Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system

被引:31
|
作者
Burmeister, J [1 ]
McDermott, PN
Bossenberger, T
Ben-Josef, E
Levin, K
Forman, JD
机构
[1] Harper Univ Hosp, Karmanos Canc Inst, Gershenson Radiat Oncol Ctr, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI 48201 USA
关键词
intensity modulation; multi-leaf collimator; leaf width; bixel size;
D O I
10.1118/1.1812607
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigates the influence of multileaf collimator (MLC) leaf width on intensity modulated radiation therapy (IMRT) plans delivered via the segmented multileaf collimator (SMLC) technique. IMRT plans were calculated using the Corvus treatment planning system for three brain, three prostate, and three pancreas cases using leaf widths of 0.5 and 1 cm. Resulting differences in plan quality and complexity are presented here. Plans calculated using a 1 cm leaf width were chosen over the 0.5 cm leaf width plans in seven out of nine cases based on clinical judgment. Conversely, optimization results revealed a superior objective function result for the 0.5 cm leaf width plans in seven out of the nine comparisons. The 1 cm leaf width objective function result was superior only for very large target volumes, indicating that expanding the solution space for plan optimization by using narrower leaves may result in a decreased probability of finding the global minimum. In the remaining cases, we can conclude that we are often not utilizing the objective function as proficiently as possible to meet our clinical goals. There was often no apparent clinically significant difference between the two plans, and in such cases the issue becomes one of plan complexity. A comparison of plan complexity revealed that the average 1 cm leaf width plan required roughly 60% fewer segments and over 40% fewer monitor units than required by 0.5 cm leaf width plans. This allows a significant decrease in whole body dose and total treatment time. For very complex IMRT plans, the treatment delivery time may affect the biologically effective dose. A clinically significant improvement in plan quality from using narrower leaves was evident only in cases with very small target volumes or those with concavities that are small with respect to the MLC leaf width. For the remaining cases investigated in this study, there was no clinical advantage to reducing the MLC leaf width from 1 to 0.5 cm. In such cases, there is no justification for the increased treatment time and whole body dose associated with the narrower MLC leaf width. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3187 / 3193
页数:7
相关论文
共 50 条
  • [1] Treatment planning quality and delivery efficiency for SMLC delivered IMRT treatments: Influence of the leaf width of MLC and the size of finite pencil beam
    Zhu, X
    Zhang, S
    Lii, M
    Dong, L
    Kendall, R
    Forster, K
    Shiu, A
    Tung, S
    Gillin, M
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1721 - 1721
  • [2] Commissioning and clinical implementation of Elekta MLC IMRT with Corvus inverse treatment planning
    Wallace, S
    Bobba, V
    Koll, W
    Zhang, Y
    Holt, R
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1896 - 1896
  • [3] Independent validation of CORVUS MLC IMRT dose distributions using ADAC treatment planning system
    Ayyangar, KM
    Saw, CB
    Yoe-Sein, M
    Zhen, W
    Raman, N
    Enke, CA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1271 - 1272
  • [4] The assessment and pre-clinical evaluation of an inverse treatment planning system for SMLC IMRT
    Kelly, C
    Thirion, P
    Petnehazi, C
    O'Neill, L
    Buckney, S
    Mc Clean, B
    Armstrong, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S77 - S77
  • [5] Incorporating the delivery efficiency into the inverse IMRT planning system
    Sun, X
    Xia, P
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1490 - 1490
  • [6] IMRT and inverse treatment planning
    Kneschaurek, P
    [J]. PROGRESS IN RADIO-ONCOLOGY VII, PROCEEDINGS, 2001, : 203 - 212
  • [7] Optimizing the MLC Model Parameters for IMRT in the RayStation Treatment Planning System
    Chen, S.
    Yi, B.
    Xu, H.
    Yang, X.
    Prado, K.
    D' Souza, W.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 362 - +
  • [8] Commissioning of a commercial IMRT treatment planning system for standard elekta MLC
    Kim, H
    Chen, Y
    Xiao, Y
    Anne, P
    Galvin, J
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1348 - 1348
  • [9] Pre-clinical evaluation of an inverse planning module for segmental MLC based IMRT delivery
    Georg, D
    Kroupa, B
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (24): : N303 - N314
  • [10] Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system
    Chen, Shifeng
    Yi, Byong Yong
    Yang, Xiaocheng
    Xu, Huijun
    Prado, Karl L.
    D'Souza, Warren D.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 322 - 332