3D reconstruction: Why should the accuracy always be presented in the pixel unit?

被引:0
|
作者
Mertens, Benjamin [1 ]
Delchambre, Alain [1 ]
机构
[1] Univ Libre Bruxelles, BEAMS Dept, Ave F Roosevelt 50,CP 165-56, B-1050 Brussels, Belgium
关键词
Error; Structured light; Stereoscopy; Pixel; Parallax;
D O I
10.1016/j.imavis.2016.02.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper analyses the error presentation of parallax-based techniques (mainly stereoscopy and structured light). They are usually presented using an absolute (mm) or a relative (%) scale. These results are hard to compare between different systems as they are system-dependent. This paper presents results using the pixel unit which avoids the influence of geometric parameters. Moreover it is apt at evaluating whether the system under-performs or is similar compared to theoretical accuracy. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 50 条
  • [1] 3D Semantic Trajectory Reconstruction from 3D Pixel Continuum
    Yoon, Jae Shin
    Li, Ziwei
    Park, Hyun Soo
    2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2018, : 5060 - 5069
  • [2] ACCURACY OF 3D RECONSTRUCTION IN AN ILLUMINATION DOME
    MacDonald, Lindsay
    Toschi, Isabella
    Nocerino, Erica
    Hess, Mona
    Remondino, Fabio
    Robson, Stuart
    XXIII ISPRS Congress, Commission V, 2016, 41 (B5): : 69 - 76
  • [3] Why should we do 3D integration?
    Haensch, Wilfried
    2008 45TH ACM/IEEE DESIGN AUTOMATION CONFERENCE, VOLS 1 AND 2, 2008, : 674 - 675
  • [4] 3D Object Reconstruction Using Full Pixel Matching
    Yaguchi, Yuichi
    Iseki, Kenta
    Viet, Nguyen Tien
    Oka, Ryuichi
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2009, 5702 : 873 - 880
  • [5] 3D scene reconstruction: Why, when, and how?
    McBride, JC
    Snorrason, MS
    Goodsell, TR
    Eaton, RS
    Stevens, MR
    UNMANNED GROUND VEHICLE TECHNOLOGY VI, 2004, 5422 : 76 - 85
  • [6] On the accuracy of Independent Pixel Approximation in 3D radiative transfer calculation
    Scheirer, R
    Macke, A
    IRS 2000: CURRENT PROBLEMS IN ATMOSPHERIC RADIATION, 2001, : 229 - 232
  • [7] 3D IMAGING AND UROLOGY: WHY 3D RECONSTRUCTION WILL BE MANDATORY BEFORE PERFORMING SURGERY
    Lachkar, Amane-Allah
    Soler, Luc
    Diana, Michele
    Becmeur, Francois
    Marescaux, Jacques
    ARCHIVOS ESPANOLES DE UROLOGIA, 2019, 72 (03): : 347 - 352
  • [8] Influence of camera calibration conditions on the accuracy of 3D reconstruction
    Poulin-Girard, Anne-Sophie
    Thibault, Simon
    Laurendeau, Denis
    OPTICS EXPRESS, 2016, 24 (03): : 2678 - 2686
  • [9] INFLUENCE OF CT SCANNER CHARACTERISTICS ON 3D RECONSTRUCTION ACCURACY
    DORE, S
    KEARNEY, RE
    DEGUISE, J
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY CONFERENCE : PROCEEDINGS - 1989, 1989, : 25 - 26
  • [10] Quantitative Assessment of the Accuracy of 3D Face Shape Reconstruction
    Amin, S. Hassan
    Gillies, Duncan Fyfe
    2008 IEEE SECOND INTERNATIONAL CONFERENCE ON BIOMETRICS: THEORY, APPLICATIONS AND SYSTEMS (BTAS), 2008, : 314 - +