Non-linear model fitting to parameterize diseased blood vessels

被引:17
|
作者
La Cruz, A [1 ]
Straka, M [1 ]
Köchl, A [1 ]
Srámek, M [1 ]
Gröller, E [1 ]
Fleischmann, D [1 ]
机构
[1] Vienna Univ Technol, A-1040 Vienna, Austria
关键词
visualization; segmentation; blood vessel detection;
D O I
10.1109/VISUAL.2004.72
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Accurate estimation of vessel parameters is a prerequisite for automated visualization and analysis of healthy and diseased blood vessels. The objective of this research is to estimate the dimensions of lower extremity arteries, imaged by computed tomography (CT). These parameters are required to get a good quality visualization of healthy as well as diseased arteries using a visualization technique such as curved planar reformation (CPR). The vessel is modeled using an elliptical or cylindrical structure with specific dimensions, orientation and blood vessel mean density. The model separates two homogeneous regions: Its inner side represents a region of density for vessels, and its outer side a region for background. Taking into account the point spread function (PSF) of a CT scanner, a function is modeled with a Gaussian kernel, in order to smooth the vessel boundary in the model. A new strategy for vessel parameter estimation is presented. It stems from vessel model and model parameter optimization by a nonlinear optimization procedure, i.e., the Levenberg-Marquardt technique. The method provides center location, diameter and orientation of the vessel as well as blood and background mean density values. The method is tested on synthetic data and real patient data with encouraging results.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 50 条
  • [1] Some Comments on the Non-Linear Model Fitting
    Imre, Emoke
    Hegedus, Csaba
    Kovacs, Sandor
    2018 18TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND INFORMATICS (CINTI), 2018, : 173 - 178
  • [2] Two-fluid non-linear model for flow in catheterized blood vessels
    Sankar, D. S.
    Lee, Usik
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2008, 43 (07) : 622 - 631
  • [3] Parameter fitting for a non-linear viscoelastic material model
    Gotlih, K
    MAGIC WORLD OF TEXTILES, BOOK OF PROCEEDINGS, 2002, : 476 - 481
  • [4] Two-phase non-linear model for the flow through stenosed blood vessels
    Sankar, D. S.
    Lee, Usik
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2007, 21 (04) : 678 - 689
  • [5] Two-phase non-linear model for the flow through stenosed blood vessels
    D. S. Sankar
    Usik Lee
    Journal of Mechanical Science and Technology, 2007, 21 : 678 - 689
  • [6] NON-LINEAR REGRESSION MODEL FOR FITTING EXPERIMENTAL EMISSIONS DATA
    Ahrens, Denise
    Traub, Sebastian
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 3A, 2023,
  • [7] MODEL-FITTING, PARAMETER-ESTIMATION, LINEAR AND NON-LINEAR REGRESSION
    SAGNELLA, GA
    TRENDS IN BIOCHEMICAL SCIENCES, 1985, 10 (03) : 100 - 103
  • [8] Uncertainty analysis of linear least square fitting apply to non-linear model
    Arunthong, T.
    Thuenhan, S.
    Wongsripan, P.
    Chomkokard, S.
    Wongkokua, W.
    Jinuntuya, N.
    SIAM PHYSICS CONGRESS 2018 (SPC2018): A CREATIVE PATH TO SUSTAINABLE INNOVATION, 2018, 1144
  • [9] A NOTE ON NON-LINEAR CURVE FITTING
    WILSON, AL
    DOUGLAS, AW
    AMERICAN STATISTICIAN, 1969, 23 (04): : 37 - +
  • [10] FITTING AND INTERPRETING NON-LINEAR MODELS
    ROSS, GJS
    BIOMETRICS, 1980, 36 (01) : 185 - 185