Portable Interactive Pulse Tactile Recorder and Player System

被引:6
|
作者
Hsieh, Tzu-Chieh [1 ]
Wu, Chien-Min [1 ]
Tsai, Cheng-Chung [1 ]
Lo, Wen-Chien [1 ]
Wang, Yu-Min [1 ]
Smith, Shana [1 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, Taipei 10617, Taiwan
关键词
artificial neural network; empirical mode decomposition; intrinsic mode functions; pulse tactile player; pulse tactile recorder; EMPIRICAL MODE DECOMPOSITION; WAVE-FORM; SENSOR; BEHAVIOR;
D O I
10.3390/s21134339
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pulse palpation is an effective method for diagnosing arterial diseases. However, most pulse measurement devices use preconfigured pressures to collect pulse signals, and most pulse tactile simulators can only display standard or predefined pulse waveforms. Here, a portable interactive human pulse measurement and reproduction system was developed that allows users to take arbitrary pulses and experience realistic simulated pulse tactile feedback in real time by using their natural pulse-taking behaviors. The system includes a pulse tactile recorder and a pulse tactile player. Pulse palpation forces and vibrations can be recorded and realistically replayed for later tactile exploration and examination. To retain subtle but vital pulse information, empirical mode decomposition was used to decompose pulse waveforms into several intrinsic mode functions. Artificial neural networks were then trained based on intrinsic mode functions to determine the relationship between the driving signals of the pulse tactile player and the resulting vibration waveforms. Experimental results indicate that the average normalized root mean square error and the average R-squared values between the reproduced and original pulses were 0.0654 and 0.958 respectively, which indicate that the system can reproduce high-fidelity pulse tactile vibrations.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A Novel Portable Pulse Signal Recorder
    Chen, Xiao
    FBIE: 2008 INTERNATIONAL SEMINAR ON FUTURE BIOMEDICAL INFORMATION ENGINEERING, PROCEEDINGS, 2008, : 340 - 343
  • [2] Electromagnetic interference in an implantable loop recorder caused by a portable digital media player
    Thaker, Jay P.
    Patel, Mehul B.
    Jongnarangsin, Krit
    Liepa, Valdis V.
    Castellani, Mark
    Thakur, Ranjan K.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (10): : 1345 - 1347
  • [3] Tactile-STAR: A Novel Tactile STimulator And Recorder System for Evaluating and Improving Tactile Perception
    Ballardini, Giulia
    Carlini, Giorgio
    Giannoni, Psiche
    Scheidt, Robert A.
    Nisky, Ilana
    Casadio, Maura
    FRONTIERS IN NEUROROBOTICS, 2018, 12
  • [4] System-on-a-chip for portable audio player
    Archibald, Fitzgerald J.
    Polley, Michael O.
    Li, Stephen H.
    Kridner, Jason D.
    ICCE: 2007 DIGEST OF TECHNICAL PAPERS INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 2007, : 447 - +
  • [5] PORTABLE EVENT RECORDER
    GREEN, PB
    MACMILLAN, M
    TRAFFIC ENGINEERING & CONTROL, 1979, 20 (12): : 594 - 595
  • [6] PORTABLE ADJUNCT RECORDER
    BURSTEIN, H
    AUDIO, 1969, 53 (06): : 16 - &
  • [7] Web operation recorder and player
    Aoki, Y
    Ando, F
    Nakajima, A
    SEVENTH INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED SYSTEMS, PROCEEDINGS, 2000, : 501 - 508
  • [8] PILS, A PORTABLE INTERACTIVE LANGUAGE SYSTEM
    RUSSELL, RD
    TREMBLET, L
    WILLIAMS, DO
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (04) : 1272 - 1275
  • [9] Portable EGG recording system based on a digital voice recorder
    Department of Electrical Engineering, Taipei, Taiwan
    不详
    J. Med. Eng. Technol., 2009, 3 (209-213): : 209 - 213
  • [10] PORTABLE TELEVISION TAPE RECORDER
    HANEY, FJ
    IEEE TRANSACTIONS ON BROADCASTING, 1964, BC10 (01) : 27 - &