Field Comparison Study of Indoor Environment Quality in Office Buildings with Underfloor and Overhead Ventilation Systems

被引:0
|
作者
Ouazia, Boualem [1 ]
Tardif, Michel [2 ]
Thompson, Alexandra [1 ]
Booth, Daniel [1 ]
机构
[1] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
[2] Nat Resource Canada, Ottawa, ON, Canada
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of UFAD (Underfloor Air Distribution) systems is increasing rapidly and reported advantages of UFAD include energy savings and improved indoor air quality. At present few publications documenting measurements of ventilation effectiveness and indoor environment quality in occupied buildings with UFAD have been identified. In this field comparison study we measured several aspects of the thermal environment in two buildings with different ventilation systems (under-floor air distribution and mixing) located in Montreal (Quebec). The results are presented in terms of thermal stratification, predicted thermal comfort indices (VATD, limit to air speed and PMV/PPD), and IAQ index (CO2 level and stratification). The aim of the study was to determine whether UFAD in practice results in improved ventilation effectiveness compared to typical overhead air distribution without affecting the thermal comfort. The study found that there was little stratification for UFAD under operating conditions and it performed as a mixing system, thus no improvement in ventilation effectiveness was identified in the occupied zone, in comparison to the reference mixing system. In addition the predicted thermal comfort in terms of VATD, air speed and PMV/PPD was similar to those obtained for mixing ventilation and was within the acceptable limits set by ASHRAE 55-2010.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of underfloor and overhead air distribution systems in an office environment
    Ho, Son H.
    Rosario, Luis
    Rahman, Muhammad M.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (07) : 1415 - 1427
  • [2] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [3] INDOOR AIR-QUALITY AND HEALTH IN 2 OFFICE BUILDINGS WITH DIFFERENT VENTILATION SYSTEMS
    HEDGE, A
    STERLING, TD
    STERLING, EM
    COLLETT, CW
    STERLING, DA
    NIE, V
    [J]. ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 115 - 128
  • [4] Experimental study of thermal comfort in an office environment with an underfloor ventilation system
    Wan, MP
    Chao, CY
    [J]. INDOOR AND BUILT ENVIRONMENT, 2002, 11 (05) : 250 - 265
  • [5] Indoor environment quality and upgrading of European office buildings
    Bluyssen, PM
    Cox, C
    [J]. ENERGY AND BUILDINGS, 2002, 34 (02) : 155 - 162
  • [6] Enhancing indoor air quality in office buildings: Insight from a field study
    Torriani, Giulia
    Lara-Ibeas, Irene
    Babich, Francesco
    [J]. 53RD AICARR INTERNATIONAL CONFERENCE FROM NZEB TO ZEB: THE BUILDINGS OF THE NEXT DECADES FOR A HEALTHY AND SUSTAINABLE FUTURE, 2024, 523
  • [7] The effect of ventilation on the indoor environment quality in a natural ventilated office building, a case study
    Avgeilis, A.
    Papadopoulos, A. M.
    [J]. Proceedings of the 8th International Conference on Environmental Science and Technology, Vol A, Oral Presentations, 2003, : 44 - 51
  • [8] Creation of the Indoor Environment in Office Buildings
    Sowa, Jerzy
    [J]. ASHRAE JOURNAL, 2020, 62 (07) : 64 - 67
  • [9] Creation of the indoor environment in office buildings
    SOWA, JERZY
    [J]. ASHRAE Journal, 2020, 62 (07): : 64 - 68
  • [10] A study of ventilation performance of an underfloor and overhead air distribution system
    Chang, Jae D.
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1202 - 1209