Detecting Insulation Condition Changes of Inverter Fed AC Machines Based on Two Current Sensors and Indirect Phase Step Excitation

被引:0
|
作者
Zoeller, C. [1 ]
Vogelsberger, M. A. [2 ]
Wiedner, H. D. [1 ]
Riefer, J. [2 ]
Wolbank, Th. M. [1 ]
机构
[1] Vienna Univ Technol, Inst Energy Syst & Elect Drives, A-1040 Vienna, Austria
[2] Bombardier Transport Austria GmbH, Drives Dev Ctr 1, PPC, Vienna, Austria
关键词
Variable speed drives; Fault detection; Induction motors; Insulation degradation; Condition monitoring; Power system transients; SYSTEMS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A high number of breakdowns of adjustable speed drives (ASD) is caused by a fault of the machine, especially stator related insulation faults frequently occur. The evaluation of the insulation condition is possible with the current sensor signals only. The analyses of the transient part of the current response give evidence if a change in the insulation system occurred. The degradation of the insulation state is noticeable through a capacitive change, which influences the high frequency behavior of the machine and as a consequence the transient part of the current signal. The proposed method is capable to detect insulation degradation through analyzing the transient current response of the sensors already used for the control of the machine. Additionally, the profitable capital expenditure demands the design with minimal number of components. To reduce the costs only two current sensors are available. The non-measured transient phase current response can be reconstructed by a special excitation sequence and signal processing without significant deterioration of sensitivity.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 15 条
  • [1] Insulation monitoring of three phase inverter-fed ac machines based on two current sensors only
    Zoeller, C.
    Vogelsberger, M. A.
    Nussbaumer, P.
    Wolbank, Th. M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 1901 - 1907
  • [2] Stimulating and detecting changes in the insulation health state of inverter fed ac machines
    Zoeller, C.
    Vogelsberger, M. A.
    Nussbaumer, P.
    Wolbank, Th. M.
    [J]. 2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [3] Increasing Accuracy of Winding Insulation State Indicator of Three Phase Inverter-fed Machines using Two Current Sensors only
    Zoeller, C.
    Winter, Th
    Wolbank, Th M.
    Vogelsberger, M. A.
    [J]. 2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 811 - 816
  • [4] Stator insulation monitoring of inverter-fed machines based on current transient evaluation
    Zoeller, C.
    Vogelsberger, M. A.
    Wolbank, T. M.
    [J]. ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2018, 135 (02): : 145 - 152
  • [5] Detection of rotor eccentricity caused air gap asymmetries in inverter fed AC machines based on current step response
    Wolbank, TM
    Macheiner, P
    Machl, JL
    Hauser, H
    [J]. PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 468 - 473
  • [6] Inverter-fed Drive Stator Insulation Monitoring Based on Reflection Phenomena Stimulated by Voltage Step Excitation
    Zoeller, C.
    Wolbank, Th. M.
    Vogelsberger, M. A.
    [J]. 2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [7] Comparative Study of Neutral-Voltage-Based and Leakage-Current-Based Online Condition Monitoring Methods for Stator Insulation of Inverter-Fed Machines
    Zheng, Dayong
    Lu, Geye
    Qu, Jianzhen
    Zhang, Yongchang
    Zhang, Pinjia
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024,
  • [8] Influence of Voltage Excitation and Current Sensors on Monitoring of Stator Winding Insulation based on Transient Current Step Response
    Zoeller, C.
    Wolbank, Th. M.
    Vogelsberger, M. A.
    [J]. 2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 2854 - 2861
  • [9] Detection of AC Machines Insulation Health State based on Evaluation of Switching Transients using Two Current Sensors and Eigenanalysis-based Parameter Estimation
    Zoeller, C.
    Winter, Th.
    Wolbank, Th. M.
    Vogelsberger, M. A.
    [J]. 2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 3111 - 3118
  • [10] An improved observer-based current controller for inverter fed AC machines with single DC-link current measurement
    Wolbank, TM
    Macheiner, P
    [J]. PESC'02: 2002 IEEE 33RD ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2002, : 1003 - 1008