A photon recycling approach to the denoising of ultra-low dose X-ray sequences

被引:7
|
作者
Hariharan, Sai Gokul [1 ,2 ]
Strobel, Norbert [2 ,3 ]
Kaethner, Christian [2 ]
Kowarschik, Markus [1 ,2 ]
Demirci, Stefanie [1 ]
Albarqouni, Shadi [1 ]
Fahrig, Rebecca [2 ,5 ]
Navab, Nassir [1 ,4 ]
机构
[1] Tech Univ Munich, Comp Aided Med Procedures, Munich, Germany
[2] Siemens Healthcare GmbH, Adv Therapies, Forchheim, Germany
[3] Hsch Angew Wissensch Wurzburg Schweinfurt, Fak Elektrotech, Schweinfurt, Germany
[4] Johns Hopkins Univ, Whiting Sch Engn, Baltimore, MD USA
[5] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
关键词
Spatio-temporal denoising; Ultra-low dose X-ray sequences; Low-rank approximation; FLUOROSCOPY; NOISE; DIFFUSION; ALGORITHM; IMAGES;
D O I
10.1007/s11548-018-1746-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical procedures that make use of fluoroscopy may expose patients as well as the clinical staff (throughout their career) to non-negligible doses of radiation. The potential consequences of such exposures fall under two categories, namely stochastic (mostly cancer) and deterministic risks (skin injury). According to the "as low as reasonably achievable" principle, the radiation dose can be lowered only if the necessary image quality can be maintained. Our work improves upon the existing patch-based denoising algorithms by utilizing a more sophisticated noise model to exploit non-local self-similarity better and this in turn improves the performance of low-rank approximation. The novelty of the proposed approach lies in its properly designed and parameterized noise model and the elimination of initial estimates. This reduces the computational cost significantly. The algorithm has been evaluated on 500 clinical images (7 patients, 20 sequences, 3 clinical sites), taken at ultra-low dose levels, i.e. 50% of the standard low dose level, during electrophysiology procedures. An average improvement in the contrast-to-noise ratio (CNR) by a factor of around 3.5 has been found. This is associated with an image quality achieved at around 12 (square of 3.5) times the ultra-low dose level. Qualitative evaluation by X-ray image quality experts suggests that the method produces denoised images that comply with the required image quality criteria. The results are consistent with the number of patches used, and they demonstrate that it is possible to use motion estimation techniques and "recycle" photons from previous frames to improve the image quality of the current frame. Our results are comparable in terms of CNR to Video Block Matching 3D-a state-of-the-art denoising method. But qualitative analysis by experts confirms that the denoised ultra-low dose X-ray images obtained using our method are more realistic with respect to appearance.
引用
收藏
页码:847 / 854
页数:8
相关论文
共 50 条
  • [1] A photon recycling approach to the denoising of ultra-low dose X-ray sequences
    Sai Gokul Hariharan
    Norbert Strobel
    Christian Kaethner
    Markus Kowarschik
    Stefanie Demirci
    Shadi Albarqouni
    Rebecca Fahrig
    Nassir Navab
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 847 - 854
  • [2] Neural Denoising of Ultra-low Dose Mammography
    Green, Michael
    Sklair-Levy, Miri
    Kiryati, Nahum
    Konen, Eli
    Mayer, Arnaldo
    [J]. MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION, MLMIR 2019, 2019, 11905 : 215 - 225
  • [3] Tabletop x-ray ghost imaging with ultra-low radiation
    Zhang, Ai-Xin
    He, Yu-Hang
    Wu, Ling-An
    Chen, Li-Ming
    Wang, Bing-Bing
    [J]. OPTICA, 2018, 5 (04): : 374 - 377
  • [4] AN ULTRA-LOW STRESS TUNGSTEN ABSORBER FOR X-RAY MASKS
    ITOH, M
    HORI, M
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1991, 9 (01): : 165 - 168
  • [5] Ultra low dose X-ray spinal examinations
    Fessler, P
    Prevot, G
    Hilt, B
    [J]. RESEARCH INTO SPINAL DEFORMITIES 3, 2002, 88 : 191 - 195
  • [6] AN X-RAY STUDY OF CRYSTALLIZATION IN ERYTHROCYTE SUSPENSIONS AT ULTRA-LOW TEMPERATURES
    VINOGRAD.FR
    KUDRYASH.SN
    RAZUMOVA, LL
    [J]. DOKLADY AKADEMII NAUK SSSR, 1966, 169 (05): : 1184 - &
  • [7] REDUCING THE BACKGROUND OF ULTRA-LOW TEMPERATURE X-RAY DIFFRACTION DATA
    McMonagle, Charlie
    Probert, Michael
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : E257 - E257
  • [8] Multivariate Analysis on the Electric Currents Measured by a "transXend" Detector for Ultra-low Dose Exposure X-ray Diagnosis
    Kanno, Ikuo
    Shimazaki, Hironobu
    Imamura, Ryo
    Shima, Kazunari
    Yamashita, Yoshiki
    Ohtaka, Masahiko
    Hashimoto, Makoto
    Ara, Kuniaki
    Onabe, Hideaki
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3219 - 3222
  • [9] Learning Real Noise for Ultra-Low Dose Lung CT Denoising
    Green, Michael
    Marom, Edith M.
    Konen, Eli
    Kiryati, Nahum
    Mayer, Arnaldo
    [J]. PATCH-BASED TECHNIQUES IN MEDICAL IMAGING, PATCH-MI 2018, 2018, 11075 : 3 - 11
  • [10] Ultra-Low Dose Chest CT with Denoising for Lung Nodule Detection
    Kerpel, Ariel
    Marom, Edith Michelle
    Green, Michael
    Eifer, Michal
    Konen, Eli
    Mayer, Arnaldo
    Cuellar, Sonia L. Betancourt
    [J]. ISRAEL MEDICAL ASSOCIATION JOURNAL, 2021, 23 (09): : 550 - 555