Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis

被引:0
|
作者
Chen, Yen-Wei [1 ,2 ]
Duan, Guifang [2 ]
Fujita, Akinori [3 ]
Hirooka, Ken [3 ]
Ueno, Yoshihiro [3 ]
机构
[1] Cent South Univ Forest & Tech, Elect & Inf Eng Sch, Changsha, Hunan, Peoples R China
[2] Ritsumeikan Univ, Grad Sch Sci & Engn, Kyoto, Japan
[3] Shimadzu Co Ltd, Technol Res Lab, Kyoto, Japan
关键词
CBCT image; Ring artifact reduction; Mean filter; Independent component analysis (ICA); MICROTOMOGRAPHY; TOMOGRAPHY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limitation, high image accuracy, rapid scan time, etc. However, In CBCT images there are always some ring artifacts that appear as rings centered on the rotation axis. Due to the data of the constructed images are corrupted by these ring artifacts, qualitative and quantitative analysis of CBCT images will be compromised. Post processing and application such as image segmentation and registration also turn more complex as the presence of such artifacts. In this paper, a method based on independent component analysis (ICA) is presented. It deals with the reconstructed CBCT image and can effectively reduce such ring artifacts.
引用
收藏
页码:1687 / +
页数:3
相关论文
共 50 条
  • [1] INDEPENDENT COMPONENT ANALYSIS BASED RING ARTIFACT REDUCTION IN CONE-BEAM CT IMAGES
    Chen, Yen-Wei
    Duan, Guifen
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 4189 - 4192
  • [2] Reduction of artifacts induced by misaligned geometry in cone-beam CT
    Sun, Yi
    Hou, Ying
    Hu, Jiasheng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) : 1461 - 1471
  • [3] Crescent artifacts in cone-beam CT
    Giles, William
    Bowsher, James
    Li, Hao
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2011, 38 (04) : 2116 - 2121
  • [4] Various procedures for the reduction of cupping artifacts in MegaVoltage Cone-Beam CT
    Petit, S.
    van Elmpt, W.
    Nijsten, S.
    Dekker, A.
    Lambin, P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S232 - S233
  • [5] Cupping artifacts analysis and correction for a FPD-based cone-beam CT
    Zhang Li
    Gao Hewei
    Li Shuanglei
    Chen Zhiqiang
    Xing Yuxiang
    COMPUTATIONAL IMAGING IV, 2006, 6065
  • [6] Reduction of aliasing artifacts in cone-beam CT images using data derivatives with respect to detector coordinates
    Zou, Y
    Pan, X
    Jiang, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [7] Cone-Beam Artifacts in Dedicated Breast CT
    Vedantham, S.
    Shi, L.
    Noo, F.
    Glick, S.
    Karellas, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Iterative Image-Domain Ring Artifacts Removal in Cone-Beam CT
    Liang, X.
    Zhang, Z.
    Yu, S.
    Wu, S.
    Li, Z.
    Xie, Y.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [9] Reducing metal artifacts in cone-beam CT images by preprocessing projection data
    Zhang, Yongbin
    Zhang, Lifei
    Zhu, Ronald
    Lee, Andrew K.
    Chambers, Mark
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 924 - 932
  • [10] Quantitative Evaluation of Metal Artifacts in CT and Cone-Beam CT Images On the Accuracy of Dose Calculation
    Oyewale, S.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3825 - 3825