Proper Testing of Protection Systems Ensures Against False Tripping and Unnecessary Outages

被引:0
|
作者
Peterson, Oliver [1 ]
Scharlach, Rogerio [2 ]
Bahazar, Cesar [3 ]
机构
[1] Commonwealth Edison Co, 1N423 Swift Rd, Lombard, IL 60148 USA
[2] Schweitzer Engn Labs Inc, San Ramon, CA 94583 USA
[3] Schweitzer Engn Labs Inc, Lake Zurich, IL 60047 USA
关键词
through-fault; testing and commissioning; transformer testing; management of protection; avoid misoperations; bus protection; transformer protection; current transformers; testing procedures;
D O I
10.1109/PAPCON.2009.5185429
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper discusses the role of three-phase primary injection testing as an important part of the substation commissioning process. Individually testing the components of a protective relay scheme is common practice. Many times, this testing is performed without looking at how the equipment under test interacts with all the other components of the protective relay scheme. Several relay misoperations can be avoided by executing an overall testing plan with all the interconnected components. Three-phase primary current injection tests can be easily performed during equipment commissioning and can detect mistakes that would otherwise only be detected when load is available. This paper describes the planning, execution, and analysis of results of three-phase primary injection tests.
引用
收藏
页码:70 / +
页数:2
相关论文
共 8 条
  • [1] Optimal Protection Strategy Against False Data Injection Attacks in Power Systems
    Liu, Xuan
    Li, Zhiyi
    Li, Zuyi
    IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (04) : 1802 - 1810
  • [2] Protection Against Graph-Based False Data Injection Attacks on Power Systems
    Morgenstern, Gal
    Kim, Jip
    Anderson, James
    Zussman, Gil
    Routtenberg, Tirza
    IEEE TRANSACTIONS ON CONTROL OF NETWORK SYSTEMS, 2024, 11 (04): : 1924 - 1936
  • [3] Multiple Testing and Protection Against a Type 1 (False Positive) Error Using the Bonferroni and Hochberg Corrections
    Andrade, Chittaranjan
    INDIAN JOURNAL OF PSYCHOLOGY MEDICINE, 2019, 41 (01): : 99 - 100
  • [4] The Methods of Testing and Possibility to Overcome the Protection against Sabotage of Analog Intrusion Alarm Systems
    Hanacek, Adam
    Sysel, Martin
    INTELLIGENT SYSTEMS IN CYBERNETICS AND AUTOMATION THEORY, VOL 2, 2015, 348 : 119 - 128
  • [5] INVIVO AND INVITRO TESTING OF GLOVES FOR PROTECTION AGAINST UV-CURABLE ACRYLATE RESIN SYSTEMS
    RIETSCHEL, RL
    HUGGINS, R
    LEVY, N
    PRUITT, PM
    CONTACT DERMATITIS, 1984, 11 (05) : 279 - 282
  • [6] INTERNATIONAL-COMMISSION FOR PROTECTION AGAINST ENVIRONMENTAL MUTAGENS AND CARCINOGENS - BACTERIAL SYSTEMS FOR CARCINOGENICITY TESTING
    MOHN, GR
    BIOLOGISCHES ZENTRALBLATT, 1983, 102 (01): : 79 - 95
  • [7] TOTAL: Optimal Protection Strategy Against Perfect and Imperfect False Data Injection Attacks on Power Grid CyberPhysical Systems
    Tian, Jiwei
    Wang, Buhong
    Li, Tengyao
    Shang, Fute
    Cao, Kunrui
    Guo, Rongxiao
    IEEE INTERNET OF THINGS JOURNAL, 2021, 8 (02) : 1001 - 1015
  • [8] In vivo testing of the protection of gloves against acrylates in dentin-bonding systems on patients with known contact allergy to acrylates
    Andersson, T
    Bruze, M
    Björkner, B
    CONTACT DERMATITIS, 1999, 41 (05) : 254 - 259