Effect of registration method on clinical accuracy of image guided pedicle screw surgery

被引:0
|
作者
Glossop, N [1 ]
Hu, R [1 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Div Orthopaed Surg, Toronto, ON M4N 3M5, Canada
来源
CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY | 1997年 / 1134卷
关键词
D O I
暂无
中图分类号
R-058 [];
学科分类号
摘要
This study was performed to test the effect of surface fitting on the clinical accuracy of image guided spine surgery. In all, ten pedicles in the spine of a 95 year old human cadaver were registered using a combination of paired point registration and surface fitting. The apparent position of the pedicle probe was recorded in surgery, and a proxy pedicle screw inserted. Postoperative analysis compared the apparent positions of the pedicle probe using registrations calculated using just the paired points and then the paired point/surface fitting combination with the position of the proxy on a postoperative scan. No statisticlly significant difference was found between the two registration methods, but we caution that these results are still preliminary.
引用
收藏
页码:884 / 888
页数:5
相关论文
共 50 条
  • [1] Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Kato, Hiroyuki
    SPINE, 2010, 35 (03) : 347 - 352
  • [2] Clinical Pedicle Screw Accuracy and Deviation From Planning in Robot-Guided Spine Surgery
    van Dijk, Joris D.
    van den Ende, Roy P. J.
    Stramigioli, Stefano
    Koechling, Matthias
    Hoess, Norbert
    SPINE, 2015, 40 (17) : E986 - E991
  • [3] Accuracy requirements for image-guided spinal pedicle screw placement
    Rampersaud, YR
    Simon, DA
    Foley, KT
    SPINE, 2001, 26 (04) : 352 - 359
  • [4] Bone registration method for robot assisted surgery: Pedicle screw insertion
    AbdelMalek, K
    McGowan, DP
    Goel, VK
    Kowalski, D
    Smith, SB
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) : 221 - 233
  • [5] Image-guided pedicle screw insertion accuracy: a meta-analysis
    Tian, Nai-Feng
    Xu, Hua-Zi
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 895 - 903
  • [6] Image-guided pedicle screw insertion accuracy: a meta-analysis
    Nai-Feng Tian
    Hua-Zi Xu
    International Orthopaedics, 2009, 33 : 895 - 903
  • [7] Comparison of Accuracy of Pedicle Screw Insertion Among 4 Guided Technologies in Spine Surgery
    Fan, Yong
    Du, Jinpeng
    Zhang, Jianan
    Liu, Shichang
    Xue, Xukai
    Huang, Yunfei
    Zhang, Jing
    Hao, Dingjun
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5960 - 5968
  • [8] The Effect of Thoracolumbar Pedicle Isthmus on Pedicle Screw Accuracy
    Raasck, Kyle
    Khoury, Jason
    Aoude, Ahmed
    Beland, Benjamin
    Munteanu, Alexander
    Weber, Michael H.
    Golan, Jeff
    GLOBAL SPINE JOURNAL, 2020, 10 (04) : 393 - 398
  • [9] Clinical use accuracy in image guided surgery
    Glossop, N
    Hu, R
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 889 - 893
  • [10] Accuracy of Fiducial Marker Based Multimodal Image Registration in Image Guided Surgery
    Zhang Hongwei
    Wang Guangzhi
    Ding Hui
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1538 - +