Comparison of diffusion-weighted imaging and MR elastography in staging liver fibrosis: a meta-analysis

被引:11
|
作者
Jang, Weon [1 ,2 ,3 ]
Jo, Seongil [4 ]
Song, Ji Soo [1 ,2 ,3 ]
Hwang, Hong Pil [5 ]
Kim, Seong-Hun [6 ]
机构
[1] Jeonbuk Natl Univ Med Sch & Hosp, Dept Radiol, Jeonju, South Korea
[2] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju, South Korea
[3] Jeonbuk Natl Univ Hosp, Biomed Res Inst, 20 Geonji Ro, Jeonju 54907, Jeonbuk, South Korea
[4] Inha Univ, Dept Stat, Incheon, South Korea
[5] Jeonbuk Natl Univ Med Sch & Hosp, Dept Surg, Jeonju, South Korea
[6] Jeonbuk Natl Univ Med Sch & Hosp, Dept Internal Med, Jeonju, South Korea
关键词
Liver fibrosis; Magnetic resonance elastography; Diffusion-weighted image; Meta-analysis; MAGNETIC-RESONANCE ELASTOGRAPHY; CHRONIC HEPATITIS-B; INTRAVOXEL INCOHERENT MOTION; DIAGNOSTIC-TEST ACCURACY; RADIATION FORCE IMPULSE; GRADIENT-RECALLED ECHO; TRANSIENT ELASTOGRAPHY; NONINVASIVE EVALUATION; VIRAL-HEPATITIS; PERFORMANCE;
D O I
10.1007/s00261-021-03055-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare the diagnostic performance of diffusion-weighted imaging (DWI), gradient-recalled echo-based magnetic resonance elastography (GRE-MRE), and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging. Methods A systematic literature search was done to collect studies on the performance of DWI, GRE-MRE, and SE-EPI-MRE for diagnosing liver fibrosis. Pooled sensitivity, specificity, diagnostic odds ratio, positive and negative likelihood ratio, and a summary receiver operating characteristic (ROC) curve were estimated with a bivariate random effects model. Subgroup analyses on various study characteristics were performed. Results Sixty studies with a total of 6620 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE showed high diagnostic accuracy and did not differ significantly. The area under the summary ROC curve for all stages of fibrosis differed significantly between DWI (0.83-0.88) and either GRE-MRE (0.95-0.97) or SE-EPI-MRE (0.95-0.99). Substantial heterogeneity was detected for all three imaging methods. Conclusions Both GRE-MRE and SE-EPI-MRE are highly accurate for detection of each liver fibrosis stage, with high potential to replace liver biopsy. Although DWI had a moderate accuracy in distinguishing liver fibrosis, it could be regarded as an alternative to MRE, since it is widely available and easily implemented in routine liver MRI.
引用
收藏
页码:3889 / 3907
页数:19
相关论文
共 50 条
  • [1] Comparison of diffusion-weighted imaging and MR elastography in staging liver fibrosis: a meta-analysis
    Weon Jang
    Seongil Jo
    Ji Soo Song
    Hong Pil Hwang
    Seong-Hun Kim
    Abdominal Radiology, 2021, 46 : 3889 - 3907
  • [2] Comparison of diffusion-weighted imaging and MR elastography in staging liver fibrosis: a meta-analysis (vol 46, pg 3889, 2021)
    Jang, Weon
    Jo, Seongil
    Song, Ji Soo
    Hwang, Hong Pil
    Kim, Seong-Hun
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2763 - 2768
  • [3] Correction to: Comparison of diffusion‑weighted imaging and MR elastography in staging liver fibrosis: a meta‑analysis
    Weon Jang
    Seongil Jo
    Ji Soo Song
    Hong Pil Hwang
    Seong-Hun Kim
    Abdominal Radiology, 2023, 48 : 2763 - 2768
  • [4] Liver fibrosis staging with diffusion-weighted imaging: a systematic review and meta-analysis
    Hanyu Jiang
    Jie Chen
    Ronghui Gao
    Zixing Huang
    Mingpeng Wu
    Bin Song
    Abdominal Radiology, 2017, 42 : 490 - 501
  • [5] Liver fibrosis staging with diffusion-weighted imaging: a systematic review and meta-analysis
    Jiang, Hanyu
    Chen, Jie
    Gao, Ronghui
    Huang, Zixing
    Wu, Mingpeng
    Song, Bin
    ABDOMINAL RADIOLOGY, 2017, 42 (02) : 490 - 501
  • [6] Performance of magnetic resonance elastography and diffusion-weighted imaging for the staging of hepatic fibrosis: A meta-analysis
    Wang, Qing-Bing
    Zhu, Hui
    Liu, Hai-Ling
    Zhang, Bei
    HEPATOLOGY, 2012, 56 (01) : 239 - 247
  • [7] Comparison of Magnetic Resonance Elastography and Diffusion-weighted Imaging for Staging Hepatic Fibrosis
    Zou, Li-Qiu
    Chen, Jie
    Pan, Liang
    Jiang, Jin-Zhao
    Xing, Wei
    CHINESE MEDICAL JOURNAL, 2015, 128 (05) : 620 - 625
  • [8] Comparison of Magnetic Resonance Elastography and Diffusion-weighted Imaging for Staging Hepatic Fibrosis
    Zou Li-Qiu
    Chen Jie
    Pan Liang
    Jiang Jin-Zhao
    Xing Wei
    中华医学杂志英文版, 2015, 128 (05) : 620 - 625
  • [9] Assessment of diffusion-weighted MR imaging in liver fibrosis
    Annet, Laurence
    Peeters, Frank
    Abarca-Quinones, Jorge
    Leclercq, Isabelle
    Moulin, Pierre
    Van Beers, Bernard E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 122 - 128
  • [10] Diffusion-weighted Magnetic Resonance Imaging for the Staging of Liver Fibrosis
    Bonekamp, Susanne
    Torbenson, Michael S.
    Kamel, Ihab R.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2011, 45 (10) : 885 - 892