An Examination of the Techno-Economic Viability of Hybrid Grid-Integrated and Stand-Alone Generation Systems for an Indian Tea Plant

被引:14
|
作者
Thirunavukkarasu, M. [1 ]
Sawle, Yashwant [1 ]
机构
[1] Vellore Inst Technol, Sch Elect Engn, Vellore, Tamil Nadu, India
关键词
hybrid renewable sources; tri-generation; thermal load controller; combined heat and power; levelized cost of electricity; levelized cost of hydrogen; homer; HYDROGEN REFUELING STATION; ENERGY SYSTEM; RURAL ELECTRIFICATION; FEASIBILITY ANALYSIS; SENSITIVITY-ANALYSIS; ECONOMIC-ANALYSIS; POWER-GENERATION; OPTIMAL-DESIGN; COMBINED HEAT; PV;
D O I
10.3389/fenrg.2022.806870
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
All tea plants in India rely on the national grid for their electrical needs and diesel for their thermal energy and transportation, which are encountering high costs, high emissions, and issues of accessibility. In this paper, hybrid renewable systems based on both standalone and grid-connected technologies have been modeled using HOMER Pro software for supplying power to a tea manufacturing plant in a typical rural area in India, namely, Gudalur village (Nilgiris), geographically located at 11 degrees 30.2 ' N and 76 degrees 29.5 ' E, which is presently run by the state grid to meet their energy requirements. The different configurations comprised of Solar PV, biomass, hydro, electrolyzer, boiler, thermal load controller to utilize excess electricity, and waste heat recovery options, and lead-acid batteries were designed to meet 650 kWh/day of electricity for processing units, 101 kWh/day of electricity for general applications, 4,450 kWh/day of thermal energy, and 86.35 kg/day of hydrogen energy. To determine the most feasible system design among various scenarios, several criteria such as NPC, COE, LCOH, and CO2 emission of the system have been investigated. In the case of off-grid hybrid systems, results show the highest NPC of $7.01 M with an LCOE of $1.06/kWh is obtained for the diesel generator/boiler/reformer/TLC system. It is reduced to $1.75 M with an LCOE of -$.420/kWh for the PV/biomass-CHP/hydro/TLC scenario. In a grid-connected system, the maximum NPC of $6.20 M with an LCOE of $0.835/kWh is obtained for a diesel generator/boiler system, and it is reduced to -$10.5 M with an LCOE of -$.240/kWh for the PV/biomass-CHP/hydro/TLC scenario. Additionally, in the off-grid systems, the PV/biomass-CHP/hydro/TLC system has LCOH of $4.27/kg, which is economical with the highest renewable fraction of 93%. The PV/biomass-CHP/hydro/TLC hybrid system has the lowest LCOH of -$64.5/kg with a maximum renewable fraction of 96% in on-grid systems. The findings show that recovering excess electricity and waste heat would increase renewable fraction, decrease the energy cost and emissions from the system, and emphasize the importance of TLC and CHP in HRES. According to the simulation results, the grid-connected system is more cost-effective than a stand-alone system due to the revenue obtained from selling renewable power to the grid.
引用
收藏
页数:30
相关论文
共 50 条
  • [1] Sizing and techno-economic analysis of stand-alone hybrid photovoltaic/wind/diesel/battery power generation systems
    Mohamed, Mohamed A.
    Eltamaly, Ali M.
    Alolah, Abdulrahman I.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (06)
  • [2] Feasibility analysis of biomass-based grid-integrated and stand-alone hybrid energy systems for a cement plant in India
    Makhija, Satya Prakash
    Dubey, S. P.
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2019, 21 (02) : 861 - 878
  • [3] Feasibility analysis of biomass-based grid-integrated and stand-alone hybrid energy systems for a cement plant in India
    Satya Prakash Makhija
    S. P. Dubey
    Environment, Development and Sustainability, 2019, 21 : 861 - 878
  • [4] A techno-economic feasibility of a stand-alone hybrid power generation for remote area application in Bangladesh
    Das, Barun K.
    Hoque, Najmul
    Mandal, Soumya
    Pal, Tapas Kumar
    Abu Raihan, Md
    ENERGY, 2017, 134 : 775 - 788
  • [5] Techno-economic Assessement of Hybrid Energy System for a Stand-Alone Load in Morocco
    El Haini, Jamila
    Saka, Abdelmjid
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (04): : 1774 - 1782
  • [6] Techno-economic optimization of hybrid photovoltaic/wind/diesel/battery generation in a stand-alone power system
    Kaabeche, Abdelhamid
    Ibtiouen, Rachid
    SOLAR ENERGY, 2014, 103 : 171 - 182
  • [7] Techno-economic feasibility of photovoltaic, wind and hybrid electrification systems for stand-alone and grid-connected shipyard electrification in Italy
    Vakili, Seyedvahid
    Schonborn, Alessandro
    Olcer, Aykut, I
    JOURNAL OF CLEANER PRODUCTION, 2022, 366
  • [8] Techno-economic analysis of a stand-alone solar desalination plant at variable load conditions
    Laissaoui, Mohammed
    Palenzuela, Patricia
    Eldean, Mohamed A. Sharaf
    Nehari, Driss
    Alarcon-Padilla, Diego-Cesar
    APPLIED THERMAL ENGINEERING, 2018, 133 : 659 - 670
  • [9] Techno-Economic Analysis of a Stand-Alone Hybrid System: Application in Donoussa Island, Greece
    Katsivelakis, Michail
    Bargiotas, Dimitrios
    Daskalopulu, Aspassia
    Panapakidis, Ioannis P.
    Tsoukalas, Lefteri
    ENERGIES, 2021, 14 (07)
  • [10] Design and Techno-Economic Analysis of Optimised Stand-Alone Hybrid Energy Systems for Telecom Infrastructure in the Arid Zones
    Mathur, Tanmay
    Tikkiwal, Vinay Anand
    Gupta, Tanya
    Gupta, Shreya
    Kumar, Arun
    PROCEEDINGS OF THE 2019 6TH INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2019, : 12 - 17