam generator and the turbines, etc. are obtained from the available literature. On the other hand, the unknown plant parameters such as feedwater heater pressures are predicted using a Genetic Algorithm-based optimization process. Three crossover rates, 0.5, 0.7 and 0.9, and three mutation rates, 0.01, 0.05 and 0.1, are considered. Results reveal that the value of the optimization process of the thermodynamic model is not significantly affected by the change in the crossover rate or mutation rate. The optimized model is compared with two theoretical models, a model available in the literature and experimental data. Results reveal that the predicted values of the optimized model are more accurate compared to the other available options. The optimized model also predicts that the maximum overall efficiency and the maximum output power of a plant situated in tropical region should be around 35.87% and 1152.16MW(e) respectively for 28 degrees C tertiary coolant temperature, down by 3.94% from the rated values in cold weather. However, the power output at 35 degrees C tertiary coolant temperature is calculated to be 1117.88 MWe, almost 6.69% lower than the rated value for VVER-1200. Thus, the efficiency of the plant is highly sensitive to the weather variation of a region. (C) 2022 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University.
引用
收藏
页码:9129 / 9148
页数:20
相关论文
共 50 条
  • [1] Application of Fuzzy Controllers for Power Control of the VVER-1200 Nuclear Reactor
    Pravosud, S. S.
    Maslakov, D. S.
    Yakubov, Ya. O.
    PHYSICS OF ATOMIC NUCLEI, 2024, 87 (10) : 1430 - 1439
  • [2] Environmental Consequences of Using Ammonia-Ethanolamine Water Chemistry in the Secondary Circuit of VVER-1200 Nuclear Power Plants
    Kritsky, V. G.
    Gavrilov, A. V.
    Prokhorov, N. A.
    Motkova, E. A.
    Pelageecheva, N. A.
    Shvaleva, M. S.
    Karpov, A. V.
    THERMAL ENGINEERING, 2025, 72 (01) : 78 - 84
  • [3] Multipoint Kinetics Model with Power Reactivity Effect for the Axial Offset Control in the VVER-1200 Nuclear Reactor in the Load-Following Mode
    S. S. Pravosud
    Ya. O. Yakubov
    V. A. Susakin
    Physics of Atomic Nuclei, 2024, 87 (11) : 1579 - 1590
  • [4] Improving the transient stability of VVER-1000 reactor-based nuclear power plant units
    Kazakov V.A.
    Zhudenkov V.V.
    Kazakov K.V.
    Povarov V.P.
    Vitkovskii I.L.
    Thermal Engineering, 1600, Izdatel'stvo Nauka (61): : 47 - 53
  • [5] Research and development of the manufacturing technology of the low-speed turbines welded rotors for high-capacity nuclear power HCNP plants (VVER-1200)
    Abrosin A.A.
    Khodakov V.D.
    Pevkin P.S.
    Nikitin V.B.
    Welding International, 2020, 34 (7-9) : 329 - 334
  • [6] Optimization of designing the core fuel loading pattern in a VVER-1000 nuclear power reactor using the genetic algorithm
    Karahroudi, M. Rafiei
    Shirazi, S. A. Mousavi
    Sepanloo, K.
    ANNALS OF NUCLEAR ENERGY, 2013, 57 : 142 - 150
  • [7] FROM VVER-210 TO VVER-2000 - EXPERIENCE IN THE DEVELOPMENT AND IMPROVEMENT OF REACTOR DESIGNS FOR NUCLEAR-POWER-PLANTS
    STEKOLNIKOV, VV
    FEDOROV, VG
    ATOMIC ENERGY, 1994, 76 (04) : 300 - 307
  • [8] Module layout optimization using a genetic algorithm in light water modular nuclear reactor power plants
    Wrigley, P. A.
    Wood, P.
    Stewart, P.
    Hall, R.
    Robertson, D.
    NUCLEAR ENGINEERING AND DESIGN, 2019, 341 : 100 - 111
  • [9] A MATHEMATICAL MODEL OF THE ELECTRICAL ENGINEERING COMPLEX FOR DRIVE OF MAIN CIRCULATION PUMPS OF NUCLEAR REACTOR VVER-1000 OF NUCLEAR POWER PLANTS
    Vasyliv, K. M.
    Mazurenko, L., I
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2019, (06) : 12 - 20
  • [10] Measures for Ensuring Reliable Operation of the Welded Joint Connecting the Reactor Coolant Circuit's Header to the Shell of a Steam Generator Used at a VVER-1000 Reactor-Based Nuclear Power Station
    Kharchenko S.A.
    Trunov N.B.
    Korotaev N.F.
    Lyakishev S.L.
    Thermal Engineering, 2011, 58 (03) : 208 - 214