Accuracy of endoscopic ultrasound-fine needle aspiration of solid lesions over time: Experience from a new endoscopic ultrasound program at a Canadian community hospital

被引:2
|
作者
Cooray, Mohan [1 ]
Nistor, Irina [2 ]
Pham, Joe [2 ]
Bair, Douglas [2 ]
Arya, Naveen [2 ]
机构
[1] McMaster Univ, Div Gastroenterol, Dept Med, Hamilton, ON, Canada
[2] Oakville Trafalgar Mem Hosp, Div Gastroenterol, Dept Med, Oakville, ON, Canada
关键词
Accuracy; cytotechnologist; endoscopic ultrasound; fine needle aspiration; learning curves; rapid-on-site evaluation; EUS-GUIDED FNA; PANCREATIC MASSES; ON-SITE; DIAGNOSTIC-ACCURACY; RANDOMIZED-TRIAL; METAANALYSIS; INCREASES; CANCER; BIOPSY; IMPACT;
D O I
10.4103/2303-9027.208177
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Objectives: A Canadian Community Hospital launched a new Endoscopic Ultrasound (EUS) Program in 2011. The aim of this study was to report the accuracy of EUS-fine needle aspiration (EUS-FNA) of solid lesions over time as it pertains to cytotechnologists' involvement and learning curves. Methods: The electronic medical records of patients that had a EUS from July 2011 to January 2014 were retrospectively reviewed. Only solid lesions with FNA sampling were included in the study. The primary outcome assessed was the accuracy of specimen acquisition for pathological review. The secondary outcome was diagnostic accuracy. Cases were separated by chronological order into thirds for the assessment of learning curves. Cytotechnologists' involvement was correlated to determine its impact on accuracy. Results: Two hundred and seventy-one EUS-FNA procedures were completed for solid lesions. Cytotechnologists' involvement resulted in a specimen acquisition accuracy of 82.6%, compared with 68.8% without a cytotechnologist (P = 0.009; 95% confidence interval [CI] 3.2%-25.0%). Diagnostic accuracy was 74.2% with a cytotechnologist while 62.4% without a cytotechnologist (P = 0.038; 95% CI 0.3%-23.7%). The specimen acquisition accuracy increased from 73.2% from the first third of cases to 92.3% for the last third with a cytotechnologist (P = 0.004; 95% CI 6%-33.0%). Without a cytotechnologist, the specimen accuracy was 67.6% for the first third while 57.7% for the last third of cases (P = 0.434; 95% CI -33.9-14.4%). In the multivariable regression analysis, after adjusting for other predictors, a present cytotechnologist (P = 0.022) and lesion size 21 mm-30 mm (P = 0.039) and > 30 mm (P = 0.001) were significantly associated with increased specimen acquisition accuracy. Only a present cytotechnologist (P = 0.046) was significantly associated with increased diagnostic accuracy. Interpretation: Cytotechnologists' involvement significantly improved the accuracy of specimen acquisition. Although accuracy was impacted by a cytotechnologist learning curve, our results highlight the importance of a cytotechnologist being present for EUS-FNA sampling of solid lesions.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 50 条
  • [1] Endoscopic ultrasound fine needle aspiration of solid pancreatic lesions: experience at a community hospital
    Elias, Georg
    Toubia, Nabil
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 : S523 - S523
  • [2] Endoscopic ultrasound fine needle aspiration of solid pancreatic lesions: Experience at a community hospital
    Butnariu, Madalina
    Goodman, Adam
    Rein, Matthew
    O'Brien, Daniel
    Abotaga, Shareef
    Gress, Frank
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 : S523 - S523
  • [3] Acute Pancreatitis as a Complication of Endoscopic Ultrasound-Fine Needle Aspiration
    Nigam, Neha
    Liu, Eashen
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 : S345 - S345
  • [4] SUBEPITHELIAL LESIONS OF THE GASTROINTESTINAL TRACT: DIAGNOSTIC YIELD OF ENDOSCOPIC ULTRASOUND-FINE NEEDLE ASPIRATION
    De Angelis, C. G.
    Manfre, S. F.
    Marietti, M.
    Bruno, M.
    Carucci, P.
    Maldi, E.
    Pacchioni, D.
    Accinelli, G.
    Cassoni, P.
    Di Celle, P. Francia
    [J]. DIGESTIVE AND LIVER DISEASE, 2014, 46 : S61 - S61
  • [5] Endoscopic ultrasound-fine needle aspiration for the diagnosis of lymphoma: Are we there yet?
    Kwan, Vu
    Gottlieb, David
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (12) : 1808 - 1809
  • [6] DIAGNOSTIC ACCURACY OF ENDOSCOPIC ULTRASOUND ELASTOGRAPHY TARGETED FINE NEEDLE ASPIRATION FOR SOLID PANCREATIC LESIONS
    Facciorusso, A.
    Di Maso, M.
    Serviddio, G.
    Del Prete, V.
    Muscatiello, N.
    [J]. DIGESTIVE AND LIVER DISEASE, 2017, 49 : E171 - E172
  • [7] Diagnostic Accuracy of Endoscopic Ultrasound Guided Fine Needle Aspiration of Pancreatic Lesions
    Ironside, A.
    Young, M.
    [J]. JOURNAL OF PATHOLOGY, 2010, 222 : S45 - S45
  • [8] Two-center experience with a new nitinol endoscopic ultrasound-fine needle aspiration/fine needle biopsy needle: Initial results
    Tee, D.
    Lim, K.
    Ruszkiewicz, A.
    Zhang, C.
    Davis, A.
    Tam, W.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 52 - 52
  • [9] Comparison of Endoscopic Ultrasound-Fine-Needle Aspiration and Endoscopic Ultrasound-Fine-Needle Biopsy for Solid Lesions in a Multicenter, Randomized Trial
    Nagula, Satish
    Pourmand, Kamron
    Aslanian, Harry
    Bucobo, Juan Carlos
    Gonda, Tamas A.
    Gonzalez, Susana
    Goodman, Adam
    Gross, Seth A.
    Ho, Sammy
    DiMaio, Christopher J.
    Kim, Michelle K.
    Pais, Shireen
    Poneros, John M.
    Robbins, David H.
    Schnoll-Sussman, Felice
    Sethi, Amrita
    Buscaglia, Jonathan M.
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2018, 16 (08) : 1307 - +
  • [10] AUDIT OF ENDOSCOPIC ULTRASOUND GUIDED FINE NEEDLE ASPIRATION OF SOLID PANCREATIC LESIONS
    Rajkumar, S.
    Harris, K.
    Aldersley, M.