Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma

被引:14
|
作者
Kogure, S [1 ]
Toda, Y
Crabb, D
Kashiwagi, K
Fitzke, FW
Tsukahara, S
机构
[1] Yamanashi Med Univ, Dept Ophthalmol, Yamanashi 40938, Japan
[2] Nottingham Trent Univ, Dept Math, Nottingham, England
[3] UCL, Inst Ophthalmol, London, England
关键词
D O I
10.1136/bjo.87.5.604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: To investigate the agreement in results between frequency doubling technology (FDT) and the conventional automated static perimeter in eyes with normal tension glaucoma (NTG) and high tension glaucoma (HTG). Methods: 72 eyes of 36 patients, who had two or more experiences with the Humphrey field analyser (HFA) program C30-2, were examined with the screening C-20-1 program of FDT. The result of FDT at each of the 17 stimulus points was graded as one of four categories. 58 out of 76 test points of HFA were assigned to one of the 17 clusters corresponding to FDT test points. Each cluster was represented as the lowest (scotoma of HFA) or the highest (threshold of HFA) probability symbol of total deviation (TD) of the HFA test points included in the cluster. The agreement between scotoma/threshold of HFA and FDT results was evaluated for NTG and HTG. Results: In a total of 65 eyes, the Spearman coefficients between the FDT and HFA (threshold/scotoma of HFA) were 0.599 and 0.515 (p<0.0001), respectively. In the HFA mean deviation matched 20 HTG eyes and 20 NTG eyes, the number of points with abnormal FDT results were 102 and 62 in eyes with HTG and NTG, respectively. The eyes with HTG had more abnormal FDT results than NTG eyes (p=0.0014, Mann-Whitney U test). The kappa coefficient between FDT and threshold of HFA in eyes with HTG and NTG was 0.288 and 0.520, respectively, and the agreement between FDT and scotoma of HFA was 0.480 and 0.439, respectively. Conclusions: The best agreement of the results of FDT and HFA was observed in eyes with NTG using threshold of HFA. The eyes with HTG showed lower agreement with more abnormal points in FDT results, which suggests enough sensitivity of FDT in eyes with NTG, and higher sensitivity of FDT in eyes with HTG.
引用
收藏
页码:604 / 608
页数:5
相关论文
共 50 条
  • [1] Comparison of Frequency Doubling and Humphrey 24-2 Perimetry in normal tension glaucoma
    Bhagat, S
    Ramaesh, K
    Bolton, N
    Barron, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [2] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [3] Comparison of results with frequency doubling perimetry and Humphrey C30-2 in eyes with higher normal tension glaucoma.
    Kogure, S
    Toda, Y
    Crabb, D
    Fitzke, F
    Tsukahara, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S87 - S87
  • [4] Frequency doubling technology perimetry in open-angle glaucoma eyes with hemifield visual field damage: Comparison of high-tension and normal-tension groups
    Murata, Hiroshi
    Tomidokoro, Atsuo
    Matsuo, Hiroshi
    Tomita, Goji
    Araie, Makoto
    JOURNAL OF GLAUCOMA, 2007, 16 (01) : 9 - 13
  • [5] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [6] Comparison of the effectiveness of frequency doubling technology perimetry in detecting abnormalities in primary open-angle glaucoma and normal-tension glaucoma
    Osako, M
    Horikoshi, N
    Tamura, Y
    Okano, T
    Usui, M
    PERIMETRY UPDATE 2000/2001, 2001, : 315 - 315
  • [7] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [8] Performance of frequency doubling perimetry in screening for glaucoma
    Weih, L
    Sakellariou, A
    Rait, J
    McCarty, C
    Taylor, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S477 - S477
  • [9] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [10] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69