Green roof performance potential in cold and wet regions

被引:49
|
作者
Johannessen, Birgitte Gisvold [1 ]
Hanslin, Hans Martin [2 ]
Muthanna, Tone Merete [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Civil & Environm Engn, N-7491 Trondheim, Norway
[2] Norwegian Inst Bioecon Res, Dept Urban Greening & Environm Engn, POB 115, NO-1431 As, Norway
关键词
Extensive green roofs; Evapotranspiration; Stormwater; Retention; Drought; Cold climate; EXTENSIVE LIVING ROOF; HYDROLOGICAL PERFORMANCE; SUBSTRATE DEPTH; EVAPOTRANSPIRATION ESTIMATION; INITIAL GROWTH; LONG-TERM; WATER; RETENTION; VEGETATION; TOLERANCE;
D O I
10.1016/j.ecoleng.2017.06.011
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Extensive green roofs have become a frequently used option for stormwater retention across many different climates including cold and wet regions. Despite the extensive documentation of green roof technology for stormwater management, the knowledge about their function and potential use in wet and cold regions is deficient. Using historic data on daily temperature and precipitation in a green roof water balance model coupled with the Oudin model of evapotranspiration (ET), we evaluated the effects of maximum green roof storage capacities (S-max) and ET on stormwater retention along climatic gradients in Northern Europe. Large differences in potential annual stormwater retention were found between locations, driven by differences in temperature and precipitation amounts. Highest retention in absolute values was found for the wettest locations, while the warmest and driest locations showed highest retention in percentage of annual precipitation (up to 58% compared to 17% for the lower range). All locations showed a considerable retention of stormwater during summer, ranging from 52% to 91%. Storage capacities accepting drought conditions once every 3.3-3.9 year were found to be about 25 mm in the cold and wet locations increasing to 40-50 mm in the warmer and drier locations. Corresponding storage capacities to prevent wilting of non -succulent vegetation was on average a factor of 1.5 larger (not including Sheffield and Malmo). Annual retention increased both with an increase in plant water use (specific crop factors, K-c) and with an increase in Smax, but was found to be more sensitive to changes in K-c than to changes in S-max. Hence, ET was the limiting factor for green roof retention capacity in the cold and wet locations, but relatively large changes in evapotranspiration would be needed to have an impact on retention. The potential to use vegetation with higher water use to better restore the storage capacity between storm-events in these regions was however limited by the risk of permanent wilting of non-succulent vegetation, even on the wettest locations. A considerable increase in roof storage capacity and substrate thickness would be required to reduce this risk; still the increase in stormwater retention would be marginal. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 50 条
  • [1] Experimental investigation on the thermal performance of a vertical greening system with green roof in wet and cold climates during winter
    Xing, Qingwei
    Hao, Xiaoli
    Lin, Yaolin
    Tan, Hang
    Yang, Ke
    ENERGY AND BUILDINGS, 2019, 183 : 105 - 117
  • [2] Roof design in regions of snow and cold
    Mackinlay, I
    Flood, R
    Heidrich, A
    SNOW ENGINEERING: RECENT ADVANCES AND DEVELOPMENTS, 2000, : 213 - 224
  • [3] Temporal variations in the potential hydrological performance of extensive green roof systems
    De-Ville, Simon
    Menon, Manoj
    Stovin, Virginia
    JOURNAL OF HYDROLOGY, 2018, 558 : 564 - 578
  • [4] Cold regions of the roof on the building energy consumption impact
    Ma, Honglei
    Wang, Jianfeng
    Ji, Min
    ADVANCED RESEARCH ON ADVANCED STRUCTURE, MATERIALS AND ENGINEERING, 2012, 382 : 215 - +
  • [5] A Longitudinal Microcosm Study on the Effects of Ageing on Potential Green Roof Hydrological Performance
    De-Ville, Simon
    Menon, Manoj
    Jia, Xiaodong
    Stovin, Virginia
    WATER, 2018, 10 (06)
  • [6] Energy performance assessment on vertical greening systems with green roof in hot summer and cold winter regions based on long-term experimental data
    Song, Xunxing
    Hao, Xiaoli
    Lin, Yaolin
    Ai, Guole
    Yin, Wei
    Hu, Jinhua
    Zhang, Shaobo
    URBAN FORESTRY & URBAN GREENING, 2025, 103
  • [7] Seismic Performance of a Green Roof Structure
    Tam, Svetlana
    Wong, Jenna
    SUSTAINABILITY, 2021, 13 (08)
  • [8] Defining green roof detention performance
    Stovin, Virginia
    Vesuviano, Gianni
    De-Ville, Simon
    URBAN WATER JOURNAL, 2017, 14 (06) : 574 - 588
  • [9] Evaluating green roof energy performance
    Sonne, J
    ASHRAE JOURNAL, 2006, 48 (02) : 59 - 61
  • [10] The Research of POE System and Method of Urban Green Residential Environmental Performance in Severe Cold and Cold Regions
    Yu, Liang
    Gao, Wei
    Sun, Zhenbo
    Ding, Ran
    Feng, Guohui
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 107 - 113