The performance of BD FACSPresto™ for CD4 T-cell count, CD4% and hemoglobin concentration test in Ethiopia

被引:5
|
作者
Gebremicael, Gebremedhin [1 ]
Belay, Yohanes [1 ]
Girma, Fitsum [1 ]
Abreha, Yemane [1 ]
Gebreegziabxier, Atsbeha [1 ]
Tesfaye, Simret [1 ]
Messele, Zelalem [2 ]
Assefa, Yibeltal [1 ]
Bellete, Bahrie [2 ]
Kassa, Desta [1 ]
Vojnov, Lara [3 ]
机构
[1] Ethiopian Publ Hlth Inst, HIV & TB Dis Res Directorate, Addis Ababa, Ethiopia
[2] Clinton Hlth Access Initiat Inc, Addis Ababa, Ethiopia
[3] Clinton Hlth Access Initiat, Boston, MA USA
来源
PLOS ONE | 2017年 / 12卷 / 04期
关键词
LYMPHOCYTES;
D O I
10.1371/journal.pone.0176323
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction In Ethiopia, CD4+ T-cell counting is still required for all patients at baseline before antiretroviral therapy (ART) and to determine eligibility and follow-up of opportunistic infection prophylaxis. However, access to CD4+ T-cell count in rural health facilities remains a major challenge in Ethiopia like other resource-limited settings. Methodology Both capillary and venous blood was drawn from each of 325 study participant recruited in Addis Ababa and surroundings. The CD4+ T-cell count, CD4%, and hemoglobin (Hgb) were tested at one of the four study health facilities using capillary blood and BD FACSPresto (TM) device. These tests were also done at the national HIV reference laboratory, using venous blood with BD FACSCalibur (TM), Sysmex XT-1800i (TM), and BD FACSPresto (TM). Results BD FACSPresto (TM) had an absolute mean bias of -13.3 cells/mu l (-2.99%) and 28.3 cells/mu l (6.4%) using venous and capillary blood, respectively, compared with BD FACSCalibur (TM). The absolute CD4 assay on the BD FACSPresto (TM) had a regression coefficient (R-2) of 0.87 and 0.92 using capillary blood and venous blood samples, respectively, compared with BD FACSCalibur (TM). The percentage similarity of the BD FACSPresto (TM) using capillary and venous blood was 105.2% and 99.3%, respectively. The sensitivity of the FACSPresto (TM) using threshold of 500 cells/mu l for ART eligibility using capillary and venous blood was 87.9 and 94.3%, while the specificity was 91.4 and 83.8%, respectively. Furthermore, the BD FACSPresto (TM) had an absolute mean bias of -0.2 dl/mu l (0.0%) (95% LOA: -1.7, 1.3) and -0.59 dl/mu l (0.1%) (95% LOA: -1.49, 0.31) for Hgb using capillary and venous blood compared with the Sysmex XT-1800i (TM), respectively. Conclusion Our results showed acceptable agreement between the BD FACSPresto (TM) and BD FACS-Calibur (TM) for CD4+ T-cell counting and CD4%; and between the BD FACSPresto (TM) and Sysmex XT-1800i (TM) for measuring Hgb concentration.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The BD FACSPresto Point of Care CD4 Test Accurately Enumerates CD4+T Cell Counts
    Bwana, Priska
    Vojnov, Lara
    Adhiambo, Maureen
    Akinyi, Catherine
    Mwende, Joy
    Prescott, Marta
    Mwau, Matilu
    PLOS ONE, 2015, 10 (12):
  • [2] Beyond the Absence of CD4 T-Cell Count: A Novel Genetic CD4 T-Cell Deficiency Disorder With a Contingency Plan
    Routy, Jean-Pierre
    Isnard, Stephane
    JOURNAL OF INFECTIOUS DISEASES, 2021, 223 (04): : 547 - 549
  • [3] Performance evaluation of BD FACSPresto™ point of care CD4 analyzer to enumerate CD4 counts for monitoring HIV infected individuals in Nigeria
    Negedu-Momoh, Olubunmi Ruth
    Jegede, Feyisayo Ebenezer
    Yakubu, Ali
    Balogun, Oluseyi
    Abdullahi, Musa
    Badru, Titilope
    Oladele, Edward Adekola
    Agbakwuru, Chinedu
    Khamofu, Hadiza
    Torpey, Kwasi
    PLOS ONE, 2017, 12 (05):
  • [4] CD4 T-cell memory
    Stockinger, B
    Kassiotis, G
    Bourgeois, C
    SEMINARS IN IMMUNOLOGY, 2004, 16 (05) : 295 - 303
  • [5] The BD FACSPresto Point of Care CD4 Test accurately enumerates CD4+ T cell counts (vol 10, e0145586, 2015)
    Bwana, Priska
    Vojnov, Lara
    Adhiambo, Maureen
    Akinyi, Catherine
    Mwende, Joy
    Prescott, Marta
    Mwau, Matilu
    PLOS ONE, 2016, 11 (12):
  • [6] CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems
    Wade, Djibril
    Diaw, Papa Alassane
    Daneau, Geraldine
    Camara, Makhtar
    Dieye, Tandakha Ndiaye
    Mboup, Souleymane
    Kestens, Luc
    PLOS ONE, 2013, 8 (09):
  • [7] Idiopathic CD4 + T-cell lymphocytopenia
    Mukherjee, Aparna
    Lodha, Rakesh
    Kabra, S. K.
    INDIAN JOURNAL OF PEDIATRICS, 2009, 76 (04): : 430 - 432
  • [8] CD4 T-cell death in AIDS
    Bradbury, Jane
    LANCET INFECTIOUS DISEASES, 2014, 14 (02): : 106 - 106
  • [9] The potential of CD4 T-cell memory
    McKinstry, K. Kai
    Strutt, Tara M.
    Swain, Susan L.
    IMMUNOLOGY, 2010, 130 (01) : 1 - 9
  • [10] Validation of the BD FACSPresto system for the measurement of CD4 T-lymphocytes and hemoglobin concentration in HIV-negative and HIV-positive subjects
    Xiaofan Lu
    Hanxiao Sun
    Haicong Li
    Wei Xia
    Hao Wu
    Daihong Chen
    Meiyu Tan
    Shijun Yu
    Tong Zhang
    Huiming Sheng
    Zhaoqin Zhu
    Scientific Reports, 10